[VOL-3243] Updates to ONU Port check keywords in onos libraries/tests

Change-Id: I89d8ea4efbabf2d2624998076bed68d10e4bdad1
diff --git a/tests/functional/Voltha_FailureScenarios.robot b/tests/functional/Voltha_FailureScenarios.robot
index 350921c..6193a61 100644
--- a/tests/functional/Voltha_FailureScenarios.robot
+++ b/tests/functional/Voltha_FailureScenarios.robot
@@ -91,7 +91,7 @@
         Enable Switch Outlet    ${src['power_switch_port']}
         # Check ONU port is Enabled in ONOS
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds   120s   2s
-        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
+        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${src['onu']}
         # Verify EAPOL flows are added for the ONU port
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds    ${timeout}    2s
         ...    Verify Eapol Flows Added For ONU    ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
@@ -350,7 +350,7 @@
         ...    ${src['onu']}    onu=True    onu_reason=omci-flows-pushed
         # Check ONU port is Disabled in ONOS
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds   120s   2s
-        ...    Verify ONU Port Is Disabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
+        ...    Verify ONU Port Is Disabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${src['onu']}
         # Verify EAPOL flows are present for the ONU port
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds    ${timeout}    2s
         ...    Verify Eapol Flows Added For ONU    ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
@@ -401,7 +401,7 @@
         ${onu_port}=    Wait Until Keyword Succeeds    ${timeout}    2s    Get ONU Port in ONOS    ${src['onu']}
         ...    ${of_id}
         Run Keyword And Continue On Failure    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}
-        ...    ${onu_port}
+        ...    ${src['onu']}
         ${output}=    Run Keyword If    ${has_dataplane}    Login And Run Command On Remote System
         ...    wpa_cli status | grep SUCCESS    ${src['ip']}    ${src['user']}    ${src['pass']}
         ...    ${src['container_type']}    ${src['container_name']}
@@ -424,7 +424,7 @@
         ...    Get ONU Port in ONOS    ${src['onu']}    ${of_id}
         # Check ONU port is Enabled in ONOS
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds   120s   2s
-        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
+        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${src['onu']}
         # Verify EAPOL flows are added for the ONU port
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds    ${timeout}    2s
         ...    Verify Eapol Flows Added For ONU    ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
@@ -570,7 +570,7 @@
         Sleep    40s
         # Check ONU port is Enabled in ONOS
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds   120s   2s
-        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}
+        ...    Verify ONU Port Is Enabled   ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${src['onu']}
         # Verify EAPOL flows are added for the ONU port
         Run Keyword And Continue On Failure    Wait Until Keyword Succeeds    ${timeout}    2s
         ...    Verify Eapol Flows Added For ONU    ${ONOS_SSH_IP}    ${ONOS_SSH_PORT}    ${onu_port}