Import of https://github.com/cboling/omci at commit 7495182a09db38a9b6454a4a457fdd111c1618ac
Change-Id: I3250449080300b21b9d81c64dcc33f98f2e4cd1b
diff --git a/generated/xdsllineconfigurationprofilepart3.go b/generated/xdsllineconfigurationprofilepart3.go
new file mode 100644
index 0000000..54dff5e
--- /dev/null
+++ b/generated/xdsllineconfigurationprofilepart3.go
@@ -0,0 +1,197 @@
+/*
+ * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
+ *
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+ * http://www.apache.org/licenses/LICENSE-2.0
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ * https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// XdslLineConfigurationProfilePart3ClassID is the 16-bit ID for the OMCI
+// Managed entity xDSL line configuration profile part 3
+const XdslLineConfigurationProfilePart3ClassID ClassID = ClassID(106)
+
+var xdsllineconfigurationprofilepart3BME *ManagedEntityDefinition
+
+// XdslLineConfigurationProfilePart3 (class ID #106)
+// The overall xDSL line configuration profile is modelled in several parts, all of which are
+// associated together through a common ME ID (the client PPTP xDSL UNI part 1 has a single
+// pointer, which refers to the entire set of line configuration profile parts).
+//
+// Relationships
+// An instance of this ME may be associated with zero or more instances of an xDSL UNI.
+//
+// Attributes
+// Managed Entity Id
+// Managed entity ID: This attribute uniquely identifies each instance of this ME. All xDSL and
+// VDSL2 line configuration profiles and extensions that pertain to a given PPTP xDSL UNI must
+// share a common ME ID. (R, setbycreate) (mandatory) (2-bytes)
+//
+// Loop Diagnostics Mode Forced Ldsf
+// Only while the line power management state is L3 can the line be forced into loop diagnostic
+// mode. When loop diagnostic procedures complete successfully, the ONU resets this attribute to 0.
+// The line remains in the L3 idle state. The loop diagnostics data are available at least until
+// the line is forced to the L0 state. As long as loop diagnostic procedures have not completed
+// successfully, attempts are made to do so, until the loop diagnostic mode is no longer forced on
+// the line through this configuration parameter. If loop diagnostic procedures cannot be completed
+// successfully after a vendordiscretionary number of retries or within a vendor-discretionary
+// timeout, then an initialization failure occurs. (R,-W, setbycreate) (mandatory) (1-byte)
+//
+// Automode Cold Start Forced
+// Automode is defined as the case where multiple operation modes are enabled in xTSE (Table
+// 9.7.12-1) and where the selection of the operation mode to be used for transmission depends, not
+// only on the common capabilities of both xTUs (as exchanged in [ITU-T G.994.1]), but also on
+// achievable data rates under given loop conditions. (R,-W, setbycreate) (mandatory if automode is
+// supported) (1-byte)
+//
+// L2 Atpr
+// L2ATPR: This parameter specifies the maximum aggregate transmit power reduction that can be
+// performed in the L2 request (i.e., at the transition of L0 to L2 state) or through a single
+// power trim in the L2 state. It is only valid for [ITUT-G.992.3], [ITUT-G.992.4] and
+// [ITUT-G.992.5]. This attribute ranges from 0 (0-dB) dB to 31 (31-dB). (R, W, setbycreate)
+// (mandatory) (1 byte)
+//
+// L2 Atprt
+// L2ATPRT: This parameter specifies the total maximum aggregate transmit power reduction (in
+// decibels) that can be performed in an L2 state. This is the sum of all reductions of L2 requests
+// (i.e., at transitions from L0 to L2 state) and power trims. This attribute ranges from 0 (0 dB)
+// dB to 31 (31 dB). (R, W, setbycreate) (mandatory) (1 byte)
+//
+// Force Inp Downstream
+// Force INP downstream: When set to 1, the FORCEINPds attribute forces the framer settings of all
+// downstream bearer channels to be selected such that the impulse noise protection (INP) computed
+// according to the formula specified in the relevant Recommendation is greater than or equal to
+// the minimal INP requirement. The default value 0 disables this function. (R, W) (mandatory for
+// [ITU-T G.993.2], optional for other Recommendations that support it) (1 byte)
+//
+// Force Inp Upstream
+// Force INP upstream: When set to 1, the FORCEINPus attribute forces the framer settings of all
+// upstream bearer channels to be selected such that the INP computed according to the formula
+// specified in the relevant Recommendation is greater than or equal to the minimal INP
+// requirement. The default value 0 disables this function. (R, W) (mandatory for [ITU-T G.993.2],
+// optional for other Recommendations that support it) (1 byte)
+//
+// Update Request Flag For Near_End Test Parameters
+// Update request flag for near-end test parameters: The UPDATE-TEST-NE attribute forces an update
+// of all near-end test parameters that can be updated during showtime in [ITU-T G.993.2]. Update
+// is triggered by setting this attribute to 1, whereupon the near-end test parameters are expected
+// to be updated within 10-s, and the ONU should reset the attribute value to 0. The update request
+// flag is independent of any autonomous update process in the system. The update request attribute
+// must be prepared to accept another set after a period not to exceed 3-min, a period that starts
+// when the flag is set via the OMCI or by an autonomous process in the system. (R,-W) (optional)
+// (1-byte)
+//
+// Update Request Flag For Far_End Test Parameters
+// Update request flag for far-end test parameters: The UPDATE-TEST-FE attribute forces an update
+// of all far-end test parameters that can be updated during showtime in [ITU-T G.993.2]. Update is
+// triggered by setting this attribute to 1, whereupon the far-end test parameters are expected to
+// be updated within 10-s, and the ONU should reset the attribute value to 0. The update request
+// flag is independent of any autonomous update process in the system. The update request attribute
+// must be prepared to accept another set after a period not to exceed 3-min, a period that starts
+// when the flag is set via the OMCI or by an autonomous process in the system. (R,-W) (optional)
+// (1-byte)
+//
+// Inm Inter Arrival Time Offset Upstream
+// INM inter-arrival time offset upstream: INMIATOus is the inter-arrival time (IAT) offset that
+// the xTU-C receiver uses to determine in which bin of the IAT histogram the IAT is reported.
+// Valid values for INMIATO range from 3 to 511 discrete multi-tone (DMT) symbols in steps of 1 DMT
+// symbol. (R,-W) (optional) (2-bytes)
+//
+// Inm Inter_Arrival Time Step Upstream
+// INM inter-arrival time step upstream: INMIATSus is the IAT step that the xTU-C receiver uses to
+// determine in which bin of the IAT histogram the IAT is reported. Valid values for INMIATS range
+// from 0 to 7 in steps of 1. (R,-W) (optional) (1-byte)
+//
+// Inm Cluster Continuation Value Upstream
+// INM cluster continuation value upstream: INMCCus is the cluster continuation value that the
+// xTU-C receiver uses in the cluster indication process described in the applicable
+// Recommendation. Valid values for INMCC range from 0 to 64 DMT symbols in steps of 1 DMT symbol.
+// (R,-W) (optional) (1-byte)
+//
+// Inm Equivalent Inp Mode Upstream
+// INM equivalent INP mode upstream: INM_INPEQ_MODEus is the INM equivalent INP mode that the xTU-C
+// receiver uses in the computation of the equivalent INP, as defined in the applicable
+// Recommendation. Valid values for INM_INPEQ_MODE are 0..4. (R,-W) (optional) (1-byte)
+//
+// Inm Inter Arrival Time Offset Downstream
+// INM inter-arrival time offset downstream: INMIATOds is the IAT offset that the xTU-R receiver
+// uses to determine in which bin of the IAT histogram the IAT is reported. Valid values for
+// INMIATO range from 3 to 511 DMT symbols in steps of 1 DMT symbol. (R,-W) (optional) (2-bytes)
+//
+// Inm Inter_Arrival Time Step Downstream
+// INM inter-arrival time step downstream: INMIATSds is the IAT step that the xTU-R receiver uses
+// to determine in which bin of the IAT histogram the IAT is reported. Valid values for INMIATS
+// range from 0 to 7 in steps of 1. (R,-W) (optional) (1-byte)
+//
+// Inm Cluster Continuation Value Downstream
+// INM cluster continuation value downstream: INMCCds is the cluster continuation value that the
+// xTU-R receiver uses in the cluster indication process described in the applicable
+// Recommendation. Valid values for INMCC range from 0 to 64 DMT symbols in steps of 1 DMT symbol.
+// (R,-W) (optional) (1-byte)
+//
+// Inm Equivalent Inp Mode Downstream
+// INM equivalent INP mode downstream: INM_INPEQ_MODEds is the INM equivalent INP mode that the
+// xTU-R receiver uses in the computation of the equivalent INP, as defined in the applicable
+// Recommendation. Valid values for INM_INPEQ_MODE are 0..4. (R,-W) (optional) (1-byte)
+//
+type XdslLineConfigurationProfilePart3 struct {
+ ManagedEntityDefinition
+ Attributes AttributeValueMap
+}
+
+func init() {
+ xdsllineconfigurationprofilepart3BME = &ManagedEntityDefinition{
+ Name: "XdslLineConfigurationProfilePart3",
+ ClassID: 106,
+ MessageTypes: mapset.NewSetWith(
+ Create,
+ Delete,
+ Get,
+ Set,
+ ),
+ AllowedAttributeMask: 0xffff,
+ AttributeDefinitions: AttributeDefinitionMap{
+ 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
+ 1: ByteField("LoopDiagnosticsModeForcedLdsf", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1),
+ 2: ByteField("AutomodeColdStartForced", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
+ 3: ByteField("L2Atpr", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3),
+ 4: ByteField("L2Atprt", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 4),
+ 5: ByteField("ForceInpDownstream", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5),
+ 6: ByteField("ForceInpUpstream", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, false, false, 6),
+ 7: ByteField("UpdateRequestFlagForNearEndTestParameters", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), true, true, false, 7),
+ 8: ByteField("UpdateRequestFlagForFarEndTestParameters", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), true, true, false, 8),
+ 9: Uint16Field("InmInterArrivalTimeOffsetUpstream", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, true, false, 9),
+ 10: ByteField("InmInterArrivalTimeStepUpstream", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), false, true, false, 10),
+ 11: ByteField("InmClusterContinuationValueUpstream", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, true, false, 11),
+ 12: ByteField("InmEquivalentInpModeUpstream", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, true, false, 12),
+ 13: Uint16Field("InmInterArrivalTimeOffsetDownstream", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, Write), false, true, false, 13),
+ 14: ByteField("InmInterArrivalTimeStepDownstream", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read, Write), false, true, false, 14),
+ 15: ByteField("InmClusterContinuationValueDownstream", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read, Write), false, true, false, 15),
+ 16: ByteField("InmEquivalentInpModeDownstream", UnsignedIntegerAttributeType, 0x0001, 0, mapset.NewSetWith(Read, Write), false, true, false, 16),
+ },
+ Access: CreatedByOlt,
+ Support: UnknownSupport,
+ }
+}
+
+// NewXdslLineConfigurationProfilePart3 (class ID 106) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewXdslLineConfigurationProfilePart3(params ...ParamData) (*ManagedEntity, OmciErrors) {
+ return NewManagedEntity(*xdsllineconfigurationprofilepart3BME, params...)
+}