[VOL-3612] OpenOnu-Go-Adapter: Extend Flow Test for OpenOnu-Go
Change-Id: I1263602daca9fa5c3c14355450ce0db2237ce390
diff --git a/tests/openonu-go-adapter/Voltha_ONUStateTests.robot b/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
index c772a00..ee16b80 100755
--- a/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
@@ -296,7 +296,9 @@
Wait for Ports in ONOS ${onos_ssh_connection} ${num_all_onus} BBSM
Do Onu Flow Check
- [Documentation] This keyword iterate all OLTs and performs Do Onu Flow Check Per OLT
+ [Documentation] This keyword iterate all OLTs and performs Do Onu Flow Checks Per OLT
+ # Check and store vlan rules
+ ${firstvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${onu_count}= Set Variable ${list_olts}[${J}][onucount]
@@ -307,11 +309,36 @@
... Get NNI Port in ONOS ${of_id}
Set Global Variable ${nni_port}
# Verify Default Meter in ONOS (valid only for ATT)
- Do Onu Flow Check Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count}
+ Do Onu Subscriber Add And Flow Check Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count}
END
+ #log flows for verification
+ ${flowsresult}= Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT} flows -s
+ log ${flowsresult}
+ #check for previous state is kept (normally omci-flows-pushed)
+ Sleep 10s
+ Run Keyword And Continue On Failure Do Current State Test All Onus ${state2test}
+ ${secondvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd nbofcookieslice=3
+ ... prevvlanrules=${firstvlanrules}
+ FOR ${J} IN RANGE 0 ${num_olts}
+ ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
+ ${onu_count}= Set Variable ${list_olts}[${J}][onucount]
+ ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
+ ... ${olt_serial_number}
+ Set Global Variable ${of_id}
+ ${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get NNI Port in ONOS ${of_id}
+ Set Global Variable ${nni_port}
+ # Verify Default Meter in ONOS (valid only for ATT)
+ Do Onu Subscriber Remove Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count}
+ END
+ #check for previous state is kept (normally omci-flows-pushed)
+ Sleep 10s
+ Run Keyword And Continue On Failure Do Current State Test All Onus ${state2test}
+ Run Keyword And Continue On Failure Validate Vlan Rules In Etcd prevvlanrules=${firstvlanrules}
+ ... setvidequal=True
-Do Onu Flow Check Per OLT
- [Documentation] Check per OLT that all ONU flows show up in ONOS and Voltha
+Do Onu Subscriber Add And Flow Check Per OLT
+ [Documentation] Add Subscriber per OLT and checks all ONU flows show up in ONOS and Voltha
[Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
@@ -328,8 +355,21 @@
... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
END
- #check for previous state is kept (normally omci-flows-pushed)
- Do Current State Test All Onus ${state2test}
+
+Do Onu Subscriber Remove Per OLT
+ [Documentation] Removes per OLT subscribers in ONOS and Voltha
+ [Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus}
+ FOR ${I} IN RANGE 0 ${num_all_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
+ ${onu_device_id}= Get Device ID From SN ${src['onu']}
+ ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get ONU Port in ONOS ${src['onu']} ${of_id}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
+ ... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-remove-subscriber-access ${of_id} ${onu_port}
+ END
Set Tech Profile