[VOL-4395] Added support to enable/disable per-test voltha logging in bbsim based periodic jobs

Change-Id: I26f0855866702e77d97da15bfe27a8cf66b84acf
diff --git a/jjb/pipeline/voltha/master/bbsim-tests.groovy b/jjb/pipeline/voltha/master/bbsim-tests.groovy
index b2f0220..2423d23 100755
--- a/jjb/pipeline/voltha/master/bbsim-tests.groovy
+++ b/jjb/pipeline/voltha/master/bbsim-tests.groovy
@@ -23,7 +23,7 @@
 
 def clusterName = "kind-ci"
 
-def execute_test(testTarget, workflow, teardown, testSpecificHelmFlags = "") {
+def execute_test(testTarget, workflow, testLogging, teardown, testSpecificHelmFlags = "") {
   def infraNamespace = "default"
   def volthaNamespace = "voltha"
   def robotLogsDir = "RobotLogs"
@@ -108,33 +108,14 @@
     }
   }
   stage('Run test ' + testTarget + ' on ' + workflow + ' workFlow') {
-    // start logging
-    sh """
-    mkdir -p $WORKSPACE/${testTarget}-components
-    _TAG=kail-${workflow} kail -n ${infraNamespace} -n ${volthaNamespace} > $WORKSPACE/${testTarget}-components/onos-voltha-combined.log &
-    """
     sh """
     mkdir -p $WORKSPACE/${robotLogsDir}/${testTarget}-robot
     export ROBOT_MISC_ARGS="-d $WORKSPACE/${robotLogsDir}/${testTarget}-robot "
-    ROBOT_MISC_ARGS+="-v ONOS_SSH_PORT:30115 -v ONOS_REST_PORT:30120 -v NAMESPACE:${volthaNamespace} -v INFRA_NAMESPACE:${infraNamespace}"
+    ROBOT_MISC_ARGS+="-v ONOS_SSH_PORT:30115 -v ONOS_REST_PORT:30120 -v NAMESPACE:${volthaNamespace} -v INFRA_NAMESPACE:${infraNamespace} -v container_log_dir:$WORKSPACE/${robotLogsDir}/${testTarget}-robot -v logging:${testLogging}"
     export KVSTOREPREFIX=voltha/voltha_voltha
 
     make -C $WORKSPACE/voltha-system-tests ${testTarget} || true
     """
-    // stop logging
-    sh """
-      P_IDS="\$(ps e -ww -A | grep "_TAG=kail-${workflow}" | grep -v grep | awk '{print \$1}')"
-      if [ -n "\$P_IDS" ]; then
-        echo \$P_IDS
-        for P_ID in \$P_IDS; do
-          kill -9 \$P_ID
-        done
-      fi
-      cd $WORKSPACE/${testTarget}-components/
-      rm onos-voltha-combined.log.gz || true
-      gzip -k onos-voltha-combined.log
-      rm onos-voltha-combined.log
-    """
     getPodsInfo("$WORKSPACE/${testTarget}-components")
   }
 }
@@ -251,8 +232,9 @@
               def workflow = test["workflow"]
               def flags = test["flags"]
               def teardown = test["teardown"].toBoolean()
-              println "Executing test ${target} on workflow ${workflow} with extra flags ${flags}"
-              execute_test(target, workflow, teardown, flags)
+              def logging = test["logging"]
+              println "Executing test ${target} on workflow ${workflow} with logging ${logging} and extra flags ${flags}"
+              execute_test(target, workflow, logging, teardown, flags)
             }
           }
         }
diff --git a/jjb/pipeline/voltha/voltha-2.8/bbsim-tests.groovy b/jjb/pipeline/voltha/voltha-2.8/bbsim-tests.groovy
index ef6964b..411024b 100755
--- a/jjb/pipeline/voltha/voltha-2.8/bbsim-tests.groovy
+++ b/jjb/pipeline/voltha/voltha-2.8/bbsim-tests.groovy
@@ -23,7 +23,7 @@
 
 def clusterName = "kind-ci"
 
-def execute_test(testTarget, workflow, teardown, testSpecificHelmFlags = "") {
+def execute_test(testTarget, workflow, testLogging, teardown, testSpecificHelmFlags = "") {
   def infraNamespace = "default"
   def volthaNamespace = "voltha"
   def robotLogsDir = "RobotLogs"
@@ -108,33 +108,14 @@
     }
   }
   stage('Run test ' + testTarget + ' on ' + workflow + ' workFlow') {
-    // start logging
-    sh """
-    mkdir -p $WORKSPACE/${testTarget}-components
-    _TAG=kail-${workflow} kail -n ${infraNamespace} -n ${volthaNamespace} > $WORKSPACE/${testTarget}-components/onos-voltha-combined.log &
-    """
     sh """
     mkdir -p $WORKSPACE/${robotLogsDir}/${testTarget}-robot
     export ROBOT_MISC_ARGS="-d $WORKSPACE/${robotLogsDir}/${testTarget}-robot "
-    ROBOT_MISC_ARGS+="-v ONOS_SSH_PORT:30115 -v ONOS_REST_PORT:30120 -v INFRA_NAMESPACE:${infraNamespace}"
+    ROBOT_MISC_ARGS+="-v ONOS_SSH_PORT:30115 -v ONOS_REST_PORT:30120 -v INFRA_NAMESPACE:${infraNamespace} -v container_log_dir:$WORKSPACE/${robotLogsDir}/${testTarget}-robot -v logging:${testLogging}"
     export KVSTOREPREFIX=voltha/voltha_voltha
 
     make -C $WORKSPACE/voltha-system-tests ${testTarget} || true
     """
-    // stop logging
-    sh """
-      P_IDS="\$(ps e -ww -A | grep "_TAG=kail-${workflow}" | grep -v grep | awk '{print \$1}')"
-      if [ -n "\$P_IDS" ]; then
-        echo \$P_IDS
-        for P_ID in \$P_IDS; do
-          kill -9 \$P_ID
-        done
-      fi
-      cd $WORKSPACE/${testTarget}-components/
-      rm onos-voltha-combined.log.gz || true
-      gzip -k onos-voltha-combined.log
-      rm onos-voltha-combined.log
-    """
     getPodsInfo("$WORKSPACE/${testTarget}-components")
   }
 }
@@ -251,8 +232,9 @@
               def workflow = test["workflow"]
               def flags = test["flags"]
               def teardown = test["teardown"].toBoolean()
-              println "Executing test ${target} on workflow ${workflow} with extra flags ${flags}"
-              execute_test(target, workflow, teardown, flags)
+              def logging = test["logging"]
+              println "Executing test ${target} on workflow ${workflow} with logging ${logging} and extra flags ${flags}"
+              execute_test(target, workflow, logging, teardown, flags)
             }
           }
         }
diff --git a/jjb/voltha-e2e.yaml b/jjb/voltha-e2e.yaml
index 5038059..4e61ecd 100755
--- a/jjb/voltha-e2e.yaml
+++ b/jjb/voltha-e2e.yaml
@@ -31,22 +31,27 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-alarms-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-failurescenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-errorscenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: onos-ha-test
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-test-bbsim-new-olt-app'
@@ -58,22 +63,27 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-alarms-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-failurescenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-errorscenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: onos-ha-test
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multiple-olts-test-bbsim'
@@ -86,18 +96,22 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiolt-failurescenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiolt-errorscenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiolt-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-test-bbsim-2.8'
@@ -109,18 +123,22 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-alarms-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-failurescenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-errorscenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multiple-olts-test-bbsim-2.8'
@@ -134,18 +152,22 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiolt-failurescenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiolt-errorscenarios
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiolt-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multi-uni-test-bbsim'
@@ -157,14 +179,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiuni-failurescenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiuni-errorscenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim'
@@ -177,14 +202,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiuni-multiolt-failurescenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiuni-multiolt-errorscenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
           timeout: 180
 
       - 'voltha-periodic-test':
@@ -198,14 +226,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiuni-failurescenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiuni-errorscenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim-2.8'
@@ -219,14 +250,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: bbsim-multiuni-multiolt-failurescenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: bbsim-multiuni-multiolt-errorscenarios-att
               workflow: att
               flags: ""
               teardown: false
+              logging: True
           timeout: 180
 
       # openonu Go periodic tests
@@ -241,62 +275,77 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: mib-upload-templating-openonu-go-adapter-test
               workflow: att
               flags: "--set pon=2,onu=2,controlledActivation=only-onu"
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-passed-test
               workflow: att
               flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s"
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-failed-test
               workflow: att
               flags: "--set omci_response_rate=7"
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-openonu-go-test-bbsim-new-olt-app'
@@ -309,62 +358,77 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: mib-upload-templating-openonu-go-adapter-test
               workflow: att
               flags: "--set pon=2,onu=2,controlledActivation=only-onu"
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-passed-test
               workflow: att
               flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s"
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-failed-test
               workflow: att
               flags: "--set omci_response_rate=7"
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-openonu-go-test-bbsim-2.8'
@@ -377,50 +441,62 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: mib-upload-templating-openonu-go-adapter-test
               workflow: att
               flags: "--set pon=2,onu=2,controlledActivation=only-onu"
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-passed-test
               workflow: att
               flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s"
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-failed-test
               workflow: att
               flags: "--set omci_response_rate=7"
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'patchset-voltha-openonu-go-test-bbsim'
@@ -435,62 +511,77 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: mib-upload-templating-openonu-go-adapter-test
               workflow: att
               flags: "--set pon=2,onu=2,controlledActivation=only-onu"
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-passed-test
               workflow: att
               flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s"
               teardown: true
+              logging: True
             - target: openonu-go-adapter-omci-hardening-failed-test
               workflow: att
               flags: "--set omci_response_rate=7"
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-multiple-olts-openonu-go-test-bbsim'
@@ -503,50 +594,62 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-multiolt-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           time-trigger: "H H/12 * * *"
 
       - 'voltha-periodic-test':
@@ -561,38 +664,47 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           time-trigger: "H H/23 * * *"
 
       - 'voltha-periodic-test':
@@ -608,50 +720,62 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t4gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: 1t8gem-openonu-go-adapter-multi-olt-test
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: reconcile-openonu-go-adapter-multi-olt-test-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-omci-get-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
-             - target: voltha-onu-flows-check-multiolt-kind-att
+              logging: True
+            - target: voltha-onu-flows-check-multiolt-kind-att
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-onu-flows-check-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           olts: 2
 
       - 'voltha-periodic-test':
@@ -665,14 +789,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           timeout: 140
 
       - 'voltha-periodic-test':
@@ -688,14 +815,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           timeout: 140
 
       - 'voltha-periodic-test':
@@ -710,14 +840,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-single-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           timeout: 140
 
       - 'voltha-periodic-test':
@@ -732,14 +865,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           time-trigger: "H H/23 * * *"
 
       - 'voltha-periodic-test':
@@ -755,14 +891,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           olts: 2
           timeout: 180
 
@@ -779,14 +918,17 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-dt
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
             - target: voltha-pm-data-multiolt-kind-tt
               workflow: tt
               flags: ""
               teardown: true
+              logging: True
           time-trigger: "H H/23 * * *"
 
       - 'voltha-periodic-test':
@@ -799,6 +941,7 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-test-DMI-2.8'
@@ -810,6 +953,7 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-etcd-test'
@@ -822,6 +966,7 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-etcd-test-2.8'
@@ -835,6 +980,7 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-sanity-test-multi-runs'
@@ -846,22 +992,27 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'periodic-voltha-sanity-test-multi-runs-2.8'
@@ -873,22 +1024,27 @@
               workflow: att
               flags: ""
               teardown: true
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
             - target: sanity-kind
               workflow: att
               flags: ""
               teardown: false
+              logging: True
 
       - 'voltha-periodic-test':
           name: 'nightly-voltha-DTflow-sanity-test'
@@ -901,6 +1057,7 @@
               workflow: dt
               flags: ""
               teardown: true
+              logging: True
 
       # ATT Per-patchset Pod builds on Tucson pod (master)
       - 'verify_physical_voltha_patchset_auto':
@@ -1009,6 +1166,7 @@
       #     workflow: att
       #     flags: ""
       #     teardown: true
+      #     logging: True
       - text:
           name: testTargets
           default: '{testTargets}'
@@ -1112,14 +1270,17 @@
         workflow: att
         flags: ""
         teardown: true
+        logging: True
       - target: sanity-kind-dt
         workflow: dt
         flags: ""
         teardown: true
+        logging: True
       - target: sanity-kind-tt
         workflow: tt
         flags: ""
         teardown: true
+        logging: True
 
     description: |
       <!-- Managed by Jenkins Job Builder -->