+Test ONU Delete and Auto-Discovery
+ [Documentation] Tests the voltctl delete and Auto-Discovery of the ONU
+ [Tags] functional VOL-3098 ONUAutoDiscovery notready
+ [Setup] Run Keywords Start Logging ONUAutoDiscovery
+ ... AND Setup
+ [Teardown] Run Keywords Collect Logs
+ ... AND Delete All Devices and Verify
+ ... AND Run Keyword If ${logging} Collect Logs
+ ... AND Stop Logging ONUAutoDiscovery
+ # Performing Sanity Test to make sure subscribers are all AUTH+DHCP and pingable
+ Run Keyword If ${has_dataplane} Clean Up Linux
+ Perform Sanity Test
+ FOR ${I} IN RANGE 0 ${num_all_onus}
+ ${src}= Set Variable ${hosts.src[${I}]}
+ ${dst}= Set Variable ${hosts.dst[${I}]}
+ ${onu_device_id}= Get Device ID From SN ${src['onu']}
+ ${of_id}= Get ofID From OLT List ${src['olt']}
+ ${nni_port}= Wait Until Keyword Succeeds ${timeout} 2s Get NNI Port in ONOS ${of_id}
+ ${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get ONU Port in ONOS ${src['onu']} ${of_id}
+ # Remove Subscriber Access (To replicate ATT workflow)
+ Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-remove-subscriber-access ${of_id} ${onu_port}
+ # Additional sleep to let subscriber delete process
+ Sleep 10s
+ # Delete ONU and Verify Ping Fails
+ Delete Device ${onu_device_id}
+ Run Keyword If ${has_dataplane} Verify ping is successful except for given device
+ ... ${num_all_onus} ${src['onu']}
+ # Verify that no pending flows exist for the ONU port
+ Wait Until Keyword Succeeds ${timeout} 2s
+ ... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ # ONU Auto-Discovery
+ ${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get ONU Port in ONOS ${src['onu']} ${of_id} ${src['uni_id']}
+ # Check ONU port is Enabled in ONOS
+ Wait Until Keyword Succeeds ${timeout} 2s
+ ... Verify UNI Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']} ${src['uni_id']}
+ ${onu_device_id}= Get Device ID From SN ${src['onu']}
+ Run Keyword If ${has_dataplane} Clean Up Linux ${onu_device_id}
+ # Verify default EAPOL flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Verify Eapol Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id} ${onu_port}
+ # Verify ONU state in voltha
+ Wait Until Keyword Succeeds ${timeout} 5s Validate Device ENABLED ACTIVE REACHABLE
+ ... ${src['onu']} onu=True onu_reason=omci-flows-pushed
+ # Perform Authentication
+ ${wpa_log}= Run Keyword If ${has_dataplane} Catenate SEPARATOR=.
+ ... /tmp/wpa ${src['dp_iface_name']} log
+ Run Keyword If ${has_dataplane} Validate Authentication True
+ ... ${src['dp_iface_name']} wpa_supplicant.conf ${src['ip']} ${src['user']} ${src['pass']}
+ ... ${src['container_type']} ${src['container_name']} ${wpa_log}
+ Wait Until Keyword Succeeds ${timeout} 2
+ ... Verify ONU in AAA-Users ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify that no pending flows exist for the ONU port
+ Wait Until Keyword Succeeds ${timeout} 2s
+ ... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
+ # Verify subscriber EAPOL flow is installed
+ Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Eapol Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
+ ... ${onu_port} ${src['c_tag']}
+ # Verify Meters in ONOS
+ Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Meters in ONOS ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id} ${onu_port}
+ Run Keyword If ${has_dataplane} Validate DHCP and Ping True
+ ... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
+ ... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ ... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
+ ... ${dst['container_name']}
+ Wait Until Keyword Succeeds ${timeout} 2s
+ ... Validate Subscriber DHCP Allocation ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ END
+
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite