[VOL-3893] Added TT Failure Scenarios Suite to Jenkins HW Periodic Run
Change-Id: Ibeb31c8dc6e84e5aff7aa33698d54561e5b52b5a
diff --git a/tests/tt-workflow/Voltha_TT_FailureScenarios.robot b/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
index 88d80bd..de0ffd6 100755
--- a/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
+++ b/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
@@ -49,7 +49,7 @@
${of_id} 0
${logical_id} 0
${has_dataplane} True
-${teardown_device} False
+${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
@@ -61,7 +61,7 @@
Verify restart openonu-adapter container after subscriber provisioning for TT
[Documentation] Restart openonu-adapter container after VOLTHA is operational.
... Prerequisite : ONUs are authenticated and pingable.
- [Tags] functional Restart-OpenOnu-TT
+ [Tags] functionalTT Restart-OpenOnu-TT
[Setup] Start Logging Restart-OpenOnu-TT
[Teardown] Run Keywords Collect Logs
... AND Stop Logging Restart-OpenOnu-TT
@@ -99,3 +99,4 @@
Teardown Suite
[Documentation] Tear down steps for the suite
Run Keyword If ${has_dataplane} Clean Up Linux
+ Run Keyword If ${teardown_device} Delete All Devices and Verify
diff --git a/tests/tt-workflow/Voltha_TT_PODTests.robot b/tests/tt-workflow/Voltha_TT_PODTests.robot
index 955af23..9028dc4 100644
--- a/tests/tt-workflow/Voltha_TT_PODTests.robot
+++ b/tests/tt-workflow/Voltha_TT_PODTests.robot
@@ -49,7 +49,7 @@
${of_id} 0
${logical_id} 0
${has_dataplane} True
-${teardown_device} False
+${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
@@ -121,3 +121,4 @@
Teardown Suite
[Documentation] Tear down steps for the suite
Run Keyword If ${has_dataplane} Clean Up Linux
+ Run Keyword If ${teardown_device} Delete All Devices And Verify