blob: 35d847836f9f61a5340cc4abdb6d759c014f8731 [file] [log] [blame]
# Copyright 2021 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# FIXME Can we use the same test against BBSim and Hardware?
*** Settings ***
Documentation Test of open ONU go adapter OMCI Get
Suite Setup Setup Suite
Test Setup Setup
Test Teardown Teardown
Suite Teardown Teardown Suite
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../variables/variables.robot
Resource ../../libraries/power_switch.robot
*** Variables ***
${namespace} voltha
${INFRA_NAMESPACE} default
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# determines the environment workflow: DT, TT or ATT (default)
# example: -v workflow:DT
${workflow} ATT
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
${data_dir} ../data
*** Test Cases ***
ANI-G Test
[Documentation] Validates ANI-G output of ONU device(s):
[Tags] functionalOnuGo AniGTest
[Setup] Start Logging AniGTest
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${voltctl_commad} = Catenate SEPARATOR=
... voltctl device getextval onu_pon_optical_info ${onu_device_id}
${rc} ${output}= Run and Return Rc and Output ${voltctl_commad}
Should Be Equal As Integers ${rc} 0
Should Contain ${output} POWER_FEED_VOLTAGE__VOLTS:
Should Contain ${output} 3.26
Should Contain ${output} RECEIVED_OPTICAL_POWER__dBm:
Should Contain ${output} MEAN_OPTICAL_LAUNCH_POWER__dBm:
Should Contain ${output} LASER_BIAS_CURRENT__mA:
Should Contain ${output} TEMPERATURE__Celsius:
END
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging SanityTestOnuGo
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite inclusive enable device and sanity test of given workflow
Start Logging Setup or Teardown Setup-${SUITE NAME}
Common Test Suite Setup
${switch_type}= Get Variable Value ${web_power_switch.type}
Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type}
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Setup-${SUITE NAME}