VOL-3787: Added alarm notification decode/AlarmMap support

Change-Id: I05e6188c279f26cd413e23ec068ff0993e7070c1
diff --git a/generated/twdmchannelphylodsperformancemonitoringhistorydata.go b/generated/twdmchannelphylodsperformancemonitoringhistorydata.go
index c8d3a2a..db46818 100644
--- a/generated/twdmchannelphylodsperformancemonitoringhistorydata.go
+++ b/generated/twdmchannelphylodsperformancemonitoringhistorydata.go
@@ -14,7 +14,7 @@
  * See the License for the specific language governing permissions and
  * limitations under the License.
  */
- /*
+/*
  * NOTE: This file was generated, manual edits will be overwritten!
  *
  * Generated by 'goCodeGenerator.py':
@@ -157,6 +157,20 @@
 		},
 		Access:  CreatedByOlt,
 		Support: UnknownSupport,
+		Alarms: AlarmMap{
+			1:  "BIP-32 bit error count",
+			2:  "PSBd HEC errors - corrected",
+			3:  "PSBd HEC errors - uncorrectable",
+			4:  "FS header errors - corrected",
+			5:  "FS header errors - uncorrectable",
+			6:  "Total LODS event count",
+			7:  "LODS - restored in operating TWDM channel",
+			8:  "LODS - restored in protection TWDM channel",
+			9:  "LODS - restored in discretionary TWDM channel",
+			10: "LODS - reactivations",
+			11: "LODS - handshake failure in protection channel",
+			12: "LODS - handshake failure in discretionary channel",
+		},
 	}
 }