- 2fb8147 VOL-3722 Processing onu related indications in occurence order by Mahir Gunyel · 4 years ago
- df392e1 VOL-3718 Packets coming from Open OLT Adapter to the VOLTHA Core always have zero in their UNI port field. OLT Adapter should set the true UNI port info to the control packets before passing them to the VOLTHA Core in the scope of packet-in workflow. by Esin Karaman · 4 years ago
- 49a5d56 VOL-3646 Fix for removal of DELETED admin state by Himani Chawla · 4 years ago
- 4aff186 [VOL-3644] fixed wrong topic names by serkant.uluderya · 4 years, 2 months ago
- dfa7a97 [VOL-3624] Parametrizing the KV-Store path by Matteo Scandolo · 4 years ago
- eb45029 Update log level of packet-in be at DebugLevel. by Girish Gowdra · 4 years, 1 month ago
- fb3d610 VOL-3521 : scale: intermittent issue - voltha complains that different meter is in use for subscriber by Girish Gowdra · 4 years, 1 month ago v3.0.1
- b1caa44 VOL-3557: OLT delete is causing the openolt adapter to panic sometimes by Girish Gowdra · 4 years, 1 month ago
- e8f473b - Add missing RWLock protection around accessing subscriberDataPathFlowIDMap. by Girish Gowdra · 4 years, 1 month ago
- a09aeab VOL-3419: OpenOLT adapter at scale constantly takes more that 10 seconds to react to flows by Girish Gowdra · 4 years, 2 months ago v3.0.0
- 2f6b5bc Adding onu and uni information to SedulerQueues errors by Matteo Scandolo · 4 years, 2 months ago
- 9602eb4 VOL-3419: OpenOLT adapter at scale constantly takes more that 10 seconds to react to flows by Girish Gowdra · 4 years, 2 months ago
- bfe0843 [VOL-3481] Returning error upon faliures in the divideAndAddFlow method by Andrea Campanella · 4 years, 2 months ago
- 7cf3a05 VOL-3444 Handling of ONT Activation Failure and generation of an alarm by kesavand · 4 years, 3 months ago
- 494c208 VOL-3395 Encryption of the OMCC GEM by kesavand · 4 years, 3 months ago v2.5.4
- 935f7af [VOL-3199] Added support for dynamic enable/disable of Trace Publishing by Girish Kumar · 4 years, 3 months ago v2.5.3
- 1183b4d Initialize the flowMgr.perGemPortLock MapMutex before invoking loadFlowIDlistForGem by Girish Gowdra · 4 years, 3 months ago
- 3af43e1 [VOL-3228] device-id logging consistancy by divyadesai · 4 years, 3 months ago
- a1ea2aa [VOL-3424] Switch completely to Context based Logger instance by Girish Kumar · 4 years, 3 months ago
- 738c52a Adding lock on flowsUsedByGemPort map Adding lock on OnuDevice.uniPorts map by Matteo Scandolo · 4 years, 3 months ago
- 8f4e432 [VOL-3141] Enhance Context with OpenTracing Span by Neha Sharma · 4 years, 3 months ago
- 0f6f8d0 Sending VLAN informations together with the DHCP flow by Matteo Scandolo · 4 years, 3 months ago v2.5.2
- 93e9174 [VOL-3196] Enhanced gRPC interfaces to create and propagate Span for log correlation by Girish Kumar · 4 years, 4 months ago
- cc0dce6 [VOL-3375]Remove field pkg from log statements by Rohan Agrawal · 4 years, 4 months ago
- e6ff101 VOL-3344 - Enabled default linters and fixed found issues. by Kent Hagerman · 4 years, 4 months ago
- 7fb80c2 VOL-3347 GEM ports kept for packet-outs should be in pon-onu-uni-vlan-pbit basis instead of per pon-onu-uni basis. by Esin Karaman · 4 years, 4 months ago
- d519bbf VOL-3112 Group removal support by Open OLT Adapter by Esin Karaman · 4 years, 5 months ago
- f1db18b VOL-3121 - Removing usage of device.Ports by Kent Hagerman · 4 years, 4 months ago
- 502056b VOL-3340: ONU events should contain both OLT and ONU device ID by Amit Ghosh · 4 years, 4 months ago
- abf9c51 [VOL-3269] Using a global lock on onuGemInfoLock by Matteo Scandolo · 4 years, 5 months ago
- 96b7bf2 [VOL-3069]Pass Context in methods which are performing logging and need the context by Neha Sharma · 4 years, 5 months ago
- 748de5c VOL-3314: ONU discovered entry is not cleared in OLT adapter on ONU by Girish Gowdra · 4 years, 5 months ago
- 2ba0e0b [VOL-1348] EPON tech profile support by Takahiro Suzuki · 4 years, 5 months ago
- 9218624 improving logs by Matteo Scandolo · 4 years, 5 months ago
- 631ef3d VOL-3202: Include port capability in the port create message. by Girish Gowdra · 4 years, 5 months ago
- da5e0b2 [VOL-3085]Implement UpdatePmConfig api for voltha-openolt-adapter by Rohan Agrawal · 4 years, 6 months ago
- 2c0d274 [VOL-3193] Moving OpenoltFlowManager lock on a per pon base by Matteo Scandolo · 4 years, 5 months ago
- 3f221ae [VOL-2736]:host and port should be specified as a single argument not as two separate arguments by Neha Sharma · 4 years, 7 months ago v2.4.8
- 95a3fcf VOL-3023 - enable stop indication while in backoff by David Bainbridge · 4 years, 5 months ago
- 89ae6d8 VOL-3155: Synchronize flow-removal and ONU delete handling by Girish Gowdra · 4 years, 6 months ago
- a1efa64 VOL-2324 Alarm - ONU Itu Pon Stats by Devmalya Paul · 4 years, 7 months ago v2.4.7
- c0878ec [VOL-2952] :changes to fill port labels for PON ports with easily understandable values by Chaitrashree G S · 4 years, 6 months ago
- 75f0e29 VOL-3095: Added olt device_id in ONU Discovery Event by Amit Ghosh · 4 years, 6 months ago
- 8c9b4f6 Lowering frequent and long log by Andrea Campanella · 4 years, 6 months ago
- 2691297 [VOL-2930] Changed log behaviour for openolt adapter by Shrey Baid · 4 years, 7 months ago v2.4.6
- 34815db VOL-3065: Concurrent metrics context map access causing panic by Girish Gowdra · 4 years, 6 months ago
- 429f950 VOL-2973: ONT Reboot is not bringing ONU back to 'omci-flows-pushed' state by Girish Gowdra · 4 years, 6 months ago
- c43a66e [VOL-3068] Openolt flow manager must support set_field action for vlan_pcp by Gamze Abaka · 4 years, 6 months ago
- 985938d VOL-2967: Remove redundant variables from DeviceHandler struct by Thomas Lee S · 4 years, 7 months ago
- aaf9c10 VOL-2948: Added PON and NNI information to metrics by Kishore Darapu · 4 years, 6 months ago v2.4.5
- 807a2a0 [VOL-2889] adding devicehandler logs addtl. features by Shrey Baid · 4 years, 7 months ago v2.4.4
- eb5294e VOL-897 Onu Differential Reach Exceeded Alarm by Devmalya Paul · 4 years, 8 months ago v2.4.3
- 78a1d2a [VOL-2975] Changes to OpenOLT adapter for supporting multi-tcont by Gamze Abaka · 4 years, 7 months ago
- 3262521 [VOL-2990] - Fix missing type assertion for IgmpProto classifier by Girish Gowdra · 4 years, 7 months ago
- 9931ad6 [VOL-936] Missing mocks and comments. Lowering log level for chatty messages by Andrea Campanella · 4 years, 7 months ago
- db587af [VOL-936] Add changes for onu distance from olt by Dinesh Belwalkar · 4 years, 9 months ago
- 724d085 [VOL-2774] Allow not filtering the pbit values for the TT workflow by Gamze Abaka · 4 years, 8 months ago
- d625b4c [VOL-2890] Using olt-device-id in the path of a tech-profile by Matteo Scandolo · 4 years, 8 months ago v2.4.2
- 0f89fd2 VOL-2916 Use cached values instead of childDevice query by Mahir Gunyel · 4 years, 7 months ago
- 85f3731 VOL-2880: Reduction of Unit Test Time by Thomas Lee S · 4 years, 8 months ago
- b77ded9 [VOL-2895] : Pings fail intermittently after OLT reboot and ONU disable by Girish Gowdra · 4 years, 7 months ago v2.4.0
- c4b1911 Avoid crash when trying to log nil group.Desc by Jonathan Hart · 4 years, 8 months ago
- 38d533d [VOL-2848] : Protect concurrent access for PON resources by Girish Gowdra · 4 years, 8 months ago
- 24f83e2 VOL-2776 Start_omci_test is unimplemented for OLT by Scott Baker · 4 years, 8 months ago
- 668ea5f [VOL-2643] Removing unused UpdateOnuGemInfo by Andrea Campanella · 4 years, 8 months ago
- ceea2e0 VOL-2841: Remove old backward compatible omci message checking code by Matt Jeanneret · 4 years, 8 months ago
- 868131c [VOL-2845]: Fix concurrent access of SouthBoundPort data in statsmanager module by Girish Gowdra · 4 years, 8 months ago
- b83b39d [VOL-2638] Returning error when storing data for new ONU by Andrea Campanella · 4 years, 8 months ago
- 3ab6d21 [VOL-2801] : Following OLT reboot, the readIndication receive stream would have by Girish Gowdra · 4 years, 8 months ago
- 3f97491 [VOL-2801] : readIndication routine going in an infinite loop on delete device. by Girish Gowdra · 4 years, 8 months ago
- 2ad402b [VOL-2694] Use package specific logger instance in all log statements by Girish Kumar · 4 years, 8 months ago
- d26f6b1 [VOL-2782] Update go.mod of voltha-go,open-olt-adapter,ofagent-go and voltctl to be compatible with latest version of voltha-lig-go by divyadesai · 4 years, 8 months ago
- 65409d8 VOL-2775 Multicast flows can not be installed due to the following error. by Esin Karaman · 4 years, 8 months ago
- cefae19 [VOL-2786] : Handle flow deletes completely before proceeding onto by Girish Gowdra · 4 years, 8 months ago
- a464925 [VOL-2741]: code changes to support OLT reboot by Chaitrashree G S · 4 years, 8 months ago
- 2440047 VOL-2747 Alarms should log at DEBUG level by Devmalya Paul · 4 years, 8 months ago v2.3.19
- 34a0028 VOL-812: If fiber is pulled at ONU side, ONU LOS alarm will not get clear from kafka bus. by Thiyagarajan Subramani · 4 years, 8 months ago v2.3.18
- f26e488 [VOL-2612] Remove error log when returning error from methods by Girish Kumar · 4 years, 9 months ago v2.3.17
- 41a762d VOL-883 Onu Loss of Acknowledgement Alarm by Devmalya Paul · 4 years, 9 months ago v2.3.16
- c63bba9 [VOL-2641] Returning errors for flows and groups from the open olt adapter to the core by Andrea Campanella · 4 years, 8 months ago v2.3.15
- bcdb144 VOL-2691 ONU Discovery event not raised by Devmalya Paul · 4 years, 9 months ago
- fcddfcf VOL-2459 Move to matching on multicast-IP address after moving to BAL 3.2.3.2 by Esin Karaman · 4 years, 9 months ago v2.3.13
- e420b5f [VOL-2644]:handle failed scenarios while cleaning up pon resources by Chaitrashree G S · 4 years, 9 months ago v2.3.12
- 94109f1 VOL-2639: Creation of common errors package by Thomas Lee S · 4 years, 9 months ago
- 7acc0b9 [VOL-2517] Using VLAN ANY (4096) to check for tagged ONU traffic instead of valid 4095 by Andrea Campanella · 4 years, 9 months ago v2.3.11
- 6f063a6 Alarm - ONU Remote Defect Indicator by Devmalya Paul · 4 years, 9 months ago v2.3.10
- dbd960e VOL-2640 Restructure openolt-adapter repo to best practices by Scott Baker · 4 years, 9 months ago