[VOL-3013][VOL-3015] Update DT and ATT TCs to replicate desired workflow
Change-Id: I2d4a3501ac6008b076eaaddbd8c5e6384369ea4f
diff --git a/tests/functional/Voltha_FailureScenarios.robot b/tests/functional/Voltha_FailureScenarios.robot
index f91c8ff..3fd4249 100644
--- a/tests/functional/Voltha_FailureScenarios.robot
+++ b/tests/functional/Voltha_FailureScenarios.robot
@@ -83,6 +83,9 @@
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ # Remove Subscriber Access (To replicate ATT workflow)
+ Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
+ ... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Enable Switch Outlet ${src['power_switch_port']}
# Check ONU port is Enabled in ONOS
@@ -95,14 +98,33 @@
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ # Perform Authentication
+ ${wpa_log}= Run Keyword If ${has_dataplane} Catenate SEPARATOR=.
+ ... /tmp/wpa ${src['dp_iface_name']} log
+ Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate Authentication True
+ ... ${src['dp_iface_name']} wpa_supplicant.conf ${src['ip']} ${src['user']} ${src['pass']}
+ ... ${src['container_type']} ${src['container_name']} ${wpa_log}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
+ ... Verify ONU in AAA-Users ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
+ ... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify that no pending flows exist for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
# Verify subscriber access flows are added for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
- Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
- ... Wait Until Keyword Succeeds 60s 2s
- ... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
+ Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
+ ... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ ... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
+ ... ${dst['container_name']}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Validate Subscriber DHCP Allocation ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
Run Keyword And Ignore Error Collect Logs
END
# Deleting OLT after tests completes independently (as this test doesn't not run on each POD)