Adding timeouts for inband tests
Change-Id: I21d2deb962fb85d64833163bb49e08c6a1214ae4
diff --git a/tests/dt-workflow/Voltha_DT_FailureScenarios.robot b/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
index 60c7fa7..8e496be 100644
--- a/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
+++ b/tests/dt-workflow/Voltha_DT_FailureScenarios.robot
@@ -103,7 +103,7 @@
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
# Verify ONU state in voltha
- Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 360s 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
# Verify subscriber access flows are added for the ONU port
@@ -228,7 +228,7 @@
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id}
# Bring up the device and verify it authenticates
- Wait Until Keyword Succeeds ${timeout} 5s Validate Device ENABLED ACTIVE REACHABLE
+ Wait Until Keyword Succeeds 360s 5s Validate Device ENABLED ACTIVE REACHABLE
... ${onu_device_id} onu=True onu_reason=omci-flows-pushed
END
# Scale down the open OLT adapter deployment to 0 PODs and once confirmed, scale it back to 1
@@ -294,7 +294,7 @@
${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
# Verify ONU state in voltha
- Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 360s 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
# Check ONU port is Disabled in ONOS
@@ -346,7 +346,7 @@
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id}
# Bring up the device and verify it authenticates
- Wait Until Keyword Succeeds ${timeout} 5s Validate Device ENABLED ACTIVE REACHABLE
+ Wait Until Keyword Succeeds 360s 5s Validate Device ENABLED ACTIVE REACHABLE
... ${onu_device_id} onu=True onu_reason=initial-mib-downloaded
END
@@ -418,7 +418,7 @@
# Waiting extra time for the ONUs to come up
Sleep 60s
# Check OLT states
- Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
+ Wait Until Keyword Succeeds 360s 5s Validate OLT Device ENABLED ACTIVE REACHABLE
... ${olt_serial_number}
Run Keyword And Ignore Error Collect Logs
#Check after reboot that ONUs are active, DHCP and pingable
@@ -462,7 +462,7 @@
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
# Verify ONU state in voltha
- Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds 360s 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
# Verify subscriber access flows are added for the ONU port