[VOL-4396] OMCI lib update to be incorporated into ONU adapter, make use of relaxed decoding

Signed-off-by: mpagenko <michael.pagenkopf@adtran.com>
Change-Id: Ic8bc15ae061af8e27d73879f27bb5b80637a8dea
diff --git a/vendor/github.com/opencord/omci-lib-go/v2/generated/ethernetflowterminationpoint.go b/vendor/github.com/opencord/omci-lib-go/v2/generated/ethernetflowterminationpoint.go
new file mode 100644
index 0000000..d2401d8
--- /dev/null
+++ b/vendor/github.com/opencord/omci-lib-go/v2/generated/ethernetflowterminationpoint.go
@@ -0,0 +1,114 @@
+/*
+ * Copyright (c) 2018 - present.  Boling Consulting Solutions (bcsw.net)
+ * Copyright 2020-present Open Networking Foundation
+
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+
+ * http://www.apache.org/licenses/LICENSE-2.0
+
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ *              https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// EthernetFlowTerminationPointClassID is the 16-bit ID for the OMCI
+// Managed entity Ethernet flow termination point
+const EthernetFlowTerminationPointClassID = ClassID(286) // 0x011e
+
+var ethernetflowterminationpointBME *ManagedEntityDefinition
+
+// EthernetFlowTerminationPoint (Class ID: #286 / 0x011e)
+//	The Ethernet flow TP contains the attributes necessary to originate and terminate Ethernet
+//	frames in the ONU. It is appropriate when transporting pseudowire services via layer-2.
+//	Instances of this ME are created and deleted by the OLT.
+//
+//	Relationships
+//		One Ethernet flow TP ME exists for each distinct pseudowire service that is transported via
+//		layer 2.
+//
+//	Attributes
+//		Managed Entity Id
+//			This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
+//			implicitly linked to a pseudowire TP ME. (R, setbycreate) (mandatory) (2-bytes)
+//
+//		Destination Mac
+//			This attribute specifies the destination MAC address of upstream Ethernet frames. (R,-W,
+//			setbycreate) (mandatory) (6-bytes)
+//
+//		Source Mac
+//			This attribute specifies the near-end MAC address. It is established by nonOMCI means (e.g.,
+//			factory programmed into ONU flash memory) and is included here for information only. (R)
+//			(mandatory) (6-bytes)
+//
+//		Tag Policy
+//			0	untagged frame
+//
+//			1	tagged frame
+//
+//			(R,-W, setbycreate) (mandatory) (1-byte)
+//
+//			This attribute specifies the tagging policy to be applied to upstream Ethernet frames.
+//
+//		Tci
+//			If the tag policy calls for tagging of upstream Ethernet frames, this attribute specifies the
+//			tag control information, which includes the VLAN tag, P bits and CFI bit. (R,-W) (optional)
+//			(2-bytes)
+//
+//		Loopback
+//			This attribute sets the loopback configuration as follows.
+//
+//			0	No loopback
+//
+//			1	Loopback of downstream traffic at MAC client
+//
+//			(R,-W) (mandatory) (1-byte)
+//
+type EthernetFlowTerminationPoint struct {
+	ManagedEntityDefinition
+	Attributes AttributeValueMap
+}
+
+func init() {
+	ethernetflowterminationpointBME = &ManagedEntityDefinition{
+		Name:    "EthernetFlowTerminationPoint",
+		ClassID: 286,
+		MessageTypes: mapset.NewSetWith(
+			Create,
+			Delete,
+			Get,
+			Set,
+		),
+		AllowedAttributeMask: 0xf800,
+		AttributeDefinitions: AttributeDefinitionMap{
+			0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
+			1: MultiByteField("DestinationMac", OctetsAttributeType, 0x8000, 6, toOctets("AAAAAAAA"), mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1),
+			2: MultiByteField("SourceMac", OctetsAttributeType, 0x4000, 6, toOctets("AAAAAAAA"), mapset.NewSetWith(Read), false, false, false, 2),
+			3: ByteField("TagPolicy", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3),
+			4: Uint16Field("Tci", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
+			5: ByteField("Loopback", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5),
+		},
+		Access:  CreatedByOlt,
+		Support: UnknownSupport,
+	}
+}
+
+// NewEthernetFlowTerminationPoint (class ID 286) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewEthernetFlowTerminationPoint(params ...ParamData) (*ManagedEntity, OmciErrors) {
+	return NewManagedEntity(*ethernetflowterminationpointBME, params...)
+}