| # Copyright 2017 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # FIXME Can we use the same test against BBSim and Hardware? |
| |
| *** Settings *** |
| Documentation Test various end-to-end scenarios |
| Suite Setup Setup Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Suite Teardown Teardown Suite |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${POD_NAME} flex-ocp-cord |
| ${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs |
| #${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml |
| ${HELM_CHARTS_DIR} ~/helm-charts |
| ${VOLTHA_POD_NUM} 8 |
| ${NAMESPACE} voltha |
| # For below variable value, using deployment name as using grep for |
| # parsing radius pod name, we can also use full radius pod name |
| ${RESTART_POD_NAME} radius |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${teardown_device} False |
| ${scripts} ../../scripts |
| |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| |
| *** Test Cases *** |
| Sanity E2E Test for OLT/ONU on POD for DT |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used |
| ... Traffic sent with same vlan from different RGs, |
| ... should reach the NNI port on the OLT with the expected double tagged vlan ids |
| ... Inner vlans from the RG should not change |
| [Tags] sanityDt |
| [Setup] Run Keywords Announce Message START TEST SanityTestDt |
| ... AND Start Logging SanityTestDt |
| ... AND Setup |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging SanityTestDt |
| ... AND Announce Message END TEST SanityTestDt |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test DT |
| |
| Test Subscriber Delete and Add for DT |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed) |
| ... Delete a subscriber and validate that the pings do not succeed and state is purged |
| ... Disable and Enable the ONU (This is to replicate the existing DT behaviour) |
| ... Re-add the subscriber, and validate that the flows are present and pings are successful |
| [Tags] functionalDt SubAddDeleteDt |
| [Setup] Run Keywords Announce Message START TEST SubAddDeleteDt |
| ... AND Start Logging SubAddDeleteDt |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging SubAddDeleteDt |
| ... AND Announce Message END TEST SubAddDeleteDt |
| FOR ${I} IN RANGE 0 ${num_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']} |
| ... ${of_id} |
| # Remove Subscriber Access |
| Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP} |
| ... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port} |
| Sleep 10s |
| # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652) |
| Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure |
| ... Wait Until Keyword Succeeds 60s 2s |
| ... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']} |
| ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']} |
| # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream) |
| ${onos_flows_count}= Evaluate 4 * ( ${num_onus} - 1 ) |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| ... ${onos_flows_count} |
| # Verify VOLTHA flows for OLT equals twice the number of ONUS (minus ONU under test) + 1 for LLDP |
| ${olt_flows}= Evaluate 2 * ( ${num_onus} - 1 ) + 1 |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows} |
| # Verify VOLTHA flows for ONU under test is Zero |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate Device Flows |
| ... ${onu_device_id} 0 |
| # Disable and Re-Enable the ONU (To replicate DT current workflow) |
| # TODO: Delete and Auto-Discovery Add of ONU (not yet supported) |
| Disable Device ${onu_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate Device DISABLED UNKNOWN |
| ... REACHABLE ${src['onu']} |
| Enable Device ${onu_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate Device ENABLED ACTIVE |
| ... REACHABLE ${src['onu']} |
| # Add Subscriber Access |
| Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP} |
| ... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port} |
| Sleep 10s |
| # Verify subscriber access flows are added for the ONU port |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Verify Subscriber Access Flows Added For ONU DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port} |
| ... ${nni_port} ${src['s_tag']} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate Device ENABLED ACTIVE |
| ... REACHABLE ${src['onu']} onu=True onu_reason=omci-flows-pushed |
| # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652) |
| Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure |
| ... Wait Until Keyword Succeeds 60s 2s |
| ... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']} |
| ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']} |
| Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id} |
| Run Keyword and Ignore Error Collect Logs |
| END |
| # Verify ONOS Flows |
| # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream) |
| ${onos_flows_count}= Evaluate 4 * ${num_onus} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onos_flows_count} |
| # Verify VOLTHA Flows |
| # Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP |
| ${olt_flows}= Evaluate 2 * ${num_onus} + 1 |
| # Number of per ONU Flows equals 2 (one each for downstream and upstream) |
| ${onu_flows}= Set Variable 2 |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows} |
| ${List_ONU_Serial} Create List |
| Set Suite Variable ${List_ONU_Serial} |
| Build ONU SN List ${List_ONU_Serial} |
| Log ${List_ONU_Serial} |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONU Flows |
| ... ${List_ONU_Serial} ${onu_flows} |
| |
| Test Disable and Enable ONU for DT |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed) |
| ... Perform disable on the ONUs and validate that the pings do not succeed |
| ... Perform enable on the ONUs and validate that the pings are successful |
| [Tags] functionalDt DisableEnableONUDt |
| [Setup] Run Keywords Announce Message START TEST DisableEnableONUDt |
| ... AND Start Logging DisableEnableONUDt |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging DisableEnableONUDt |
| ... AND Announce Message END TEST DisableEnableONUDt |
| FOR ${I} IN RANGE 0 ${num_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']} |
| ... ${of_id} |
| Disable Device ${onu_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate Device DISABLED UNKNOWN |
| ... REACHABLE ${src['onu']} onu=True onu_reason=omci-admin-lock |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port} |
| # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652) |
| Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure |
| ... Wait Until Keyword Succeeds 60s 2s |
| ... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']} |
| ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']} |
| Sleep 5s |
| Enable Device ${onu_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate Device ENABLED ACTIVE |
| ... REACHABLE ${src['onu']} onu=True onu_reason=onu-reenabled |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port} |
| # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652) |
| Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure |
| ... Wait Until Keyword Succeeds 60s 2s |
| ... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']} |
| ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']} |
| Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id} |
| Run Keyword and Ignore Error Collect Logs |
| END |
| |
| Test Disable and Delete OLT for DT |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed) |
| ... Perform disable on the OLT and validate ONUs state and that the pings do not succeed |
| ... Perform delete on the OLT, Re-do Setup (Recreate the OLT) and Perform Sanity Test DT |
| [Tags] functionalDt DisableDeleteOLTDt |
| [Setup] Run Keywords Announce Message START TEST DisableDeleteOLTDt |
| ... AND Start Logging DisableDeleteOLTDt |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging DisableDeleteOLTDt |
| ... AND Announce Message END TEST DisableDeleteOLTDt |
| # Disable and Validate OLT Device |
| Disable Device ${olt_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate OLT Device DISABLED UNKNOWN REACHABLE |
| ... ${olt_serial_number} |
| # Validate ONUs |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONUs After OLT Disable |
| # Verify ONOS Flows |
| # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream) |
| ${onos_flows_count}= Evaluate 4 * ${num_onus} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onos_flows_count} |
| # Verify VOLTHA Flows |
| # Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP |
| ${olt_flows}= Evaluate 2 * ${num_onus} + 1 |
| # Number of per ONU Flows equals 2 (one each for downstream and upstream) |
| ${onu_flows}= Set Variable 2 |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows} |
| ${List_ONU_Serial} Create List |
| Set Suite Variable ${List_ONU_Serial} |
| Build ONU SN List ${List_ONU_Serial} |
| Log ${List_ONU_Serial} |
| Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONU Flows |
| ... ${List_ONU_Serial} ${onu_flows} |
| # Delete OLT and Validate Empty Device List |
| Delete Device ${olt_device_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Test Empty Device List |
| Run Keyword and Ignore Error Collect Logs |
| # Re-do Setup (Recreate the OLT) and Perform Sanity Test DT |
| Run Keyword Setup |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test DT |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Common Test Suite Setup |
| |
| Clear All Devices Then Create New Device |
| [Documentation] Remove any devices from VOLTHA and ONOS |
| # Remove all devices from voltha and nos |
| Delete All Devices and Verify |
| # Execute normal test Setup Keyword |
| Setup |
| |