[VOL-2731] TT sanity test
Change-Id: Ic36eb4da3d0016d89da1b1f8d2f77e8b719cad0c
diff --git a/libraries/utils.robot b/libraries/utils.robot
index 39173e8..688b9a2 100644
--- a/libraries/utils.robot
+++ b/libraries/utils.robot
@@ -258,6 +258,43 @@
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONU Flows
... ${List_ONU_Serial} ${onu_flows}
+Perform Sanity Test TT
+ [Documentation] This keyword performs Sanity Test Procedure for TT Workflow
+ ... Sanity test performs dhcp and pings (without EAPOL and DHCP flows) for all the ONUs given for the POD
+ ... This keyword can be used to call in any other tests where sanity check is required
+ ... and avoids duplication of code.
+ ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS ${olt_serial_number}
+ Set Global Variable ${of_id}
+ ${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get NNI Port in ONOS ${of_id}
+ Set Global Variable ${nni_port}
+ FOR ${I} IN RANGE 0 ${num_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ ${onu_device_id}= Get Device ID From SN ${src['onu']}
+ ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get ONU Port in ONOS ${src['onu']} ${of_id}
+ # Check ONU port is Enabled in ONOS
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 120s 2s
+ ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
+ ... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-add-subscriber-access ${of_id} ${onu_port}
+ Sleep 30s
+ # Verify ONU state in voltha
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
+ ... ENABLED ACTIVE REACHABLE
+ ... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
+ Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
+ ... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
+ ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ ... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
+ ... ${dst['container_name']}
+ Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
+ Run Keyword and Ignore Error Collect Logs
+ END
+
Setup
[Documentation] Pre-test Setup
#test for empty device list