[VOL-4647] Added DT FTTB Sanity Test
Change-Id: I499705bd744204a67b709234f424fcdc3c17d881
diff --git a/tests/dt-workflow/Voltha_DT_FTTB_Tests.robot b/tests/dt-workflow/Voltha_DT_FTTB_Tests.robot
new file mode 100644
index 0000000..226988e
--- /dev/null
+++ b/tests/dt-workflow/Voltha_DT_FTTB_Tests.robot
@@ -0,0 +1,85 @@
+# Copyright 2022 - present Open Networking Foundation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+# FIXME Can we use the same test against BBSim and Hardware?
+
+*** Settings ***
+Documentation Test various DT FTTB end-to-end scenarios
+Suite Setup Setup Suite
+Test Setup Setup
+Test Teardown Teardown
+Suite Teardown Teardown Suite
+Library Collections
+Library String
+Library OperatingSystem
+Library XML
+Library RequestsLibrary
+Library ../../libraries/DependencyLibrary.py
+Resource ../../libraries/onos.robot
+Resource ../../libraries/voltctl.robot
+Resource ../../libraries/voltha.robot
+Resource ../../libraries/utils.robot
+Resource ../../libraries/k8s.robot
+Resource ../../variables/variables.robot
+Resource ../../libraries/power_switch.robot
+
+*** Variables ***
+${POD_NAME} flex-ocp-cord
+${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
+#${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
+${HELM_CHARTS_DIR} ~/helm-charts
+${VOLTHA_POD_NUM} 8
+${NAMESPACE} voltha
+${INFRA_NAMESPACE} default
+${timeout} 60s
+${of_id} 0
+${logical_id} 0
+${uprate} 0
+${dnrate} 0
+${has_dataplane} True
+${teardown_device} True
+${scripts} ../../scripts
+
+# Per-test logging on failure is turned off by default; set this variable to enable
+${container_log_dir} ${None}
+
+# logging flag to enable Collect Logs, can be passed via the command line too
+# example: -v logging:False
+${logging} True
+
+*** Test Cases ***
+Sanity E2E Test for OLT/ONU on POD for DT FTTB
+ [Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
+ ... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used
+ ... Traffic sent with same vlan from different RGs,
+ ... should reach the NNI port on the OLT with the expected double tagged vlan ids
+ ... Inner vlans from the RG should not change
+ [Tags] sanityDtFttb
+ [Setup] Start Logging SanityTestDtFttb
+ [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
+ ... AND Stop Logging SanityTestDtFttb
+ Setup
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ Perform Sanity Test DT FTTB
+
+*** Keywords ***
+Setup Suite
+ [Documentation] Set up the test suite
+ Common Test Suite Setup
+ #Restore all ONUs
+ #Run Keyword If ${has_dataplane} RestoreONUs ${num_all_onus}
+ #power_switch.robot needs it to support different vendor's power switch
+ ${switch_type}= Get Variable Value ${web_power_switch.type}
+ Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type}