VOL-4208 - Free allocated Tcont if failed in device
Change-Id: I4c59efc1de4fad2e4d51727f862b3ec0229bdce7
diff --git a/internal/pkg/onuadaptercore/omci_ani_config.go b/internal/pkg/onuadaptercore/omci_ani_config.go
index e50bd58..9cb7e4c 100644
--- a/internal/pkg/onuadaptercore/omci_ani_config.go
+++ b/internal/pkg/onuadaptercore/omci_ani_config.go
@@ -1170,7 +1170,33 @@
return
}
}
-
+func (oFsm *uniPonAniConfigFsm) handleOmciAniConfigSetFailResponseMessage(ctx context.Context, msgObj *omci.SetResponse) {
+ //If TCONT fails, then we need to revert the allocated TCONT in DB.
+ //Because FSMs are running sequentially, we don't expect the same TCONT hit by another tech-profile FSM while this FSM is running.
+ oFsm.mutexPLastTxMeInstance.RLock()
+ defer oFsm.mutexPLastTxMeInstance.RUnlock()
+ if oFsm.pLastTxMeInstance != nil && msgObj.EntityClass == oFsm.pLastTxMeInstance.GetClassID() &&
+ msgObj.EntityInstance == oFsm.pLastTxMeInstance.GetEntityID() {
+ switch oFsm.pLastTxMeInstance.GetName() {
+ case "TCont":
+ //If this is for TCONT creation(requestEventOffset=0) and this is the first allocation of TCONT(so noone else is using the same TCONT)
+ //We should revert DB
+ if oFsm.requestEventOffset == 0 && !oFsm.tcontSetBefore && oFsm.pUniTechProf.mapPonAniConfig[oFsm.uniTpKey] != nil {
+ logger.Debugw(ctx, "UniPonAniConfigFsm TCONT creation failed on device. Freeing alloc id", log.Fields{"device-id": oFsm.deviceID,
+ "alloc-id": oFsm.pUniTechProf.mapPonAniConfig[oFsm.uniTpKey].tcontParams.allocID, "uni-tp": oFsm.uniTpKey})
+ if pDevEntry := oFsm.pDeviceHandler.getOnuDeviceEntry(ctx, false); pDevEntry != nil {
+ pDevEntry.freeTcont(ctx, oFsm.pUniTechProf.mapPonAniConfig[oFsm.uniTpKey].tcontParams.allocID)
+ } else {
+ logger.Warnw(ctx, "Unable to get device entry! couldn't free tcont",
+ log.Fields{"ME name": oFsm.pLastTxMeInstance.GetName(), "device-id": oFsm.deviceID})
+ }
+ }
+ default:
+ logger.Warnw(ctx, "Unsupported ME name received with error!",
+ log.Fields{"ME name": oFsm.pLastTxMeInstance.GetName(), "result": msgObj.Result, "device-id": oFsm.deviceID})
+ }
+ }
+}
func (oFsm *uniPonAniConfigFsm) handleOmciAniConfigSetResponseMessage(ctx context.Context, msg OmciMessage) {
msgLayer := (*msg.OmciPacket).Layer(omci.LayerTypeSetResponse)
if msgLayer == nil {
@@ -1190,10 +1216,7 @@
log.Fields{"device-id": oFsm.deviceID, "Error": msgObj.Result})
// possibly force FSM into abort or ignore some errors for some messages? store error for mgmt display?
- //FIXME: If setting TCONT fails we need to revert the DB back. Because of the concurency,
- //doing it here may cause a data inconsistency. To fix this problem we need to think on running
- //the FSMs of different UNIs sequentially instead of running them concurrently.
-
+ oFsm.handleOmciAniConfigSetFailResponseMessage(ctx, msgObj)
return
}