[VOL-3243] Updates to ONU Port check keywords in onos libraries/tests
Change-Id: I89d8ea4efbabf2d2624998076bed68d10e4bdad1
diff --git a/tests/dt-workflow/Voltha_DT_FailureScenarios.robot b/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
index 585030e..9ceb958 100644
--- a/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
+++ b/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
@@ -98,7 +98,7 @@
Sleep 60s
# Check ONU port is Enabled in ONOS
Run Keyword And Continue On Failure Wait Until Keyword Succeeds 120s 2s
- ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
@@ -299,7 +299,7 @@
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
# Check ONU port is Disabled in ONOS
Run Keyword And Continue On Failure Wait Until Keyword Succeeds 120s 2s
- ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
# Verify subscriber access flows are added for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added For ONU DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
@@ -457,7 +457,7 @@
Sleep 40s
# Check ONU port is Enabled in ONOS
Run Keyword And Continue On Failure Wait Until Keyword Succeeds 120s 2s
- ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
diff --git a/tests/dt-workflow/Voltha_DT_PODTests.robot b/tests/dt-workflow/Voltha_DT_PODTests.robot
index 0c33c73..304ebac 100644
--- a/tests/dt-workflow/Voltha_DT_PODTests.robot
+++ b/tests/dt-workflow/Voltha_DT_PODTests.robot
@@ -179,7 +179,7 @@
... Validate Device DISABLED UNKNOWN
... REACHABLE ${src['onu']} onu=True onu_reason=omci-admin-lock
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
- ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
@@ -191,7 +191,7 @@
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=onu-reenabled
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
- ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
@@ -267,7 +267,7 @@
${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
- ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']}
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}