commit | 747a7da76ceb4804e5c2e9136573d6f437ea6e0f | [log] [tgz] |
---|---|---|
author | Saurav Das <sauravdas@alumni.stanford.edu> | Thu Jun 27 12:28:06 2019 -0700 |
committer | Saurav Das <sauravdas@alumni.stanford.edu> | Fri Jun 28 23:02:55 2019 +0000 |
tree | 490087bb80ca673593fffa39f46072eb4ab08ca3 | |
parent | da04f24655353c76b106197d6028f1a614c783e4 [diff] |
Two fixes regarding meter handling First, while deleting an eapol flow, do not create a meter as a side-effect of a lookup failure. Second, do not remove bpInfo to Meter mapping when removing default eapol flow, as other ONUs are still using it and new ones can reuse it instead of creating duplicate meters. Change-Id: I6d62b24b4d4f6e27eba28c35bab7c5a2f5144aa9 (cherry picked from commit 80b6b6c21c5e2f87da07d10df3d5a8faf99990fe)