[VOL-3246] Added RebootONUs before the test executions, and ONURestore towards end of executions
Change-Id: Ie228afdd8656e15d89711ea5415bd9960fdc1a22
diff --git a/tests/dt-workflow/Voltha_DT_PODTests.robot b/tests/dt-workflow/Voltha_DT_PODTests.robot
index 304ebac..e542352 100644
--- a/tests/dt-workflow/Voltha_DT_PODTests.robot
+++ b/tests/dt-workflow/Voltha_DT_PODTests.robot
@@ -31,6 +31,7 @@
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../variables/variables.robot
+Resource ../../libraries/power_switch.robot
*** Variables ***
${POD_NAME} flex-ocp-cord
@@ -61,6 +62,24 @@
${container_log_dir} ${None}
*** Test Cases ***
+Reboot DT ONUs Physically
+ [Documentation] This test reboots ONUs physically before execution all the tests
+ ... Test case runs only on the PODs that are configured with PowerSwitch that
+ ... controls the power off/on ONUs/OLT remotely (simulating a physical reboot)
+ [Tags] functional PowerSwitch RebootAllDTONUs
+ [Setup] Start Logging RebootAllDTONUs
+ [Teardown] Run Keywords Collect Logs
+ ... AND Stop Logging RebootAllDTONUs
+ Power Switch Connection Suite ${web_power_switch.ip} ${web_power_switch.user} ${web_power_switch.password}
+ FOR ${I} IN RANGE 0 ${num_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ Disable Switch Outlet ${src['power_switch_port']}
+ Sleep 60s
+ Enable Switch Outlet ${src['power_switch_port']}
+ Sleep 60s
+ END
+
Sanity E2E Test for OLT/ONU on POD for DT
[Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used
@@ -475,7 +494,10 @@
[Documentation] Set up the test suite
Common Test Suite Setup
#Restore all ONUs
- Run Keyword If ${has_dataplane} RestoreONUs ${num_onus}
+ #Run Keyword If ${has_dataplane} RestoreONUs ${num_onus}
+ #power_switch.robot needs it to support different vendor's power switch
+ ${switch_type}= Get Variable Value ${web_power_switch.type}
+ Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type}
Clear All Devices Then Create New Device
[Documentation] Remove any devices from VOLTHA and ONOS