Add Aether files and directories from helm-charts

Change-Id: I2edb76ebbf8f1da147f760c0fa4618219c49b6cc
diff --git a/omec/omec-data-plane/values.yaml b/omec/omec-data-plane/values.yaml
new file mode 100644
index 0000000..dd3ee9a
--- /dev/null
+++ b/omec/omec-data-plane/values.yaml
@@ -0,0 +1,86 @@
+# Copyright 2018-present Open Networking Foundation
+# Copyright 2018 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+images:
+  tags:
+    init: docker.io/omecproject/pod-init:1.0.0
+    omecCni: docker.io/omecproject/omec-cni:1.0.0
+    spgwu: docker.io/omecproject/ngic-dp:central-cp-multi-upfs-latest-debug
+    depCheck: quay.io/stackanetes/kubernetes-entrypoint:v0.3.1
+  pullPolicy: IfNotPresent
+
+nodeSelectors:
+  enabled: false
+  spgwu:
+    label: omec-dp
+    value: enabled
+
+resources:
+  enabled: true
+  spgwu:
+    requests:
+      cpu: 4
+      memory: 8Gi
+    limits:
+      cpu: 4
+      memory: 8Gi
+
+config:
+  coreDump:
+    enabled: false
+    path: /tmp/coredump
+  sriov:
+    enabled: true
+  spgwu:
+    # Provide the S1U and SGI networks facing device name and IP address
+    s1u:
+      device: s1u-net
+      ip: 192.168.251.3/24
+    sgi:
+      device: sgi-net
+      ip: 192.168.250.3/24
+    # Note that zmq is used for cp-dp commmunication when multiple UPFs is set
+    # Otherwise, direct UDP communication is used
+    # TODO: unify cp-dp comm to ZMQ for both multi and single UPF scenario
+    multiUpfs: true
+    cpComm:
+      # IMPORTANT: when you deploy CP and DP to separate clusters, enable nodePort
+      # from both cpComm(omec-control-plane) and dpComm(omec-data-plane) and
+      # set "addr" to remote cluster's entry node IP and
+      # "port" to cpComm.nodePort.port value configured in omec-control-plane.
+      addr: spgwc-headless
+      port: 21
+    dpComm:
+      nodePort:
+        enabled: false
+        port: 30020
+      port: 20
+    # Set "--no-pci --vdev eth_af_packet0,iface=s1u-net --vdev eth_af_packet1,iface=sgi-net"
+    # when sriov is disabled
+    devices: ""
+    dpName: "onf-menlo"
+
+networks:
+  cniPlugin: vfioveth
+  # Currently, we do not support dynamic IP allocation
+  ipam: static
+  s1u:
+    subnet: 192.168.251.0/24
+    mask: 255.255.255.0
+    gateway: 192.168.251.254
+  sgi:
+    subnet: 192.168.250.0/24
+    mask: 255.255.255.0
+    gateway: 192.168.250.250