Import of https://github.com/cboling/omci at commit 7495182a09db38a9b6454a4a457fdd111c1618ac

Change-Id: I3250449080300b21b9d81c64dcc33f98f2e4cd1b
diff --git a/generated/callcontrolperformancemonitoringhistorydata.go b/generated/callcontrolperformancemonitoringhistorydata.go
new file mode 100644
index 0000000..dfda0d7
--- /dev/null
+++ b/generated/callcontrolperformancemonitoringhistorydata.go
@@ -0,0 +1,114 @@
+/*
+ * Copyright (c) 2018 - present.  Boling Consulting Solutions (bcsw.net)
+ *
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+ * http://www.apache.org/licenses/LICENSE-2.0
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ *              https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// CallControlPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
+// Managed entity Call control performance monitoring history data
+const CallControlPerformanceMonitoringHistoryDataClassID ClassID = ClassID(140)
+
+var callcontrolperformancemonitoringhistorydataBME *ManagedEntityDefinition
+
+// CallControlPerformanceMonitoringHistoryData (class ID #140)
+//	This ME collects PM data related to the call control channel. Instances of this ME are created
+//	and deleted by the OLT.
+//
+//	For a complete discussion of generic PM architecture, refer to clause I.4.
+//
+//	Relationships
+//		An instance of this ME is associated with an instance of the PPTP POTS UNI ME.
+//
+//	Attributes
+//		Managed Entity Id
+//			Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an
+//			identical ID, this ME is implicitly linked to an instance of the PPTP POTS UNI. (R, setbycreate)
+//			(mandatory) (2-bytes)
+//
+//		Interval End Time
+//			Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
+//			(mandatory) (1-byte)
+//
+//		Threshold Data 1_2 Id
+//			Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
+//			contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
+//			data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
+//
+//		Call Setup Failures
+//			Call setup failures: This attribute counts call set-up failures. (R) (mandatory) (4-bytes)
+//
+//		Call Setup Timer
+//			Call setup timer: This attribute is a high water-mark that records the longest duration of a
+//			single call set-up detected during this interval. Time is measured in milliseconds from the time
+//			an initial set-up was requested by the subscriber until the time at which a response was
+//			provided to the subscriber in the form of busy tone, audible ring tone, etc. (R) (mandatory)
+//			(4-bytes)
+//
+//		Call Terminate Failures
+//			Call terminate failures: This attribute counts the number of calls that were terminated with
+//			cause. (R) (mandatory) (4-bytes)
+//
+//		Analog Port Releases
+//			Analog port releases: This attribute counts the number of analogue port releases without
+//			dialling detected (abandoned calls). (R) (mandatory) (4-bytes)
+//
+//		Analog Port Off_Hook Timer
+//			Analog port off-hook timer: This attribute is a high water-mark that records the longest period
+//			of a single off-hook detected on the analogue port. Time is measured in milliseconds. (R)
+//			(mandatory) (4-bytes)
+//
+type CallControlPerformanceMonitoringHistoryData struct {
+	ManagedEntityDefinition
+	Attributes AttributeValueMap
+}
+
+func init() {
+	callcontrolperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
+		Name:    "CallControlPerformanceMonitoringHistoryData",
+		ClassID: 140,
+		MessageTypes: mapset.NewSetWith(
+			Create,
+			Delete,
+			Get,
+			Set,
+		),
+		AllowedAttributeMask: 0xfe00,
+		AttributeDefinitions: AttributeDefinitionMap{
+			0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
+			1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
+			2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
+			3: Uint32Field("CallSetupFailures", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
+			4: Uint32Field("CallSetupTimer", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
+			5: Uint32Field("CallTerminateFailures", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
+			6: Uint32Field("AnalogPortReleases", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
+			7: Uint32Field("AnalogPortOffHookTimer", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
+		},
+		Access:  CreatedByOlt,
+		Support: UnknownSupport,
+	}
+}
+
+// NewCallControlPerformanceMonitoringHistoryData (class ID 140) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewCallControlPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {