[VOL-4041] Migration to single ONOS SSH connection
Change-Id: I91f5f3c96585097486bc862118d8753bf4b30cba
diff --git a/tests/functional/Voltha_PODTests.robot b/tests/functional/Voltha_PODTests.robot
old mode 100644
new mode 100755
index d59a075..dea6d12
--- a/tests/functional/Voltha_PODTests.robot
+++ b/tests/functional/Voltha_PODTests.robot
@@ -143,7 +143,7 @@
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
@@ -151,7 +151,7 @@
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
@@ -186,7 +186,7 @@
... ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
Run Keyword And Ignore Error Login And Run Command On Remote System ps -ef | grep dhclient ${src['ip']}
... ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Sleep 15s
Run Keyword And Ignore Error Login And Run Command On Remote System ps -ef | grep dhclient ${src['ip']}
@@ -202,7 +202,7 @@
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
... ${dst['container_name']}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
@@ -239,7 +239,7 @@
... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
Disable Device ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Test Devices Disabled in VOLTHA Id=${onu_device_id}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s Check Ping
@@ -255,7 +255,7 @@
... ${src['container_type']} ${src['container_name']}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU in AAA-Users ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} ${onu_port}
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
# Verify subscriber access flows are added for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
@@ -305,7 +305,7 @@
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
# Remove Subscriber Access (To replicate ATT workflow)
- Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
END
#Enable the OLT back and check ONU, OLT status are back to "ACTIVE"