Adding logs to setup and teardown to better debug cleanup issues
Change-Id: I4972fd0057c125f63790a40aa7117db06912ed16
diff --git a/tests/openonu-go-adapter/Voltha_ONUFlowChecks.robot b/tests/openonu-go-adapter/Voltha_ONUFlowChecks.robot
index ad700d2..3858c75 100755
--- a/tests/openonu-go-adapter/Voltha_ONUFlowChecks.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUFlowChecks.robot
@@ -104,6 +104,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite inclusive enable device and sanity test of given workflow
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
Common Test Suite Setup
${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
Set Suite Variable ${techprofile}
@@ -118,11 +119,14 @@
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
+ Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
@@ -130,6 +134,8 @@
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix}
... without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Remove Tech Profile ${INFRA_NAMESPACE}
diff --git a/tests/openonu-go-adapter/Voltha_ONUNegativeStateTests.robot b/tests/openonu-go-adapter/Voltha_ONUNegativeStateTests.robot
index 07a44c9..512c498 100755
--- a/tests/openonu-go-adapter/Voltha_ONUNegativeStateTests.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUNegativeStateTests.robot
@@ -92,6 +92,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... techprofile:${techprofile},
@@ -109,11 +110,14 @@
Delete MIB Template Data ${INFRA_NAMESPACE}
# delete etcd onu data
Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
+ Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
@@ -121,5 +125,7 @@
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix}
... without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Remove Tech Profile ${INFRA_NAMESPACE}
diff --git a/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot b/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot
index e401f11..64b6312 100755
--- a/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUOmciGetTest.robot
@@ -78,6 +78,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite inclusive enable device and sanity test of given workflow
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
Common Test Suite Setup
${switch_type}= Get Variable Value ${web_power_switch.type}
Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type}
@@ -86,3 +87,5 @@
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
diff --git a/tests/openonu-go-adapter/Voltha_ONUReconcileTests.robot b/tests/openonu-go-adapter/Voltha_ONUReconcileTests.robot
index 11bfdb1..5a22947 100755
--- a/tests/openonu-go-adapter/Voltha_ONUReconcileTests.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUReconcileTests.robot
@@ -170,6 +170,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
@@ -181,12 +182,15 @@
Delete MIB Template Data ${INFRA_NAMESPACE}
# delete etcd onu data
Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
+ Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
@@ -195,6 +199,8 @@
Run Keyword Unless ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s
... Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix} without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Setup Test
diff --git a/tests/openonu-go-adapter/Voltha_ONUStateTests.robot b/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
index 8001c96..f9d4a21 100755
--- a/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUStateTests.robot
@@ -183,6 +183,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... state2test:${state2test}, testmode:${testmode}, techprofile:${techprofile},
@@ -216,11 +217,14 @@
Delete MIB Template Data ${INFRA_NAMESPACE}
# delete etcd onu data
Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
+ Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
@@ -228,6 +232,8 @@
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix}
... without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Remove Tech Profile ${INFRA_NAMESPACE}
diff --git a/tests/openonu-go-adapter/Voltha_ONUTemplateTests.robot b/tests/openonu-go-adapter/Voltha_ONUTemplateTests.robot
index db6f8a4..ca476db 100755
--- a/tests/openonu-go-adapter/Voltha_ONUTemplateTests.robot
+++ b/tests/openonu-go-adapter/Voltha_ONUTemplateTests.robot
@@ -85,6 +85,7 @@
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
+ Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
@@ -92,11 +93,14 @@
Common Test Suite Setup
# delete etcd MIB Template Data
Delete MIB Template Data ${INFRA_NAMESPACE}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
+ Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
@@ -104,6 +108,8 @@
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM
# delete etcd MIB Template Data (for repeating test)
Delete MIB Template Data ${INFRA_NAMESPACE}
+ Run Keyword If ${logging} Collect Logs
+ Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Perform ONU MIB Template Data Test