WIP [VOL-2811] - Incorporate preliminary onu-adapter-go code into opencord repo

- reason "discovery-mibsync-complete" reached (via full MibUpload only, received data won't be stored yet)
- first review comments of patchset #4 considered
 (please have a look into our inline-comments in Gerrit to know more about the current state)
- no refactoring done yet

Change-Id: Iac47817f8ce4bd28dd8132f530b0570d57ae99b8
Signed-off-by: Holger Hildebrandt <holger.hildebrandt@adtran.com>
diff --git a/vendor/github.com/opencord/omci-lib-go/generated/reupstreamamplifier.go b/vendor/github.com/opencord/omci-lib-go/generated/reupstreamamplifier.go
new file mode 100644
index 0000000..0f81c6a
--- /dev/null
+++ b/vendor/github.com/opencord/omci-lib-go/generated/reupstreamamplifier.go
@@ -0,0 +1,174 @@
+/*
+ * Copyright (c) 2018 - present.  Boling Consulting Solutions (bcsw.net)
+ * Copyright 2020-present Open Networking Foundation
+
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+
+ * http://www.apache.org/licenses/LICENSE-2.0
+
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+ /*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ *              https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// ReUpstreamAmplifierClassID is the 16-bit ID for the OMCI
+// Managed entity RE upstream amplifier
+const ReUpstreamAmplifierClassID ClassID = ClassID(315)
+
+var reupstreamamplifierBME *ManagedEntityDefinition
+
+// ReUpstreamAmplifier (class ID #315)
+//	This ME organizes data associated with each upstream RE optical amplifier (OA) supported by the
+//	RE. The management ONU automatically creates one instance of this ME for each upstream OA as
+//	follows.
+//
+//	o	When the RE has mid-span PON RE upstream OA ports built into its factory configuration.
+//
+//	o	When a cardholder is provisioned to expect a circuit pack of the mid-span PON RE upstream OA
+//	type.
+//
+//	o	When a cardholder provisioned for plug-and-play is equipped with a circuit pack of the mid-
+//	span PON RE upstream OA type. Note that the installation of a plug-and-play card may indicate
+//	the presence of a mid-span PON RE upstream OA via equipment ID as well as its type attribute,
+//	and indeed may cause the management ONU to instantiate a port-mapping package to specify the
+//	ports precisely.
+//
+//	The management ONU automatically deletes instances of this ME when a cardholder is neither
+//	provisioned to expect a mid-span PON RE upstream OA circuit pack, nor is it equipped with a mid-
+//	span PON RE upstream OA circuit pack.
+//
+//	Relationships
+//		An instance of this ME is associated with an upstream OA, and with an instance of a circuit
+//		pack. If the RE includes OEO regeneration in either direction, the RE upstream amplifier is also
+//		associated with a PPTP RE UNI. Refer to clause-9.14.2 for further discussion.
+//
+//	Attributes
+//		Managed Entity Id
+//			NOTE 1 - This ME ID may be identical to that of a PPTP RE UNI if it shares the same physical
+//			slot and port.
+//
+//		Administrative State
+//			NOTE 2 - Administrative lock of an RE upstream amplifier results in LOS from any downstream
+//			ONUs.
+//
+//		Operational State
+//			Operational state: This attribute indicates whether the ME is capable of performing its
+//			function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte)
+//
+//		Operational Mode
+//			(R,-W) (mandatory) (1-byte)
+//
+//		Arc
+//			ARC:	See clause A.1.4.3. (R,-W) (optional) (1-byte)
+//
+//		Arc Interval
+//			ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte)
+//
+//		Re Downstream Amplifier Pointer
+//			RE downstream amplifier pointer: This attribute points to an RE downstream amplifier instance.
+//			The default value is 0xFFFF, a null pointer. (R,-W) (mandatory) (2-bytes)
+//
+//		Total Optical Receive Signal Level Table
+//			Total optical receive signal level table: This table attribute reports a series of measurements
+//			of time-averaged input upstream optical signal power. The measurement circuit should have a
+//			temporal response similar to a simple 1 pole low pass filter, with an effective time constant on
+//			the order of a GTC frame time. Each table entry has a 2-byte frame counter field (most
+//			significant end), and a 2-byte power measurement field. The frame counter field contains the
+//			least significant 16-bits of the superframe counter received closest to the time of the
+//			measurement. The power measurement field is a 2s-complement integer referred to 1-mW (i.e.,
+//			dBm), with 0.002-dB granularity. The RE equipment should add entries to this table as frequently
+//			as is reasonable. The RE should clear the table once it is read by the OLT. (R) (optional) (4-*
+//			N-bytes, where N is the number of measurements present.)
+//
+//		Per Burst Receive Signal Level Table
+//			Per burst receive signal level table: This table attribute reports the most recent measurement
+//			of received burst upstream optical signal power. Each table entry has a 2-byte ONU-ID field
+//			(most significant end), and a 2-byte power measurement field. The power measurement field is a
+//			2s-complement integer referred to 1-mW (i.e.,-dBm), with 0.002-dB granularity. (R) (optional)
+//			(4-* N-bytes, where N is the number of distinct ONUs connected to the S'/R' interface.)
+//
+//		Lower Receive Optical Threshold
+//			Lower receive optical threshold: This attribute specifies the optical level that the RE uses to
+//			declare the low received optical power alarm. Valid values are -127-dBm (coded as 254) to 0-dBm
+//			(coded as 0) in 0.5-dB increments. The default value 0xFF selects the RE's internal policy.
+//			(R,-W) (optional) (1-byte)
+//
+//		Upper Receive Optical Threshold
+//			Upper receive optical threshold: This attribute specifies the optical level that the RE uses to
+//			declare the high received optical power alarm. Valid values are -127-dBm (coded as 254) to 0-dBm
+//			(coded as 0) in 0.5-dB increments. The default value 0xFF selects the RE's internal policy.
+//			(R,-W) (optional) (1-byte)
+//
+//		Transmit Optical Signal Level
+//			Transmit optical signal level: This attribute reports the current measurement of the mean
+//			optical launch power of the upstream OA. Its value is a 2s-complement integer referred to 1-mW
+//			(i.e., dBm), with 0.002-dB granularity. (R) (optional) (2-bytes)
+//
+//		Lower Transmit Optical Threshold
+//			Lower transmit optical threshold: This attribute specifies the minimum mean optical launch power
+//			that the RE uses to declare the low transmit optical power alarm. Its value is a 2s-complement
+//			integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects
+//			the RE's internal policy. (R,-W) (optional) (1-byte)
+//
+//		Upper Transmit Optical Threshold
+//			Upper transmit optical threshold: This attribute specifies the maximum mean optical launch power
+//			that the RE uses to declare the high transmit optical power alarm. Its value is a 2s complement
+//			integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects
+//			the RE's internal policy. (R,-W) (optional) (1-byte)
+//
+type ReUpstreamAmplifier struct {
+	ManagedEntityDefinition
+	Attributes AttributeValueMap
+}
+
+func init() {
+	reupstreamamplifierBME = &ManagedEntityDefinition{
+		Name:    "ReUpstreamAmplifier",
+		ClassID: 315,
+		MessageTypes: mapset.NewSetWith(
+			Get,
+			GetNext,
+			Set,
+		),
+		AllowedAttributeMask: 0xfff8,
+		AttributeDefinitions: AttributeDefinitionMap{
+			0:  Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
+			1:  ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1),
+			2:  ByteField("OperationalState", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, true, false, 2),
+			3:  ByteField("OperationalMode", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, false, false, 3),
+			4:  ByteField("Arc", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), true, true, false, 4),
+			5:  ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, true, false, 5),
+			6:  Uint16Field("ReDownstreamAmplifierPointer", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, false, false, 6),
+			7:  TableField("TotalOpticalReceiveSignalLevelTable", TableAttributeType, 0x0200, TableInfo{nil, 4}, mapset.NewSetWith(Read), false, true, false, 7),
+			8:  TableField("PerBurstReceiveSignalLevelTable", TableAttributeType, 0x0100, TableInfo{nil, 4}, mapset.NewSetWith(Read), false, true, false, 8),
+			9:  ByteField("LowerReceiveOpticalThreshold", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, true, false, 9),
+			10: ByteField("UpperReceiveOpticalThreshold", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), false, true, false, 10),
+			11: Uint16Field("TransmitOpticalSignalLevel", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11),
+			12: ByteField("LowerTransmitOpticalThreshold", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, true, false, 12),
+			13: ByteField("UpperTransmitOpticalThreshold", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, Write), false, true, false, 13),
+		},
+		Access:  CreatedByOnu,
+		Support: UnknownSupport,
+	}
+}
+
+// NewReUpstreamAmplifier (class ID 315) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewReUpstreamAmplifier(params ...ParamData) (*ManagedEntity, OmciErrors) {