[VOL-4081] verifying ANI-G Test framework

Change-Id: Iad4d415dece744d8a00a39ad8360931f0499fd01
diff --git a/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot b/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot
new file mode 100755
index 0000000..4c4953a
--- /dev/null
+++ b/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot
@@ -0,0 +1,87 @@
+# Copyright 2021 - present Open Networking Foundation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+# FIXME Can we use the same test against BBSim and Hardware?
+
+*** Settings ***
+Documentation     Test of open ONU go adapter OMCI Get
+Suite Setup       Setup Suite
+Test Setup        Setup
+Test Teardown     Teardown
+Suite Teardown    Teardown Suite
+Library           Collections
+Library           String
+Library           OperatingSystem
+Library           XML
+Library           RequestsLibrary
+Library           ../../libraries/DependencyLibrary.py
+Resource          ../../libraries/onos.robot
+Resource          ../../libraries/voltctl.robot
+Resource          ../../libraries/voltha.robot
+Resource          ../../libraries/utils.robot
+Resource          ../../libraries/k8s.robot
+Resource          ../../variables/variables.robot
+Resource          ../../libraries/power_switch.robot
+
+*** Variables ***
+${namespace}      voltha
+${timeout}        60s
+${of_id}          0
+${logical_id}     0
+${has_dataplane}    True
+${external_libs}    True
+${teardown_device}    True
+${scripts}        ../../scripts
+# Per-test logging on failure is turned off by default; set this variable to enable
+${container_log_dir}    ${None}
+# determines the environment workflow: DT, TT or ATT (default)
+# example: -v workflow:DT
+${workflow}    ATT
+# logging flag to enable Collect Logs, can be passed via the command line too
+# example: -v logging:True
+${logging}    False
+${data_dir}    ../data
+
+*** Test Cases ***
+ANI-G Test
+    [Documentation]    Validates ANI-G output of ONU device(s):
+    [Tags]    functionalOnuGo    AniGTest
+    [Setup]    Start Logging    AniGTest
+    FOR    ${I}    IN RANGE    0    ${num_all_onus}
+        ${src}=    Set Variable    ${hosts.src[${I}]}
+        ${onu_device_id}=    Get Device ID From SN    ${src['onu']}
+        ${voltctl_commad} =    Catenate    SEPARATOR=
+        ...    voltctl device getextval onu_pon_optical_info ${onu_device_id}
+        ${rc}    ${output}=    Run and Return Rc and Output    ${voltctl_commad}
+        Should Be Equal As Integers    ${rc}    0
+        Should Contain    ${output}    POWER_FEED_VOLTAGE__VOLTS:
+        Should Contain    ${output}    3.26
+        Should Contain    ${output}    RECEIVED_OPTICAL_POWER__dBm:
+        Should Contain    ${output}    MEAN_OPTICAL_LAUNCH_POWER__dBm:
+        Should Contain    ${output}    LASER_BIAS_CURRENT__mA:
+        Should Contain    ${output}    TEMPERATURE__Celsius:
+    END
+    [Teardown]    Run Keywords    Run Keyword If    ${logging}    Collect Logs
+    ...           AND    Stop Logging    SanityTestOnuGo
+
+*** Keywords ***
+Setup Suite
+    [Documentation]    Set up the test suite inclusive enable device and sanity test of given workflow
+    Common Test Suite Setup
+    ${switch_type}=    Get Variable Value    ${web_power_switch.type}
+    Run Keyword If  "${switch_type}"!=""    Set Global Variable    ${powerswitch_type}    ${switch_type}
+    Setup
+    Run Keyword If    ${has_dataplane}    Clean Up Linux
+    Run Keyword If    "${workflow}"=="DT"    Perform Sanity Test DT
+    ...    ELSE IF    "${workflow}"=="TT"    Perform Sanity Tests TT
+    ...    ELSE       Perform Sanity Test