[VOL-2923] Verify Subscriber Flows Added for ONUs on ONOS
Change-Id: Id5270abc041c1678866d5080b567cf0cd51a2dab
diff --git a/tests/functional/Voltha_FailureScenarios.robot b/tests/functional/Voltha_FailureScenarios.robot
index bc07158..7d5348c 100644
--- a/tests/functional/Voltha_FailureScenarios.robot
+++ b/tests/functional/Voltha_FailureScenarios.robot
@@ -97,6 +97,10 @@
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
@@ -276,6 +280,10 @@
# Add subscriber access and verify that DHCP completes to ensure system is still functioning properly
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
@@ -288,7 +296,6 @@
Verify restart ofagent container after subscriber is provisioned
[Documentation] Restart ofagent container after VOLTHA is operational.
... Prerequisite : ONUs are authenticated and pingable.
- #TODO: remove "notready" tag once olt reboot and ofagent restart work items are done
[Tags] functional VOL-2409 ofagentRestart
[Setup] Run Keywords Announce Message START TEST ofagentRestart
... AND Start Logging ofagentRestart
@@ -339,6 +346,10 @@
# Verify DHCP-Allocations
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Validate Subscriber DHCP Allocation ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
# Verify Ping
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Check Ping True
... ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']} ${src['ip']}
@@ -420,6 +431,10 @@
# Verify that no pending flows exist for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
@@ -495,6 +510,10 @@
# Add subscriber access and verify that DHCP completes to ensure system is still functioning properly
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
@@ -530,6 +549,10 @@
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
# Verify pings are successful after reboot on the current ONU
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s