Notes on OMCI Alarms Supported by VOLTHA

Below Table describes the list of OMCI Alarm notifications supported by VOLTHA:

ME Class IDAlarm BitMap NoAlarm NameDescription
CircuitPackClassID0Equipment AlarmA failure on an internal interface or failed self-test
CircuitPackClassID2ONU self-test failureFailure of circuit pack autonomous self-test
CircuitPackClassID3Laser end of lifeFailure of transmit laser imminent
CircuitPackClassID4Temperature yellowNo service shutdown at present, but the circuit pack is operating beyond its recommended range
CircuitPackClassID5Temperature redService has been shut down to avoid equipment damage. The operational state of the affected PPTPs indicates the affected services
PhysicalPathTerminationPointEthernetUniClassID0LAN-LOSNo carrier at the Ethernet UNI
OnuGClassID0Equipment AlarmFunctional failure on an internal interface
OnuGClassID6ONU self-test failureONU has failed autonomous self-test
OnuGClassID7Dying gaspONU is powering off imminently due to loss of power to the ONU itself
OnuGClassID8Temperature yellowNo service shutdown at present, but the circuit pack is operating beyond its recommended range
OnuGClassID9Temperature redSome services have been shut down to avoid equipment damage. The operational state of the affected PPTPs indicates the affected services
OnuGClassID10Voltage yellowNo service shutdown at present, but the line power voltage is below its recommended minimum. Service restrictions may be in effect, such as permitting no more than N lines off-hook or ringing at one time
OnuGClassID11Voltage redSome services have been shut down to avoid power collapse. The operational state of the affected PPTPs indicates the affected services
AniGClassID0Low received optical powerReceived downstream optical power below threshold
AniGClassID1High received optical powerReceived downstream optical power above threshold
AniGClassID4Low transmit optical powerTransmit optical power below lower threshold
AniGClassID5High transmit optical powerTransmit optical power above upper threshold
AniGClassID6Laser bias currentLaser bias current above threshold determined by vendor; laser end of life pending