AETHER-2011 (part4)
Add getting started links to main page
Mark P4-based fabric & UPF as beta features for 1.5
Fix BOM -> BoM capitalization
Change-Id: I5aa5defa2124c5be93b7f06ced543ee85f8e9380
diff --git a/edge_deployment/overview.rst b/edge_deployment/overview.rst
index c78e99c..216740c 100644
--- a/edge_deployment/overview.rst
+++ b/edge_deployment/overview.rst
@@ -79,9 +79,9 @@
BESS-based Network Topology
---------------------------
-The :doc:`Software-only BESS UPF
-</edge_deployment/bess_upf_deployment>`, which can be used for deployments that
-do not have P4 switching hardware.
+The :doc:`Software-only BESS UPF </edge_deployment/bess_upf_deployment>`, is
+supported for production use in the Aether 1.5 release. This UPF can be used
+for deployments that do not have P4 switching hardware.
.. image:: images/edge_mgmt_only.svg
:alt: BESS network topology
@@ -97,6 +97,12 @@
P4-based Network Topology
-------------------------
+.. note::
+
+ The P4-based SD-Fabric UPF is an advanced feature and is of beta quality in
+ the Aether 1.5 release. It requires one or more P4-capable switches using
+ the Tofino chipset.
+
If only a single P4 switch is used, the :doc:`Simple
<trellis:supported-topology>` topology can be used, but provides no network
redundancy:
@@ -312,11 +318,11 @@
Some quantities are dependent on other quantities - for example, the number of
DAC cables frequently depends on the number of servers in use.
-These BOMs do not include UE devices. It's recommended that the testing
+These BoMs do not include UE devices. It's recommended that the testing
hardware given above be added to every BoM for monitoring purposes.
-BESS UPF Testing BOM
+BESS UPF Testing BoM
""""""""""""""""""""
The following is the minimum BoM required to run Aether with the BESS UPF.
@@ -332,7 +338,7 @@
Sufficient Cat6 Network Cabling Between all equipment
============ ===================== ===============================================
-P4 UPF Testing BOM
+P4 UPF Testing BoM
""""""""""""""""""
============ ===================== ===============================================
@@ -351,7 +357,7 @@
Sufficient Cat6 Network Cabling Between all equipment
============ ===================== ===============================================
-P4 UPF Paired Leaves BOM
+P4 UPF Paired Leaves BoM
""""""""""""""""""""""""
============ ===================== ===============================================
@@ -372,7 +378,7 @@
============ ===================== ===============================================
-P4 UPF 2x2 Leaf Spine Fabric BOM
+P4 UPF 2x2 Leaf Spine Fabric BoM
""""""""""""""""""""""""""""""""
============ ===================== ===============================================