Running sanity test on BBSim two times to make sure repeated tests work
Change-Id: I38615fbfa82f1e5d3482271f6e7f3bf8266d5c85
diff --git a/tests/bbsim/Voltha_BBSimTests.robot b/tests/bbsim/Voltha_BBSimTests.robot
index a494b0f..95109a4 100644
--- a/tests/bbsim/Voltha_BBSimTests.robot
+++ b/tests/bbsim/Voltha_BBSimTests.robot
@@ -13,6 +13,7 @@
# limitations under the License.
*** Settings ***
+Documentation Run tests On BBSim
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
@@ -50,24 +51,19 @@
${container_log_dir} ${None}
# Number of times to perform ONU Igmp Join and Leave (valid only for TT)
${igmp_join_leave_count} 1
+# Number of times the Sanity test needs to be repeated as
+# we want to make sure you can disable/delete the device without needing to restart BBSim
+${iteration_count} 2
*** Test Cases ***
Test Perform BBSim Sanity
[Documentation] Validates the BBSim Functionality for ATT, DT and TT workflows
... Also Restart Auth (ATT), Restart Dhcp (ATT and TT), Igmp Join and Leave (TT)
- ... NOTE: Currently works only for single ONU in case of ATT
[Tags] bbsimSanity
- [Setup] Run Keywords Start Logging BBSimSanity
- ... AND Setup
- FOR ${J} IN RANGE 0 ${num_olts}
- ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
- ${onu_count}= Set Variable ${list_olts}[${J}][onucount]
- ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
- ... ${olt_serial_number}
- ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
- ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
- Perform BBSim Sanity Test Per OLT ${bbsim_pod} ${of_id} ${olt_serial_number} ${onu_count}
+ [Setup] Run Keyword Start Logging BBSimSanity
+ FOR ${I} IN RANGE 0 ${iteration_count}
+ Perform BBSim Sanity Test
END
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging BBSimSanity
@@ -93,6 +89,21 @@
... Verify ONU in Groups ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id} ${onu_port} False
END
+Perform BBSim Sanity Test
+ [Documentation] Runs the sanity test on multiple OLTs
+
+ Run Keyword Setup
+ FOR ${J} IN RANGE 0 ${num_olts}
+ ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
+ ${onu_count}= Set Variable ${list_olts}[${J}][onucount]
+ ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
+ ... ${olt_serial_number}
+ ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
+ ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
+ Perform BBSim Sanity Test Per OLT ${bbsim_pod} ${of_id} ${olt_serial_number} ${onu_count}
+ END
+ Run Keyword Delete All Devices and Verify
+
Perform BBSim Sanity Test Per OLT
[Documentation] Validates the BBSim Functionality for ATT, DT and TT workflows
... Also Restart Auth (ATT), Restart Dhcp (ATT and TT), Igmp Join and Leave (TT)
@@ -158,5 +169,4 @@
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
- Run Keyword If ${teardown_device} Delete All Devices and Verify
Close All ONOS SSH Connections