// PhysicalPathTerminationPointPotsUniClassID is the 16-bit ID for the OMCI
// Managed entity Physical path termination point POTS UNI
-const PhysicalPathTerminationPointPotsUniClassID ClassID = ClassID(53)
+const PhysicalPathTerminationPointPotsUniClassID = ClassID(53) // 0x0035
var physicalpathterminationpointpotsuniBME *ManagedEntityDefinition
-// PhysicalPathTerminationPointPotsUni (class ID #53)
+// PhysicalPathTerminationPointPotsUni (Class ID: #53 / 0x0035)
// This ME represents a POTS UNI in the ONU, where a physical path terminates and physical path
// level functions (analogue telephony) are performed.
//
@@ -56,9 +56,9 @@
//
// Attributes
// Managed Entity Id
-// Managed entity ID: This attribute uniquely identifies each instance of this ME. This 2-byte
-// number indicates the physical position of the UNI. The first byte is the slot ID (defined in
-// clause 9.1.5). The second byte is the port ID, with the range 1..255. (R) (mandatory) (2-bytes)
+// This attribute uniquely identifies each instance of this ME. This 2-byte number indicates the
+// physical position of the UNI. The first byte is the slot ID (defined in clause 9.1.5). The
+// second byte is the port ID, with the range 1..255. (R) (mandatory) (2-bytes)
//
// Administrative State
// When the administrative state is set to lock, all user functions of this UNI are blocked, and
@@ -66,66 +66,85 @@
// default value for this attribute is outside the scope of this Recommendation. (R, W) (mandatory)
// (1 byte)
//
+// This attribute shuts down (2), locks (1) and unlocks (0) the functions performed by this ME. If
+// the administrative state is set to shut down while the POTS UNI line state is non-idle, no
+// action is taken until the POTS UNI line state changes to idle, whereupon the administrative
+// state changes to locked. If the administrative state is set to shut down and the POTS UNI line
+// state is already idle, the administrative state is immediately set to locked. In both cases, the
+// transition from shutting down to locked state is signalled with an AVC.
+//
// Deprecated
-// Deprecated: This attribute is not used and should not be supported. (R,-W) (optional) (2-bytes)
+// This attribute is not used and should not be supported. (R,-W) (optional) (2-bytes)
//
// Arc
-// ARC: See clause A.1.4.3. (R,-W) (optional) (1-byte)
+// See clause A.1.4.3. (R,-W) (optional) (1-byte)
//
// Arc Interval
-// ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte)
+// See clause A.1.4.3. (R,-W) (optional) (1-byte)
//
// Impedance
+// 2 C1=150 nF, R1=750 Ohm, R2=270 Ohm
+//
+// 3 C1=115 nF, R1=820 Ohm, R2=220 Ohm
+//
+// 4 C1=230 nF, R1=1050 Ohm, R2=320 Ohm
+//
// where C1, R1, and R2 are related as shown in Figure 9.9.1-1. Upon ME instantiation, the ONU sets
// this attribute to 0. (R,-W) (optional) (1-byte)
//
+// This attribute specifies the impedance for the POTS UNI. Valid values include the following.
+//
+// 0 600 Ohm
+//
+// 1 900 Ohm
+//
+// The following parameter sets from Annex C of [ETSI TS 101 270-1] are also defined:
+//
// Transmission Path
-// Transmission path: This attribute allows setting the POTS UNI either to full-time on-hook
-// transmission (0) or part-time on-hook transmission (1). Upon ME instantiation, the ONU sets this
-// attribute to 0. (R,-W) (optional) (1-byte)
+// This attribute allows setting the POTS UNI either to full-time on-hook transmission (0) or part-
+// time on-hook transmission (1). Upon ME instantiation, the ONU sets this attribute to 0. (R,-W)
+// (optional) (1-byte)
//
// Rx Gain
-// Rx gain: This attribute specifies a gain value for the received signal in the form of a 2s
-// complement number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the
-// affected signal is in the D to A direction, towards the telephone set. Upon ME instantiation,
-// the ONU sets this attribute to 0. (R, W) (optional) (1 byte)
+// This attribute specifies a gain value for the received signal in the form of a 2s complement
+// number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the affected signal is
+// in the D to A direction, towards the telephone set. Upon ME instantiation, the ONU sets this
+// attribute to 0. (R, W) (optional) (1 byte)
//
// Tx Gain
-// Tx gain: This attribute specifies a gain value for the transmit signal in the form of a 2s
-// complement number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the
-// affected signal is in the A to D direction, away from the telephone set. Upon ME instantiation,
-// the ONU sets this attribute to 0. (R, W) (optional) (1 byte)
+// This attribute specifies a gain value for the transmit signal in the form of a 2s complement
+// number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the affected signal is
+// in the A to D direction, away from the telephone set. Upon ME instantiation, the ONU sets this
+// attribute to 0. (R, W) (optional) (1 byte)
//
// Operational State
-// Operational state: This attribute indicates whether the ME is capable of performing its
-// function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte)
+// This attribute indicates whether the ME is capable of performing its function. Valid values are
+// enabled (0) and disabled (1). (R) (optional) (1-byte)
//
// Hook State
-// Hook state: This attribute indicates the current state of the subscriber line: 0-= on hook, 1-=
-// off hook (R) (optional) (1-byte)
+// This attribute indicates the current state of the subscriber line: 0-= on hook, 1-= off hook (R)
+// (optional) (1-byte)
//
// Pots Holdover Time
-// POTS holdover time: This attribute determines the time during which the POTS loop voltage is
-// held up when a LOS or softswitch connectivity is detected (please refer to the following table
-// for description of behaviours).. After the specified time elapses, the ONU drops the loop
-// voltage, and may thereby cause premises intrusion alarm or fire panel circuits to go active.
-// When the ONU ranges successfully on the PON or softswitch connectivity is restored, it restores
-// the POTS loop voltage immediately and resets the timer to zero. The attribute is expressed in
-// seconds. The default value 0 selects the vendor's factory policy. (R,-W) (optional) (2-bytes)
+// This attribute determines the time during which the POTS loop voltage is held up when a LOS or
+// softswitch connectivity is detected (please refer to the following table for description of
+// behaviours).. After the specified time elapses, the ONU drops the loop voltage, and may thereby
+// cause premises intrusion alarm or fire panel circuits to go active. When the ONU ranges
+// successfully on the PON or softswitch connectivity is restored, it restores the POTS loop
+// voltage immediately and resets the timer to zero. The attribute is expressed in seconds. The
+// default value 0 selects the vendor's factory policy. (R,-W) (optional) (2-bytes)
//
// Nominal Feed Voltage
-// Nominal feed voltage: This attribute indicates the designed nominal feed voltage of the POTS
-// loop. It is an absolute value with resolution 1-V. This attribute does not represent the actual
-// voltage measured on the loop, which is available through the test command. (R,-W) (optional)
-// (1-byte)
+// This attribute indicates the designed nominal feed voltage of the POTS loop. It is an absolute
+// value with resolution 1-V. This attribute does not represent the actual voltage measured on the
+// loop, which is available through the test command. (R,-W) (optional) (1-byte)
//
// Loss Of Softswitch
-// Loss of softswitch: This Boolean attribute controls whether the T/R holdover initiation
-// criteria. False disables loss of softswitch connectivity detection as criteria for initiating
-// the POTS holdover timer. True enables loss of softswitch connectivity detection as criteria for
-// initiating the POTS holdover timer. This attribute is optional (if not implemented, the POTS
-// holdover time is triggered on a LOS when POTS holdover is greater than zero). (R,-W) (optional)
-// (1-byte)
+// This Boolean attribute controls whether the T/R holdover initiation criteria. False disables
+// loss of softswitch connectivity detection as criteria for initiating the POTS holdover timer.
+// True enables loss of softswitch connectivity detection as criteria for initiating the POTS
+// holdover timer. This attribute is optional (if not implemented, the POTS holdover time is
+// triggered on a LOS when POTS holdover is greater than zero). (R,-W) (optional) (1-byte)
//
type PhysicalPathTerminationPointPotsUni struct {