[VOL-4000] Added ONU and OLT Physical Reboot TC for TT
Change-Id: I072bde2e7fd9c9eb6af1227be45a03ded7b1de55
diff --git a/Makefile b/Makefile
index 4d8b409..68773e4 100755
--- a/Makefile
+++ b/Makefile
@@ -308,7 +308,7 @@
bbsim-failurescenarios-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
bbsim-failurescenarios-dt: voltha-dt-test
-bbsim-failurescenarios-tt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
+bbsim-failurescenarios-tt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOltRebootTT
bbsim-failurescenarios-tt: ROBOT_FILE := Voltha_TT_FailureScenarios.robot
bbsim-failurescenarios-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
bbsim-failurescenarios-tt: voltha-tt-test
diff --git a/tests/tt-workflow/Voltha_TT_FailureScenarios.robot b/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
index d3e3fc1..065a403 100755
--- a/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
+++ b/tests/tt-workflow/Voltha_TT_FailureScenarios.robot
@@ -58,6 +58,115 @@
${suppressaddsubscriber} True
*** Test Cases ***
+Verify ONU after Rebooting Physically for TT
+ [Documentation] Test the ONU functionality by physically turning on/off ONU.
+ ... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityTT test was executed)
+ ... Test case runs only on the PODs that are configured with PowerSwitch that
+ ... controls the power off/on ONUs/OLT remotely (simulating a physical reboot)
+ [Tags] functionalTT PowerSwitchOnuRebootTT PowerSwitch
+ [Setup] Start Logging RebootOnu_PowerSwitch_TT
+ [Teardown] Run Keywords Collect Logs
+ ... AND Stop Logging RebootOnu_PowerSwitch_TT
+ ... AND Delete All Devices and Verify
+ # Add OLT device
+ Setup
+ # Performing Sanity Test to make sure subscribers are all DHCP and pingable
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Tests TT
+ Power Switch Connection Suite ${web_power_switch.ip} ${web_power_switch.user} ${web_power_switch.password}
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ FOR ${I} IN RANGE 0 ${num_all_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ ${service_type}= Get Variable Value ${src['service_type']} "null"
+ ${of_id}= Get ofID From OLT List ${src['olt']}
+ ${onu_device_id}= Get Device ID From SN ${src['onu']}
+ ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get ONU Port in ONOS ${src['onu']} ${of_id}
+ # Disable Power Switch
+ Disable Switch Outlet ${src['power_switch_port']}
+ # TODO: Add verification for MCAST
+ Run Keyword If ${has_dataplane} and '${service_type}' != 'mcast' Run Keyword And Continue On Failure
+ ... Wait Until Keyword Succeeds 60s 2s
+ ... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
+ ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ # Remove Subscriber Access (To replicate TT workflow)
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ ... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
+ Sleep 5s
+ # Enable Power Switch
+ Enable Switch Outlet ${src['power_switch_port']}
+ # Check ONU port is Enabled in ONOS
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 120s 2s
+ ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
+ ... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify ONU state in voltha
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 360s 5s Validate Device
+ ... ENABLED ACTIVE REACHABLE
+ ... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ Run Keyword If ${has_dataplane} and '${service_type}' != 'mcast'
+ ... Run Keyword And Continue On Failure Validate DHCP and Ping True
+ ... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
+ ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ ... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
+ ... ${dst['container_name']}
+ ... ELSE IF ${has_dataplane} and '${service_type}' == 'mcast' Run Keyword And Continue On Failure
+ ... Wait Until Keyword Succeeds ${timeout} 2s Sanity Test TT MCAST one ONU ${src}
+ ... ${dst} ${suppressaddsubscriber}
+ END
+
+Verify OLT after Rebooting Physically for TT
+ [Documentation] Test the physical reboot of the OLT
+ ... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityTT test was executed)
+ ... Test performs a physical reboot, performs "reboot" from the OLT CLI
+ [Tags] functionalTT PhysicalOltRebootTT
+ [Setup] Start Logging RebootOlt_Physical_TT
+ [Teardown] Run Keywords Collect Logs
+ ... AND Stop Logging RebootOlt_Physical_TT
+ ... AND Delete All Devices and Verify
+ # Add OLT device
+ Setup
+ # Performing Sanity Test to make sure subscribers are all DHCP and pingable
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Tests TT
+ # Reboot the OLT from the OLT CLI
+ FOR ${I} IN RANGE 0 ${olt_count}
+ ${olt_user}= Get From Dictionary ${list_olts}[${I}] user
+ ${olt_pass}= Get From Dictionary ${list_olts}[${I}] pass
+ ${olt_ssh_ip}= Get From Dictionary ${list_olts}[${I}] sship
+ ${olt_serial_number}= Get From Dictionary ${list_olts}[${I}] sn
+ ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
+ Run Keyword If ${has_dataplane} Login And Run Command On Remote System
+ ... reboot ${olt_ssh_ip} ${olt_user} ${olt_pass} prompt=#
+ END
+ FOR ${I} IN RANGE 0 ${num_all_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ ${service_type}= Get Variable Value ${src['service_type']} "null"
+ # TODO: Add verification for MCAST
+ Run Keyword If ${has_dataplane} and '${service_type}' != 'mcast' Run Keyword And Continue On Failure
+ ... Wait Until Keyword Succeeds 60s 2s
+ ... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
+ ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ END
+ # Wait for the OLT to come back up
+ FOR ${I} IN RANGE 0 ${olt_count}
+ ${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
+ ${olt_user}= Get From Dictionary ${list_olts}[${I}] user
+ ${olt_pass}= Get From Dictionary ${list_olts}[${I}] pass
+ ${olt_ssh_ip}= Get From Dictionary ${list_olts}[${I}] sship
+ ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
+ Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s
+ ... Check Remote System Reachability True ${olt_ssh_ip}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 360s 5s
+ ... Validate OLT Device ENABLED ACTIVE
+ ... REACHABLE ${olt_serial_number}
+ END
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Tests TT
+
Verify restart openonu-adapter container after subscriber provisioning for TT
[Documentation] Restart openonu-adapter container after VOLTHA is operational.
... Prerequisite : ONUs are authenticated and pingable.