blob: 32287834be868f961d649bf5a3d338790cd3a48f [file] [log] [blame]
# Copyright 2020 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
*** Settings ***
Documentation Test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!)
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
Test Teardown Teardown
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../variables/variables.robot
*** Variables ***
${namespace} voltha
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# state to test variable, can be passed via the command line too, valid values: 1-6
# 1 -> activating-onu
# 2 -> starting-openomci
# 3 -> discovery-mibsync-complete
# 4 -> initial-mib-downloaded
# 5 -> tech-profile-config-download-success
# 6 -> omci-flows-pushed
# example: -v state2test:5
# example: -v state2test:omci-flows-pushed
${state2test} 6
# test mode variable, can be passed via the command line too, valid values: SingleState, Up2State, SingleStateTime
# example: -v testmode:SingleStateTime
${testmode} SingleState
# used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM
# example: -v techprofile:1T4GEM
${techprofile} default
# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
# example: -v debugmode:True
${debugmode} False
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
# example: -v pausebeforecleanup:True
${pausebeforecleanup} False
# if True some outputs to console are done during running tests e.g. long duration flow test
# example: -v print2console:True
${print2console} False
${data_dir} ../data
*** Test Cases ***
ONU State Test
[Documentation] Validates the ONU Go adapter states
[Tags] sanityOnuGo StateTestOnuGo
[Setup] Run Keywords Start Logging ONUStateTest
... AND Setup Test
Run Keyword If ${has_dataplane} Clean Up Linux
FOR ${I} IN RANGE 0 ${num_olts}
#get olt serial number
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Enable Device ${olt_device_id}
END
${timeStart} = Get Current Date
Set Global Variable ${timeStart}
Run Keyword If "${testmode}"=="SingleState" Do ONU Single State Test
... ELSE IF "${testmode}"=="Up2State" Do ONU Up To State Test
... ELSE IF "${testmode}"=="SingleStateTime" Do ONU Single State Test Time
... ELSE Fail The testmode (${testmode}) is not valid!
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUStateTest
Check Loaded Tech Profile
[Documentation] Validates the loaded Tech Profile
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
... Check will be executed only the reached ONU state is 5 (tech-profile-config-download-success) or higher
[Tags] functionalOnuGo CheckTechProfileOnuGo
[Setup] Start Logging ONUCheckTechProfile
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Check Tech Profile
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUCheckTechProfile
Onu Port Check
[Documentation] Validates that all the UNI ports show up in ONOS
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo PortTestOnuGo
[Setup] Start Logging ONUPortTest
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Onu Port Check
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUPortTest
Onu Etcd Data Check
[Documentation] Validates ONU data stored in ETCD
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo EtcdDataOnuGo
[Setup] Start Logging ONUEtcdDataTest
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Onu Etcd Data Check
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUEtcdDataTest
Onu Flow Check
[Documentation] Validates the onu flows in ONOS and Voltha
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo FlowTestOnuGo
[Setup] Start Logging ONUFlowTest
Run Keyword If '${onu_state}'=='omci-flows-pushed' Do Onu Flow Check
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUFlowTest
Disable Enable Onu Device
[Documentation] Disables/enables ONU Device and check states
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo DisableEnableOnuGo
[Setup] Start Logging DisableEnableONUDevice
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Disable Enable Onu Test
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging DisableEnableONUDevice
Power Off Power On Onu Device
[Documentation] Power off and Power on of all ONU Devices and check state
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo PowerOffPowerOnOnuGo
[Setup] Start Logging PowerOffPowerOnONUDevice
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Power Off Power On Onu Device
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging PowerOffPowerOnONUDevice
Soft Reboot Onu Device
[Documentation] Reboots softly all ONU Devices and check state
... Assuming that ONU State Test was executed where all the ONUs are reached the expected state!
[Tags] functionalOnuGo SoftRebootOnuGo
[Setup] Start Logging SoftRebootONUDevice
Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed'
... Do Soft Reboot Onu Device
... ELSE Pass Execution ${skip_message} skipped
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging SoftRebootONUDevice
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
${LogInfo}= Catenate
... \r\nPassed arguments:
... state2test:${state2test}, testmode:${testmode}, techprofile:${techprofile},
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
... print2console:${print2console}
Log ${LogInfo} console=yes
Common Test Suite Setup
# prepare skip message in yellow for console log
${skip}= Evaluate "\\033[33mSKIP\\033[0m"
${skipped}= Evaluate "\\033[33m${SPACE*14} ===> Test case above was skipped! <=== ${SPACE*15}\\033[0m"
${skip_message} Catenate ${skipped} | ${skip} |
Set Suite Variable ${skip_message}
${all_onu_timeout}= Run Keyword If ${num_all_onus}>4 Calculate Timeout ${timeout}
... ELSE Set Variable ${timeout}
Set Suite Variable ${all_onu_timeout}
${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
Set Suite Variable ${techprofile}
Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM)
... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM
... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM
... ELSE Fail The TechProfile (${techprofile}) is not valid!
${onos_ssh_connection} Open ONOS SSH Connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
Set Suite Variable ${onos_ssh_connection}
# map the passed onu state to reached and make it visible for test suite
${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}=
... Map State ${state2test}
Set Suite Variable ${admin_state}
Set Suite Variable ${oper_status}
Set Suite Variable ${connect_status}
Set Suite Variable ${onu_state_nb}
Set Suite Variable ${onu_state}
# delete etcd MIB Template Data
Delete MIB Template Data
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
Validate Onu Data In Etcd 0
Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} 0 BBSM ${timeout}
Close All ONOS SSH Connections
Remove Tech Profile
Setup Test
[Documentation] Pre-test Setup
#test for empty device list
Test Empty Device List
Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up
... ${olt_ssh_ip} ${olt_user} ${olt_pass}
Run Keyword If ${has_dataplane} Sleep 60s
# Create a list of olt ids (logical and device_id)
${olt_ids} Create List
FOR ${I} IN RANGE 0 ${num_olts}
#create/preprovision device
${olt_device_id}= Create Device ${list_olts}[${I}][ip] ${OLT_PORT}
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id}
Sleep 5s
${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id}
... of_id ${of_id} sn ${olt_serial_number}
Append To List ${olt_ids} ${olt}
END
Set Global Variable ${olt_ids}
Do ONU Up To State Test
[Documentation] This keyword performs Up2State Test
... All states up to the passed have to be checked
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Run Keyword If ${onu_state_nb}>=1
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVATING REACHABLE
... ${src['onu']} onu=True onu_reason=activating-onu
Run Keyword If ${onu_state_nb}>=2
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVATING REACHABLE
... ${src['onu']} onu=True onu_reason=starting-openomci
Run Keyword If ${onu_state_nb}>=3
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVATING REACHABLE
... ${src['onu']} onu=True onu_reason=discovery-mibsync-complete
Run Keyword If ${onu_state_nb}>=4
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=initial-mib-downloaded
Run Keyword If ${onu_state_nb}>=5
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=tech-profile-config-download-success
Run Keyword If ${onu_state_nb}>=6
... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
END
Do ONU Single State Test
[Documentation] This keyword performs SingleState Test
... Only the passed state has to be checked
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate Device ${admin_state} ${oper_status} ${connect_status}
... ${src['onu']} onu=True onu_reason=${onu_state}
END
Do ONU Single State Test Time
[Documentation] This keyword performs SingleState Test with calculate running time
... Only the passed state has to be checked and the duration each single onu adapter needed
... will be calculated and printed out
#${ListfinishedONUs} Create List
#Set Global Variable ${ListfinishedONUs}
Create File ONU_Startup_Time.txt This file contains the startup times of all ONUs.
${list_onus} Create List
Build ONU SN List ${list_onus}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms
... Validate ONU Devices MIB State With Duration
... ${onu_state} ${list_onus} ${timeStart} print2console=${print2console}
... output_file=ONU_Startup_Time.txt
Do Onu Port Check
[Documentation] Check that all the UNI ports show up in ONOS
Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} ${num_all_onus} BBSM
Do Onu Etcd Data Check
[Documentation] Check Onu data stored in etcd
Validate Onu Data In Etcd
Do Onu Flow Check
[Documentation] This keyword iterate all OLTs and performs Do Onu Flow Checks Per OLT
# Check and store vlan rules
${firstvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${onu_count}= Set Variable ${list_olts}[${J}][onucount]
${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
... ${olt_serial_number}
Set Global Variable ${of_id}
# Verify Default Meter in ONOS (valid only for ATT)
Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${onu_count}
END
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${onu_count}= Set Variable ${list_olts}[${J}][onucount]
${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
... ${olt_serial_number}
Set Global Variable ${of_id}
${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get NNI Port in ONOS ${of_id}
Set Global Variable ${nni_port}
# Verify Default Meter in ONOS (valid only for ATT)
Do Onu Flow Check Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count}
END
#log flows for verification
${flowsresult}= Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT} flows -s
log ${flowsresult}
#check for previous state is kept (normally omci-flows-pushed)
Sleep 10s
Run Keyword And Continue On Failure Current State Test All Onus ${state2test}
${secondvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd nbofcookieslice=3
... prevvlanrules=${firstvlanrules}
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${onu_count}= Set Variable ${list_olts}[${J}][onucount]
${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
... ${olt_serial_number}
Set Global Variable ${of_id}
${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get NNI Port in ONOS ${of_id}
Set Global Variable ${nni_port}
# Verify Default Meter in ONOS (valid only for ATT)
Do Onu Subscriber Remove Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count}
END
#check for previous state is kept (normally omci-flows-pushed)
Sleep 10s
Run Keyword If ${print2console} Log \r\nStart State Test All Onus. console=yes
Run Keyword And Continue On Failure Current State Test All Onus ${state2test}
Run Keyword If ${print2console} Log \r\nFinished State Test All Onus. console=yes
Run Keyword And Continue On Failure Validate Vlan Rules In Etcd prevvlanrules=${firstvlanrules}
... setvidequal=True
Do Onu Subscriber Add Per OLT
[Documentation] Add Subscriber per OLT
[Arguments] ${of_id} ${olt_serial_number} ${num_onus}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
Run Keyword If ${print2console} Log \r\n[${I}] volt-add-subscriber-access ${of_id} ${onu_port}.
... console=yes
END
Do Onu Flow Check Per OLT
[Documentation] Checks all ONU flows show up in ONOS and Voltha
[Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
# Verify subscriber access flows are added for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
${logoutput} Catenate \r\n[${I}] Verify Subscriber Access Flows Added For
... ONU ${of_id} ${onu_port} ${src['c_tag']} ${src['s_tag']}.
Run Keyword If ${print2console} Log ${logoutput} console=yes
END
Do Onu Subscriber Remove Per OLT
[Documentation] Removes per OLT subscribers in ONOS and Voltha
[Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-remove-subscriber-access ${of_id} ${onu_port}
Run Keyword If ${print2console} Log \r\n[${I}] volt-remove-subscriber-access ${of_id} ${onu_port}.
... console=yes
END
Do Check Tech Profile
[Documentation] This keyword checks the loaded TechProfile
${namespace}= Set Variable default
${podname}= Set Variable etcd
${stackname}= Get Stack Name
${commandget} Catenate
... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/${stackname}/technology_profiles/XGS-PON/64'
${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
${num_gem_ports}= Set Variable 1
${num_gem_ports}= Set Variable If
... "${techprofile}"=="default" 1
... "${techprofile}"=="1T4GEM" 4
... "${techprofile}"=="1T8GEM" 8
@{resultList} Split String ${result} separator=,
${num_of_count_matches}= Get Match Count ${resultList} "num_gem_ports": ${num_gem_ports}
... whitespace_insensitive=True
${num_of_expected_matches}= Evaluate ${num_all_onus}
Should Be Equal As Integers ${num_of_expected_matches} ${num_of_count_matches}
... TechProfile (${TechProfile}) not loaded correctly:${num_of_count_matches} of ${num_of_expected_matches}
Do Disable Enable Onu Test
[Documentation] This keyword disables/enables all onus and checks the states.
[Arguments] ${state2check}=${state2test} ${checkstatebeforedisable}=True
... ${state2checkafterdisable}=tech-profile-config-delete-success
Run Keyword If ${checkstatebeforedisable} Current State Test All Onus ${state2check}
Disable Onu Device
${alternative_onu_reason}= Set Variable If
... '${state2checkafterdisable}'=='tech-profile-config-delete-success' omci-flows-deleted
... '${state2checkafterdisable}'=='omci-admin-lock' tech-profile-config-delete-success ${EMPTY}
${alternativeonustates}= Create List ${alternative_onu_reason}
Current State Test All Onus ${state2checkafterdisable} alternativeonustate=${alternativeonustates}
Log Ports
#check no port is enabled in ONOS
Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} 0 BBSM
Enable Onu Device
Current State Test All Onus ${state2check}
Log Ports onlyenabled=True
#check that all the UNI ports show up in ONOS again
Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} ${num_all_onus} BBSM
Do Power Off Power On Onu Device
[Documentation] This keyword power off/on all onus and checks the states.
Power Off ONU Device ${namespace}
Sleep 5s
${alternativeonustates}= Create List omci-flows-deleted
Current State Test All Onus tech-profile-config-delete-success
... ENABLED DISCOVERED UNREACHABLE alternativeonustate=${alternativeonustates}
Power On ONU Device ${namespace}
Current State Test All Onus ${state2test}
Do Soft Reboot Onu Device
[Documentation] This keyword reboots softly all onus and checks the states.
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
Reboot ONU ${onu_device_id} False
END
${alternativeonustates}= Create List omci-flows-deleted
Run Keyword Unless ${has_dataplane} Current State Test All Onus tech-profile-config-delete-success
... ENABLED DISCOVERED REACHABLE alternativeonustate=${alternativeonustates}
Sleep 5s
Run Keyword Unless ${has_dataplane} Do Disable Enable Onu Test checkstatebeforedisable=False
... state2checkafterdisable=omci-admin-lock
Run Keyword If ${has_dataplane} Current State Test All Onus omci-flows-pushed
Do Onu Port Check