blob: 172ab1a76005ec88ddafa35cf1280509b071999b [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
David K. Bainbridgeadf422d2021-04-09 16:06:41 +000017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// XdslChannelDownstreamStatusDataClassID is the 16-bit ID for the OMCI
29// Managed entity xDSL channel downstream status data
Chip Boling610117d2021-09-09 11:24:34 -050030const XdslChannelDownstreamStatusDataClassID = ClassID(102) // 0x0066
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var xdslchanneldownstreamstatusdataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// XdslChannelDownstreamStatusData (Class ID: #102 / 0x0066)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME contains downstream channel status data for an xDSL UNI. The ONU automatically creates
36// or deletes instances of this ME upon the creation or deletion of a PPTP xDSL UNI part 1.
37//
38// NOTE - [ITU-T G.997.1] specifies that bit rate attributes have a granularity of 1000-bit/s. If
39// ITU-T G.997.1 compliance is required, the ONU should only report values with this granularity.
40//
41// Relationships
42// One or more instances of this ME are associated with an instance of an xDSL UNI.
43//
44// Attributes
45// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050046// This attribute uniquely identifies each instance of this ME. The two MSBs of the first byte are
47// the bearer channel ID. Excluding the first 2-bits of the first byte, the remaining part of the
48// ME ID is identical to that of this ME's parent PPTP xDSL UNI part 1. (R) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060049//
50// Actual Interleaving Delay
Chip Boling610117d2021-09-09 11:24:34 -050051// This attribute is the actual one-way interleaving delay introduced by the PMS-TC between the
52// alpha and beta reference points, excluding delay in the L1 and L2 states. In the L1 and L2
53// states, the attribute contains the interleaving delay in the previous L0 state. For ADSL, this
54// attribute is derived from the S and D attributes as cap(S*D)/4 ms, where S is the number of
55// symbols per codeword, D is the interleaving depth and cap() denotes rounding to the next higher
56// integer. For [ITU-T G.993.2], this attribute is computed according to the formula in clause 9.7
57// of [ITUT-G.993.2]. The actual interleaving delay is coded in milliseconds, rounded to the
58// nearest millisecond. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060059//
60// Actual Data Rate
Chip Boling610117d2021-09-09 11:24:34 -050061// This parameter reports the actual net data rate of the bearer channel, excluding the rate in the
62// L1 and L2 states. In the L1 or L2 state, the parameter contains the net data rate in the
63// previous L0 state. The data rate is coded in bits per second. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060064//
65// Previous Data Rate
Chip Boling610117d2021-09-09 11:24:34 -050066// This parameter reports the previous net data rate of the bearer channel just before the latest
67// rate change event occurred, excluding transitions between the L0 state and the L1 or L2 states.
68// A rate change can occur at a power management state transition, e.g., at full or short
69// initialization, fast retrain or power down, or at a dynamic rate adaptation. The rate is coded
70// in bits per second (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060071//
72// Actual Impulse Noise Protection
Chip Boling610117d2021-09-09 11:24:34 -050073// The ACTINP attribute reports the actual INP on the bearer channel in the L0 state. In the L1 or
74// L2 state, the attribute contains the INP in the previous L0 state. The value of this attribute
75// is a number of DMT symbols, with a granularity of 0.1 symbols. Its range is from 0 (0.0 symbols)
76// to 254 (25.4 symbols). The special value 255 indicates an ACTINP higher than 25.4. (R) (optional
77// for [ITU-T G.992.1], mandatory for other xDSL Recommendations that support this attribute)
78// (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060079//
80// Actual Size Of Reed_Solomon Codeword
81// Actual size of Reed-Solomon codeword: The NFEC attribute reports the actual Reed-Solomon
82// codeword size used in the latency path in which the bearer channel is transported. The value is
83// coded in bytes, and ranges from 0..255. (R) (mandatory for ITUT-G.993.2 VDSL2, optional for
84// others) (1-byte)
85//
86// Actual Number Of Reed_Solomon Redundancy Bytes
87// Actual number of Reed-Solomon redundancy bytes: The RFEC attribute reports the actual number of
88// Reed-Solomon redundancy bytes per codeword used in the latency path in which the bearer channel
89// is transported. The value is coded in bytes, and ranges from 0..16. The value 0 indicates no
90// Reed-Solomon coding. (R) (mandatory for ITUT-G.993.2 VDSL2, optional for others) (1-byte)
91//
92// Actual Number Of Bits Per Symbol
Chip Boling610117d2021-09-09 11:24:34 -050093// The LSYMB attribute reports the actual number of bits per symbol assigned to the latency path in
94// which the bearer channel is transported, excluding trellis overhead. The value is coded in bits,
95// and ranges from 0..65535. (R) (mandatory for [TU-T G.993.2 VDSL2, optional for others) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060096//
97// Actual Interleaving Depth
Chip Boling610117d2021-09-09 11:24:34 -050098// The INTLVDEPTH attribute reports the actual depth of the interleaver used in the latency path in
99// which the bearer channel is transported. The value ranges from 1..4096 in steps of 1. The value
100// 1 indicates no interleaving. (R) (mandatory for ITU-T G.993.2 VDSL2, optional for others)
101// (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -0600102//
103// Actual Interleaving Block Length
Chip Boling610117d2021-09-09 11:24:34 -0500104// The INTLVBLOCK attribute reports the actual block length of the interleaver used in the latency
105// path in which the bearer channel is transported. The value ranges from 4..255 in steps of 1. (R)
106// (mandatory for ITU-T G.993.2 VDSL2, undefined for others) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -0600107//
108// Actual Latency Path
Chip Boling610117d2021-09-09 11:24:34 -0500109// The LPATH attribute reports the index of the actual latency path in which the bearer channel is
110// transported. Valid values are 0..3. In [ITUT-G.992.1], the fast path is mapped to latency index
111// 0; the interleaved path to index 1. (R) (mandatory for ITU-T G.993.2 VDSL2, optional for others)
112// (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -0600113//
Chip Boling610117d2021-09-09 11:24:34 -0500114// Actual Impulse Noise Protection Against Repetitive Electrical Impulse Noise Actinp_Rein
Chip Boling6e27b352020-02-14 09:10:01 -0600115// Actual impulse noise protection against repetitive electrical impulse noise (ACTINP_REIN): If
116// retransmission is used in a given transmit direction, this parameter reports the actual INP
117// against REIN on the bearer channel. The INP of this attribute is equal to the integer value
118// multiplied by 0.1 symbols. Valid values and usage are given in clause 7.5.2.9 of [ITU-T G.997.1]
119// (R) (optional) (1-byte)
120//
121type XdslChannelDownstreamStatusData struct {
122 ManagedEntityDefinition
123 Attributes AttributeValueMap
124}
125
126func init() {
127 xdslchanneldownstreamstatusdataBME = &ManagedEntityDefinition{
128 Name: "XdslChannelDownstreamStatusData",
129 ClassID: 102,
130 MessageTypes: mapset.NewSetWith(
131 Get,
132 ),
133 AllowedAttributeMask: 0xffe0,
134 AttributeDefinitions: AttributeDefinitionMap{
135 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
136 1: ByteField("ActualInterleavingDelay", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
137 2: Uint32Field("ActualDataRate", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), false, false, false, 2),
138 3: Uint32Field("PreviousDataRate", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
139 4: ByteField("ActualImpulseNoiseProtection", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
140 5: ByteField("ActualSizeOfReedSolomonCodeword", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
141 6: ByteField("ActualNumberOfReedSolomonRedundancyBytes", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
142 7: Uint16Field("ActualNumberOfBitsPerSymbol", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
143 8: Uint16Field("ActualInterleavingDepth", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
144 9: ByteField("ActualInterleavingBlockLength", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
145 10: ByteField("ActualLatencyPath", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10),
Chip Boling610117d2021-09-09 11:24:34 -0500146 11: ByteField("ActualImpulseNoiseProtectionAgainstRepetitiveElectricalImpulseNoiseActinpRein", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11),
Chip Boling6e27b352020-02-14 09:10:01 -0600147 },
148 Access: CreatedByOnu,
149 Support: UnknownSupport,
150 }
151}
152
153// NewXdslChannelDownstreamStatusData (class ID 102) creates the basic
154// Managed Entity definition that is used to validate an ME of this type that
155// is received from or transmitted to the OMCC.
156func NewXdslChannelDownstreamStatusData(params ...ParamData) (*ManagedEntity, OmciErrors) {
157 return NewManagedEntity(*xdslchanneldownstreamstatusdataBME, params...)