VOL-4337: Code upgrade for 3/2020 G.988 support and remaining Extended Message Set support

Change-Id: I6c5e1a167216ad9b51e9da89460e9909465ae1bc
diff --git a/generated/epondownstreamperformancemonitoringconfiguration.go b/generated/epondownstreamperformancemonitoringconfiguration.go
new file mode 100644
index 0000000..8ee5afc
--- /dev/null
+++ b/generated/epondownstreamperformancemonitoringconfiguration.go
@@ -0,0 +1,116 @@
+/*
+ * Copyright (c) 2018 - present.  Boling Consulting Solutions (bcsw.net)
+ * Copyright 2020-present Open Networking Foundation
+
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+
+ * http://www.apache.org/licenses/LICENSE-2.0
+
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ *              https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// EponDownstreamPerformanceMonitoringConfigurationClassID is the 16-bit ID for the OMCI
+// Managed entity EPON downstream performance monitoring configuration
+const EponDownstreamPerformanceMonitoringConfigurationClassID = ClassID(406) // 0x0196
+
+var epondownstreamperformancemonitoringconfigurationBME *ManagedEntityDefinition
+
+// EponDownstreamPerformanceMonitoringConfiguration (Class ID: #406 / 0x0196)
+//	This ME represents window sizes and threshold values for EPON downstream PM operations which are
+//	defined in [IEEE 802.3] as: errored symbol period, errored frame, errored frame period and
+//	errored frame seconds summary.
+//
+//	The EPON ONU automatically instantiates an instance of this ME for each ANI-E.
+//
+//	Relationships
+//		An instance of this ME is associated with an ANI-E.
+//
+//	Attributes
+//		Managed Entity Id
+//			This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
+//			implicitly linked to an instance of the ANI-E. (R, set-by-create) (mandatory) (2-bytes)
+//
+//		Errored Symbol Period Window
+//			This attribute specifies the number of symbols in the measurement period, as defined in clause
+//			57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes)
+//
+//		Errored Symbol Period Threshold
+//			This attribute specifies the threshold of errored symbols for generating an event report, as
+//			defined in clause 57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes)
+//
+//		Errored Frame Window
+//			This attribute specifies the duration in units of 100-ms of the measurement period, as defined
+//			in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (2-bytes)
+//
+//		Errored Frame Threshold
+//			This attribute specifies the threshold of errored frames for generating an event report, as
+//			defined in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
+//
+//		Errored Frame Period Window
+//			This attribute specifies the duration in terms of frames of the measurement period, as defined
+//			in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
+//
+//		Errored Frame Period Threshold
+//			This attribute specifies the threshold of errored frames for generating an event report, as
+//			defined in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
+//
+//		Errored Frame Seconds Summary Window
+//			This attribute specifies the duration in units of 100ms of the measurement period, as defined in
+//			clause-57.5.3.4 of [IEEE-802.3]. (R, W) (optional) (2-bytes)
+//
+//		Errored Frame Seconds Summary Threshold
+//			This attribute specifies the threshold of errored frame seconds for generating an event report,
+//			as defined in clause 57.5.3.4 of [IEEE 802.3]. (R, W) (optional) (2-bytes)
+//
+type EponDownstreamPerformanceMonitoringConfiguration struct {
+	ManagedEntityDefinition
+	Attributes AttributeValueMap
+}
+
+func init() {
+	epondownstreamperformancemonitoringconfigurationBME = &ManagedEntityDefinition{
+		Name:    "EponDownstreamPerformanceMonitoringConfiguration",
+		ClassID: 406,
+		MessageTypes: mapset.NewSetWith(
+			Get,
+			Set,
+		),
+		AllowedAttributeMask: 0xff00,
+		AttributeDefinitions: AttributeDefinitionMap{
+			0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
+			1: Uint64Field("ErroredSymbolPeriodWindow", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, true, false, 1),
+			2: Uint64Field("ErroredSymbolPeriodThreshold", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, false, 2),
+			3: Uint16Field("ErroredFrameWindow", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, true, false, 3),
+			4: Uint32Field("ErroredFrameThreshold", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
+			5: Uint32Field("ErroredFramePeriodWindow", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, true, false, 5),
+			6: Uint32Field("ErroredFramePeriodThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6),
+			7: Uint16Field("ErroredFrameSecondsSummaryWindow", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7),
+			8: Uint16Field("ErroredFrameSecondsSummaryThreshold", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8),
+		},
+		Access:  CreatedByOnu,
+		Support: UnknownSupport,
+	}
+}
+
+// NewEponDownstreamPerformanceMonitoringConfiguration (class ID 406) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewEponDownstreamPerformanceMonitoringConfiguration(params ...ParamData) (*ManagedEntity, OmciErrors) {
+	return NewManagedEntity(*epondownstreamperformancemonitoringconfigurationBME, params...)
+}