TestSuite changes for VGC

Change-Id: I180edb346c309827d125e371083f9accc2014f0e
diff --git a/tests/dt-workflow/Voltha_DT_FTTB_Tests_VGC.robot b/tests/dt-workflow/Voltha_DT_FTTB_Tests_VGC.robot
new file mode 100644
index 0000000..63c89fe
--- /dev/null
+++ b/tests/dt-workflow/Voltha_DT_FTTB_Tests_VGC.robot
@@ -0,0 +1,86 @@
+# Copyright 2022 - present Open Networking Foundation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+# FIXME Can we use the same test against BBSim and Hardware?
+
+*** Settings ***
+Documentation     Test various DT FTTB end-to-end scenarios
+Suite Setup       Setup Suite
+Test Setup        Setup
+Test Teardown     Teardown
+Suite Teardown    Teardown Suite
+Library           Collections
+Library           String
+Library           OperatingSystem
+Library           XML
+Library           RequestsLibrary
+Library           ../../libraries/DependencyLibrary.py
+Resource          ../../libraries/vgc.robot
+Resource          ../../libraries/voltctl.robot
+Resource          ../../libraries/voltha.robot
+Resource          ../../libraries/utils_vgc.robot
+Resource          ../../libraries/k8s.robot
+Resource          ../../variables/variables.robot
+Resource          ../../libraries/power_switch.robot
+
+
+*** Variables ***
+${POD_NAME}       flex-ocp-cord
+${KUBERNETES_CONF}    ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_CONFIGS_DIR}    ~/pod-configs/kubernetes-configs
+#${KUBERNETES_CONFIGS_DIR}    ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_YAML}    ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
+${HELM_CHARTS_DIR}    ~/helm-charts
+${VOLTHA_POD_NUM}    8
+${NAMESPACE}      voltha
+${INFRA_NAMESPACE}      default
+${timeout}        60s
+${of_id}          0
+${logical_id}     0
+${uprate}         0
+${dnrate}         0
+${has_dataplane}    True
+${teardown_device}    True
+${scripts}        ../../scripts
+
+# Per-test logging on failure is turned off by default; set this variable to enable
+${container_log_dir}    ${None}
+
+# logging flag to enable Collect Logs, can be passed via the command line too
+# example: -v logging:False
+${logging}    True
+
+*** Test Cases ***
+Sanity E2E Test for OLT/ONU on POD for DT FTTB
+    [Documentation]    Validates E2E Ping Connectivity and object states for the given scenario:
+    ...    Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used
+    ...    Traffic sent with same vlan from different RGs,
+    ...    should reach the NNI port on the OLT with the expected double tagged vlan ids
+    ...    Inner vlans from the RG should not change
+    [Tags]    sanityDtFttb
+    [Setup]    Start Logging    SanityTestDtFttb
+    [Teardown]    Run Keywords    Run Keyword If    ${logging}    Collect Logs
+    ...           AND             Stop Logging    SanityTestDtFttb
+    Setup
+    Run Keyword If    ${has_dataplane}    Clean Up Linux
+    Perform Sanity Test DT FTTB
+
+*** Keywords ***
+Setup Suite
+    [Documentation]    Set up the test suite
+    Common Test Suite Setup
+    #Restore all ONUs
+    #Run Keyword If    ${has_dataplane}    RestoreONUs    ${num_all_onus}
+    #power_switch.robot needs it to support different vendor's power switch
+    ${switch_type}=    Get Variable Value    ${web_power_switch.type}
+    Run Keyword If  "${switch_type}"!=""    Set Global Variable    ${powerswitch_type}    ${switch_type}