[VOL-4396] OMCI lib update to be incorporated into ONU adapter, make use of relaxed decoding

Signed-off-by: mpagenko <michael.pagenkopf@adtran.com>
Change-Id: Ic8bc15ae061af8e27d73879f27bb5b80637a8dea
diff --git a/vendor/github.com/opencord/omci-lib-go/v2/generated/physicalpathterminationpointpotsuni.go b/vendor/github.com/opencord/omci-lib-go/v2/generated/physicalpathterminationpointpotsuni.go
new file mode 100644
index 0000000..8b7f6c7
--- /dev/null
+++ b/vendor/github.com/opencord/omci-lib-go/v2/generated/physicalpathterminationpointpotsuni.go
@@ -0,0 +1,190 @@
+/*
+ * Copyright (c) 2018 - present.  Boling Consulting Solutions (bcsw.net)
+ * Copyright 2020-present Open Networking Foundation
+
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+
+ * http://www.apache.org/licenses/LICENSE-2.0
+
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ *              https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// PhysicalPathTerminationPointPotsUniClassID is the 16-bit ID for the OMCI
+// Managed entity Physical path termination point POTS UNI
+const PhysicalPathTerminationPointPotsUniClassID = ClassID(53) // 0x0035
+
+var physicalpathterminationpointpotsuniBME *ManagedEntityDefinition
+
+// PhysicalPathTerminationPointPotsUni (Class ID: #53 / 0x0035)
+//	This ME represents a POTS UNI in the ONU, where a physical path terminates and physical path
+//	level functions (analogue telephony) are performed.
+//
+//	The ONU automatically creates an instance of this ME per port as follows.
+//
+//	o	When the ONU has POTS ports built into its factory configuration.
+//
+//	o	When a cardholder is provisioned to expect a circuit pack of the POTS type.
+//
+//	o	When a cardholder provisioned for plug-and-play is equipped with a circuit pack of the POTS
+//	type. Note that the installation of a plug-and-play card may indicate the presence of POTS ports
+//	via equipment ID as well as type, and indeed may cause the ONU to instantiate a port-mapping
+//	package that specifies POTS ports.
+//
+//	The ONU automatically deletes instances of this ME when a cardholder is neither provisioned to
+//	expect a POTS circuit pack, nor is it equipped with a POTS circuit pack.
+//
+//	Relationships
+//		An instance of this ME is associated with each real or pre-provisioned POTS port. Either a SIP
+//		or a VoIP voice CTP links to the POTS UNI. Status is available from a VoIP line status ME, and
+//		RTP and call control PM may be collected on this point.
+//
+//	Attributes
+//		Managed Entity Id
+//			This attribute uniquely identifies each instance of this ME. This 2-byte number indicates the
+//			physical position of the UNI. The first byte is the slot ID (defined in clause 9.1.5). The
+//			second byte is the port ID, with the range 1..255. (R) (mandatory) (2-bytes)
+//
+//		Administrative State
+//			When the administrative state is set to lock, all user functions of this UNI are blocked, and
+//			alarms, TCAs and AVCs for this ME and all dependent MEs are no longer generated. Selection of a
+//			default value for this attribute is outside the scope of this Recommendation. (R, W) (mandatory)
+//			(1 byte)
+//
+//			This attribute shuts down (2), locks (1) and unlocks (0) the functions performed by this ME. If
+//			the administrative state is set to shut down while the POTS UNI line state is non-idle, no
+//			action is taken until the POTS UNI line state changes to idle, whereupon the administrative
+//			state changes to locked. If the administrative state is set to shut down and the POTS UNI line
+//			state is already idle, the administrative state is immediately set to locked. In both cases, the
+//			transition from shutting down to locked state is signalled with an AVC.
+//
+//		Deprecated
+//			This attribute is not used and should not be supported. (R,-W) (optional) (2-bytes)
+//
+//		Arc
+//			See clause A.1.4.3. (R,-W) (optional) (1-byte)
+//
+//		Arc Interval
+//			See clause A.1.4.3. (R,-W) (optional) (1-byte)
+//
+//		Impedance
+//			2	C1=150 nF, R1=750 Ohm, R2=270 Ohm
+//
+//			3	C1=115 nF, R1=820 Ohm, R2=220 Ohm
+//
+//			4	C1=230 nF, R1=1050 Ohm, R2=320 Ohm
+//
+//			where C1, R1, and R2 are related as shown in Figure 9.9.1-1. Upon ME instantiation, the ONU sets
+//			this attribute to 0. (R,-W) (optional) (1-byte)
+//
+//			This attribute specifies the impedance for the POTS UNI. Valid values include the following.
+//
+//			0	600 Ohm
+//
+//			1	900 Ohm
+//
+//			The following parameter sets from Annex C of [ETSI TS 101 270-1] are also defined:
+//
+//		Transmission Path
+//			This attribute allows setting the POTS UNI either to full-time on-hook transmission (0) or part-
+//			time on-hook transmission (1). Upon ME instantiation, the ONU sets this attribute to 0. (R,-W)
+//			(optional) (1-byte)
+//
+//		Rx Gain
+//			This attribute specifies a gain value for the received signal in the form of a 2s complement
+//			number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the affected signal is
+//			in the D to A direction, towards the telephone set. Upon ME instantiation, the ONU sets this
+//			attribute to 0. (R, W) (optional) (1 byte)
+//
+//		Tx Gain
+//			This attribute specifies a gain value for the transmit signal in the form of a 2s complement
+//			number. Valid values are -120 (12.0-dB) to 60 (+6.0-dB). The direction of the affected signal is
+//			in the A to D direction, away from the telephone set. Upon ME instantiation, the ONU sets this
+//			attribute to 0. (R, W) (optional) (1 byte)
+//
+//		Operational State
+//			This attribute indicates whether the ME is capable of performing its function. Valid values are
+//			enabled (0) and disabled (1). (R) (optional) (1-byte)
+//
+//		Hook State
+//			This attribute indicates the current state of the subscriber line: 0-= on hook, 1-= off hook (R)
+//			(optional) (1-byte)
+//
+//		Pots Holdover Time
+//			This attribute determines the time during which the POTS loop voltage is held up when a LOS or
+//			softswitch connectivity is detected (please refer to the following table for description of
+//			behaviours).. After the specified time elapses, the ONU drops the loop voltage, and may thereby
+//			cause premises intrusion alarm or fire panel circuits to go active. When the ONU ranges
+//			successfully on the PON or softswitch connectivity is restored, it restores the POTS loop
+//			voltage immediately and resets the timer to zero. The attribute is expressed in seconds. The
+//			default value 0 selects the vendor's factory policy. (R,-W) (optional) (2-bytes)
+//
+//		Nominal Feed Voltage
+//			This attribute indicates the designed nominal feed voltage of the POTS loop. It is an absolute
+//			value with resolution 1-V. This attribute does not represent the actual voltage measured on the
+//			loop, which is available through the test command. (R,-W) (optional) (1-byte)
+//
+//		Loss Of Softswitch
+//			This Boolean attribute controls whether the T/R holdover initiation criteria. False disables
+//			loss of softswitch connectivity detection as criteria for initiating the POTS holdover timer.
+//			True enables loss of softswitch connectivity detection as criteria for initiating the POTS
+//			holdover timer. This attribute is optional (if not implemented, the POTS holdover time is
+//			triggered on a LOS when POTS holdover is greater than zero). (R,-W) (optional) (1-byte)
+//
+type PhysicalPathTerminationPointPotsUni struct {
+	ManagedEntityDefinition
+	Attributes AttributeValueMap
+}
+
+func init() {
+	physicalpathterminationpointpotsuniBME = &ManagedEntityDefinition{
+		Name:    "PhysicalPathTerminationPointPotsUni",
+		ClassID: 53,
+		MessageTypes: mapset.NewSetWith(
+			Get,
+			Set,
+			Test,
+		),
+		AllowedAttributeMask: 0xfff8,
+		AttributeDefinitions: AttributeDefinitionMap{
+			0:  Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
+			1:  ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), true, false, false, 1),
+			2:  Uint16Field("Deprecated", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, true, 2),
+			3:  ByteField("Arc", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), true, true, false, 3),
+			4:  ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
+			5:  ByteField("Impedance", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, true, false, 5),
+			6:  ByteField("TransmissionPath", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6),
+			7:  ByteField("RxGain", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7),
+			8:  ByteField("TxGain", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8),
+			9:  ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), true, true, false, 9),
+			10: ByteField("HookState", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10),
+			11: Uint16Field("PotsHoldoverTime", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, true, false, 11),
+			12: ByteField("NominalFeedVoltage", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, true, false, 12),
+			13: ByteField("LossOfSoftswitch", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, Write), false, true, false, 13),
+		},
+		Access:  CreatedByOnu,
+		Support: UnknownSupport,
+	}
+}
+
+// NewPhysicalPathTerminationPointPotsUni (class ID 53) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewPhysicalPathTerminationPointPotsUni(params ...ParamData) (*ManagedEntity, OmciErrors) {
+	return NewManagedEntity(*physicalpathterminationpointpotsuniBME, params...)
+}