1. f2cf13e [VOL-3461] Lowering flow chunk size because of lager flow size in TT workflow by Andrea Campanella · 4 years, 4 months ago
  2. cd40201 [VOL-3199] Added support for dynamic enable/disable of Trace Publishing by Girish Kumar · 4 years, 4 months ago
  3. 9a2c9b0 [VOL-3228] device-id logging consistancy by divyadesai · 4 years, 4 months ago
  4. be2ea8a [VOL-3424] Switch completely to Context based Logger instance by Girish Kumar · 4 years, 4 months ago
  5. 01e0c63 [VOL-3141] Created Span for various Openflow and Ofagent operations by Girish Kumar · 4 years, 5 months ago
  6. 2ed051b [VOL-3196] Enhanced gRPC interfaces to create and propagate Span for log correlation by Girish Kumar · 4 years, 5 months ago
  7. f6611b8 [VOL-3375]Remove field pkg from log statements by Rohan Agrawal · 4 years, 5 months ago
  8. 07e9494 [VOL-3355] Return MeterMod Error on meter faliure by Andrea Campanella · 4 years, 5 months ago
  9. c32d993 [VOL-3187]Pass Context down the execution call hierarchy across ofagent codebase by Rohan Agrawal · 4 years, 6 months ago
  10. 3d955ef [VOL-3242] handle each incoming messages with a go routine by Andrea Campanella · 4 years, 6 months ago v1.2.5
  11. 082a701 VOL-3211 Flow Remove following subscriber remove not propagated to adapter by Esin Karaman · 4 years, 6 months ago v1.2.4
  12. 322c308 [VOL-3242] Sending FlowRemoved message once the FlowDeleteStrict message has been successfully sent to VOLTHA by Matteo Scandolo · 4 years, 6 months ago v1.2.2
  13. 9b0ac0a VOL-3121 - Replaced usage of LogicalDevice.Ports with ListLogicalDevicePorts(). by Kent Hagerman · 4 years, 7 months ago
  14. 256266d [VOL-3143] Optimize and test ofAgent response chunking by Matteo Scandolo · 4 years, 7 months ago
  15. e23b758 [VOL-3108] Sending multipart messages when size is bigger than 64KB by Matteo Scandolo · 4 years, 7 months ago
  16. 3e2b2ce [VOL-3066] Ofagent must support VLAN_PCP and ETH_DST fields by Gamze Abaka · 4 years, 8 months ago
  17. 828908c Change goloxi dependency to opencord/goloxi. by Jonathan Hart · 4 years, 8 months ago
  18. 60c5d77 Support group mods and group stats requests. by Jonathan Hart · 4 years, 9 months ago
  19. f8ce7d2 VOL-2894 - reference the voltha GRPC end point via a holder by David Bainbridge · 4 years, 9 months ago
  20. 4b110f6 Support connecting to multiple OpenFlow controllers by Jonathan Hart · 4 years, 10 months ago
  21. e9d7617 [VOL-2694] Use package specific logger instance in all log statements by Girish Kumar · 4 years, 9 months ago
  22. 81bb7ba [VOL-2538] Logging - Implement dynamic log levels in ofagent by divyadesai · 4 years, 10 months ago
  23. 3034262 [VOL-2692] Returning FlowMod error to controller by Andrea Campanella · 4 years, 10 months ago
  24. 91c4e4e Refactoring logs with correct messages by Andrea Campanella · 4 years, 10 months ago
  25. 7fe70f7 [VOL-2552][VOL-2517] Handling 4096 as transaprent VLAN by Don Newton · 4 years, 10 months ago v1.1.2
  26. 3243ee5 Updated tools version to 2.0.0 by Kent Hagerman · 4 years, 10 months ago
  27. cac73ac VOL-2625 - fix SCA issues by David K. Bainbridge · 4 years, 10 months ago
  28. 9cb404e VOL-2518 - reconnect to voltha on disconnect by David K. Bainbridge · 5 years ago
  29. e6d95f6 optimiztion of buffer usage by David K. Bainbridge · 5 years ago
  30. 0b3f648 VOL-2511 - copy the read buffer for processing by David K. Bainbridge · 5 years ago
  31. aea73cd VOL-2509 - upodate to use v3 protobufs by David K. Bainbridge · 5 years ago
  32. ac0455d tweak client by Don Newton · 5 years ago
  33. 5537626 VOL-2487 - correct meter state size calculation by David K. Bainbridge · 5 years ago
  34. 157bdab WIP - Suggesting changes (take2) by David K. Bainbridge · 5 years ago