Add Aether files and directories from helm-charts
Change-Id: I2edb76ebbf8f1da147f760c0fa4618219c49b6cc
diff --git a/omec/omec-data-plane/values.yaml b/omec/omec-data-plane/values.yaml
new file mode 100644
index 0000000..dd3ee9a
--- /dev/null
+++ b/omec/omec-data-plane/values.yaml
@@ -0,0 +1,86 @@
+# Copyright 2018-present Open Networking Foundation
+# Copyright 2018 Intel Corporation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+images:
+ tags:
+ init: docker.io/omecproject/pod-init:1.0.0
+ omecCni: docker.io/omecproject/omec-cni:1.0.0
+ spgwu: docker.io/omecproject/ngic-dp:central-cp-multi-upfs-latest-debug
+ depCheck: quay.io/stackanetes/kubernetes-entrypoint:v0.3.1
+ pullPolicy: IfNotPresent
+
+nodeSelectors:
+ enabled: false
+ spgwu:
+ label: omec-dp
+ value: enabled
+
+resources:
+ enabled: true
+ spgwu:
+ requests:
+ cpu: 4
+ memory: 8Gi
+ limits:
+ cpu: 4
+ memory: 8Gi
+
+config:
+ coreDump:
+ enabled: false
+ path: /tmp/coredump
+ sriov:
+ enabled: true
+ spgwu:
+ # Provide the S1U and SGI networks facing device name and IP address
+ s1u:
+ device: s1u-net
+ ip: 192.168.251.3/24
+ sgi:
+ device: sgi-net
+ ip: 192.168.250.3/24
+ # Note that zmq is used for cp-dp commmunication when multiple UPFs is set
+ # Otherwise, direct UDP communication is used
+ # TODO: unify cp-dp comm to ZMQ for both multi and single UPF scenario
+ multiUpfs: true
+ cpComm:
+ # IMPORTANT: when you deploy CP and DP to separate clusters, enable nodePort
+ # from both cpComm(omec-control-plane) and dpComm(omec-data-plane) and
+ # set "addr" to remote cluster's entry node IP and
+ # "port" to cpComm.nodePort.port value configured in omec-control-plane.
+ addr: spgwc-headless
+ port: 21
+ dpComm:
+ nodePort:
+ enabled: false
+ port: 30020
+ port: 20
+ # Set "--no-pci --vdev eth_af_packet0,iface=s1u-net --vdev eth_af_packet1,iface=sgi-net"
+ # when sriov is disabled
+ devices: ""
+ dpName: "onf-menlo"
+
+networks:
+ cniPlugin: vfioveth
+ # Currently, we do not support dynamic IP allocation
+ ipam: static
+ s1u:
+ subnet: 192.168.251.0/24
+ mask: 255.255.255.0
+ gateway: 192.168.251.254
+ sgi:
+ subnet: 192.168.250.0/24
+ mask: 255.255.255.0
+ gateway: 192.168.250.250