SEBA-401: Reformat olt-service xproto
Change-Id: I82bad470434271e73d4c5a9808ef095260078b70
diff --git a/xos/synchronizer/models/volt.xproto b/xos/synchronizer/models/volt.xproto
index 4155ceb..778db60 100644
--- a/xos/synchronizer/models/volt.xproto
+++ b/xos/synchronizer/models/volt.xproto
@@ -7,92 +7,222 @@
option kind = "vOLT";
option description = "OLT Access Service";
- required string voltha_url = 1 [help_text = "The Voltha API address. By default voltha.voltha.svc.cluster.local", default = "voltha.voltha.svc.cluster.local", max_length = 254, db_index = False];
- required int32 voltha_port = 2 [help_text = "The Voltha API port. By default 8882", default=8882, db_index = False];
- required string voltha_user = 3 [help_text = "The Voltha username. By default voltha", default="voltha", max_length = 254, db_index = False];
- required string voltha_pass = 4 [help_text = "The Voltha password. By default admin", default="admin", max_length = 254, db_index = False];
- required string onos_voltha_url = 5 [help_text = "The ONOS Voltha address. By default onos-voltha-ui.voltha.svc.cluster.local", default="onos-voltha-ui.voltha.svc.cluster.local", max_length = 254, db_index = False];
- required int32 onos_voltha_port = 6 [help_text = "The Voltha API port. By default 8181", default=8181, db_index = False];
- required string onos_voltha_user = 7 [help_text = "The ONOS Voltha username. By default sdn", max_length = 254, default="onos", db_index = False];
- required string onos_voltha_pass = 8 [help_text = "The ONOS Voltha password. By default rocks", max_length = 254, default="rocks", db_index = False];
+ required string voltha_url = 1 [
+ help_text = "The Voltha API address. By default voltha.voltha.svc.cluster.local",
+ db_index = False,
+ default = "voltha.voltha.svc.cluster.local",
+ max_length = 254];
+ required int32 voltha_port = 2 [
+ help_text = "The Voltha API port. By default 8882",
+ db_index = False,
+ default = 8882];
+ required string voltha_user = 3 [
+ help_text = "The Voltha username. By default voltha",
+ db_index = False,
+ default = "voltha",
+ max_length = 254];
+ required string voltha_pass = 4 [
+ help_text = "The Voltha password. By default admin",
+ db_index = False,
+ default = "admin",
+ max_length = 254];
+ required string onos_voltha_url = 5 [
+ help_text = "The ONOS Voltha address. By default onos-voltha-ui.voltha.svc.cluster.local",
+ db_index = False,
+ default = "onos-voltha-ui.voltha.svc.cluster.local",
+ max_length = 254];
+ required int32 onos_voltha_port = 6 [
+ help_text = "The Voltha API port. By default 8181",
+ db_index = False,
+ default = 8181];
+ required string onos_voltha_user = 7 [
+ help_text = "The ONOS Voltha username. By default sdn",
+ max_length = 254,
+ db_index = False,
+ default = "onos"];
+ required string onos_voltha_pass = 8 [
+ help_text = "The ONOS Voltha password. By default rocks",
+ max_length = 254,
+ db_index = False,
+ default = "rocks"];
}
message OLTDevice (XOSBase){
option verbose_name = "OLT Device";
option description="Represents a physical OLT device";
- required manytoone volt_service->VOLTService:volt_devices = 1:1001 [help_text = "VOLTService that owns this OLT", db_index = True];
- optional string name = 2 [help_text = "Human-readable name of device", max_length = 254, db_index = False, unique = True];
- required string device_type = 3 [help_text = "Phyiscal Device Type", default = "openolt", max_length = 254, db_index = False];
- optional string host = 4 [help_text = "IP Address of physical OLT Device", max_length = 254, db_index = False];
- optional int32 port = 5 [help_text = "Port Number of physical OLT Device", db_index = False, unique_with = "host"];
- optional string mac_address = 6 [help_text = "Mac address of physical OLT Device", db_index = False];
+ required manytoone volt_service->VOLTService:volt_devices = 1:1001 [
+ help_text = "VOLTService that owns this OLT",
+ db_index = True];
+ optional string name = 2 [
+ help_text = "Human-readable name of device",
+ db_index = False,
+ max_length = 254,
+ unique = True];
+ required string device_type = 3 [
+ help_text = "Phyiscal Device Type",
+ db_index = False,
+ default = "openolt",
+ max_length = 254];
+ optional string host = 4 [
+ help_text = "IP Address of physical OLT Device",
+ db_index = False,
+ max_length = 254];
+ optional int32 port = 5 [
+ help_text = "Port Number of physical OLT Device",
+ db_index = False,
+ unique_with = "host"];
+ optional string mac_address = 6 [
+ help_text = "Mac address of physical OLT Device",
+ db_index = False];
- optional string serial_number = 9 [help_text = "Serial Number", db_index = False];
- optional string device_id = 10 [help_text = "Voltha Device ID", db_index = False, feedback_state = True];
- optional string admin_state = 11 [help_text = "admin state, whether OLT should be enabled", choices = "(('DISABLED', 'DISABLED'), ('ENABLED', 'ENABLED'))", default="ENABLED", db_index = False];
- optional string oper_status = 12 [help_text = "operational status, whether OLT is active", db_index = False, feedback_state = True];
- optional string of_id = 13 [help_text = "Logical device openflow id", db_index = False, feedback_state = True];
- optional string dp_id = 14 [help_text = "Logical device datapath id", db_index = False];
+ optional string serial_number = 9 [
+ help_text = "Serial Number",
+ db_index = False];
+ optional string device_id = 10 [
+ help_text = "Voltha Device ID",
+ db_index = False,
+ feedback_state = True];
+ optional string admin_state = 11 [
+ help_text = "admin state, whether OLT should be enabled",
+ choices = "(('DISABLED', 'DISABLED'), ('ENABLED', 'ENABLED'))",
+ db_index = False,
+ default = "ENABLED"];
+ optional string oper_status = 12 [
+ help_text = "operational status, whether OLT is active",
+ db_index = False,
+ feedback_state = True];
+ optional string of_id = 13 [
+ help_text = "Logical device openflow id",
+ db_index = False,
+ feedback_state = True];
+ optional string dp_id = 14 [
+ help_text = "Logical device datapath id",
+ db_index = False];
- required string uplink = 15 [help_text = "uplink port, exposed via sadis", db_index = False];
- required string driver = 16 [help_text = "DEPRECATED", default="voltha", db_index = False]; // Used to be sent to ONOS, now unused.
+ required string uplink = 15 [
+ help_text = "uplink port, exposed via sadis",
+ db_index = False];
+ required string driver = 16 [
+ help_text = "DEPRECATED",
+ db_index = False,
+ default = "voltha"]; // Used to be sent to ONOS, now unused.
- optional string switch_datapath_id = 17 [help_text = "Fabric switch to which the OLT is connected", db_index = False];
- optional string switch_port = 18 [help_text = "Fabric port to which the OLT is connected", db_index = False];
- optional string outer_tpid = 19 [help_text = "Outer VLAN id field EtherType", db_index = False];
+ optional string switch_datapath_id = 17 [
+ help_text = "Fabric switch to which the OLT is connected",
+ db_index = False];
+ optional string switch_port = 18 [
+ help_text = "Fabric port to which the OLT is connected",
+ db_index = False];
+ optional string outer_tpid = 19 [
+ help_text = "Outer VLAN id field EtherType",
+ db_index = False];
- optional string nas_id = 20 [help_text = "Authentication ID (propagated to the free-radius server via sadis)", db_index = False];
+ optional string nas_id = 20 [
+ help_text = "Authentication ID (propagated to the free-radius server via sadis)",
+ db_index = False];
}
message PortBase (XOSBase){
option gui_hidden = True;
+ option description = "Base class for Port objects";
- required string name = 1 [help_text = "Human-readable name of port", db_index = True];
- required int32 port_no = 3 [help_text = "Port Number", db_index = False];
+ required string name = 1 [
+ help_text = "Human-readable name of port",
+ db_index = True];
+ required int32 port_no = 3 [
+ help_text = "Port Number",
+ db_index = False];
- optional string admin_state = 4 [help_text = "admin state, whether port should be enabled", db_index = False, feedback_state = True];
- optional string oper_status = 5 [help_text = "operational status, whether port is active", db_index = False, feedback_state = True];
+ optional string admin_state = 4 [
+ help_text = "admin state, whether port should be enabled",
+ db_index = False,
+ feedback_state = True];
+ optional string oper_status = 5 [
+ help_text = "operational status, whether port is active",
+ db_index = False,
+ feedback_state = True];
}
message PONPort (PortBase){
option verbose_name = "PON Port";
- option description="PON Port";
+ option description = "PON Port";
- required manytoone olt_device->OLTDevice:pon_ports = 1:1001 [help_text = "OLTDevice that owns this PONPort", db_index = True];
+ required manytoone olt_device->OLTDevice:pon_ports = 1:1001 [
+ help_text = "OLTDevice that owns this PONPort",
+ db_index = True];
}
message NNIPort (PortBase) {
option verbose_name = "NNI Port";
- required manytoone olt_device->OLTDevice:nni_ports = 1:1002 [help_text = "OLTDevice that owns this NNIPort", db_index = True];
+ option description = "NNI Port";
+
+ required manytoone olt_device->OLTDevice:nni_ports = 1:1002 [
+ help_text = "OLTDevice that owns this NNIPort",
+ db_index = True];
}
message ONUDevice (XOSBase){
option verbose_name = "ONU Device";
option description = "Represents a physical ONU device";
- required manytoone pon_port->PONPort:onu_devices = 1:1001 [help_text = "PONPort that connects this ONUDevice to an OLTDevice", db_index = True];
- required string serial_number = 2 [help_text = "Serial number of ONU Device", max_length = 254, db_index = False, tosca_key=True, unique = True];
- required string vendor = 3 [help_text = "Vendor of ONU Device", max_length = 254, db_index = False];
- required string device_type = 4 [help_text = "Device Type", default = "asfvolt16_olt", max_length = 254, db_index = False];
+ required manytoone pon_port->PONPort:onu_devices = 1:1001 [
+ help_text = "PONPort that connects this ONUDevice to an OLTDevice",
+ db_index = True];
+ required string serial_number = 2 [
+ help_text = "Serial number of ONU Device",
+ db_index = False,
+ max_length = 254,
+ tosca_key=True,
+ unique = True];
+ required string vendor = 3 [
+ help_text = "Vendor of ONU Device",
+ db_index = False,
+ max_length = 254];
+ required string device_type = 4 [
+ help_text = "Device Type",
+ db_index = False,
+ default = "asfvolt16_olt",
+ max_length = 254];
- optional string device_id = 5 [help_text = "Voltha Device ID", max_length = 254, db_index = False, feedback_state = True];
- optional string admin_state = 6 [help_text = "admin state, whether port should be enabled", choices = "(('DISABLED', 'DISABLED'), ('ENABLED', 'ENABLED'))", default="ENABLED", db_index = False];
- optional string oper_status = 7 [help_text = "oper_status", db_index = False, feedback_state = True];
- optional string connect_status = 8 [help_text = "operational status, whether port is active", db_index = False, feedback_state = True];
- optional string reason = 9 [help_text = "ONU device configuration state machine status message", db_index = False, feedback_state = True];
+ optional string device_id = 5 [
+ help_text = "Voltha Device ID",
+ db_index = False,
+ feedback_state = True,
+ max_length = 254];
+ optional string admin_state = 6 [
+ help_text = "admin state, whether port should be enabled",
+ choices = "(('DISABLED', 'DISABLED'), ('ENABLED', 'ENABLED'))",
+ db_index = False,
+ default = "ENABLED"];
+ optional string oper_status = 7 [
+ help_text = "oper_status",
+ db_index = False,
+ feedback_state = True];
+ optional string connect_status = 8 [
+ help_text = "operational status, whether port is active",
+ db_index = False,
+ feedback_state = True];
+ optional string reason = 9 [
+ help_text = "ONU device configuration state machine status message",
+ db_index = False,
+ feedback_state = True];
}
message PONONUPort (PortBase) {
option verbose_name = "ANI Port";
option description="Access Node Interface Port";
- required manytoone onu_device->ONUDevice:pononu_ports = 1:1001 [help_text = "ONUDevice that owns this PONONUPort", db_index = True];
+ required manytoone onu_device->ONUDevice:pononu_ports = 1:1001 [
+ help_text = "ONUDevice that owns this PONONUPort",
+ db_index = True];
}
message UNIPort (PortBase) {
option verbose_name = "UNI Port";
option description = "User Network Interface Port";
- required manytoone onu_device->ONUDevice:uni_ports = 1:1002 [help_text = "ONUDevice that owns this UNIPort", db_index = True];
+ required manytoone onu_device->ONUDevice:uni_ports = 1:1002 [
+ help_text = "ONUDevice that owns this UNIPort",
+ db_index = True];
}
message VOLTServiceInstance (ServiceInstance){
@@ -101,6 +231,11 @@
option verbose_name = "vOLT Service Instance";
option description = "Represents subscriber tenancy in the VOLT Service";
- optional string description = 1 [help_text = "Human-readable description", max_length = 254, db_index = False];
- optional manytoone onu_device->ONUDevice:volt_service_instances = 2:1003 [help_text = "ONUDevice that belongs to this Subscriber chain", db_index = True];
+ optional string description = 1 [
+ help_text = "Human-readable description",
+ db_index = False,
+ max_length = 254];
+ optional manytoone onu_device->ONUDevice:volt_service_instances = 2:1003 [
+ help_text = "ONUDevice that belongs to this Subscriber chain",
+ db_index = True];
}