[VOL-2473]Sanity Test keyword
Change-Id: I3a9e9e79784eccb9519c89c82e7f64a12ee49532
diff --git a/tests/functional/Voltha_ErrorScenarios.robot b/tests/functional/Voltha_ErrorScenarios.robot
new file mode 100644
index 0000000..76908b5
--- /dev/null
+++ b/tests/functional/Voltha_ErrorScenarios.robot
@@ -0,0 +1,78 @@
+# Copyright 2017 - present Open Networking Foundation
+#
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+# FIXME Can we use the same test against BBSim and Hardware?
+
+*** Settings ***
+Documentation Test various end-to-end scenarios
+Suite Setup Common Test Suite Setup
+Test Setup Setup
+Test Teardown Teardown
+#Suite Teardown Teardown Suite
+Library Collections
+Library String
+Library OperatingSystem
+Library XML
+Library RequestsLibrary
+Library ../../libraries/DependencyLibrary.py
+Resource ../../libraries/onos.robot
+Resource ../../libraries/voltctl.robot
+Resource ../../libraries/voltha.robot
+Resource ../../libraries/utils.robot
+Resource ../../libraries/k8s.robot
+Resource ../../variables/variables.robot
+
+*** Variables ***
+${POD_NAME} flex-ocp-cord
+${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
+#${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
+${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
+${HELM_CHARTS_DIR} ~/helm-charts
+${VOLTHA_POD_NUM} 8
+${NAMESPACE} voltha
+# For below variable value, using deployment name as using grep for
+# parsing radius pod name, we can also use full radius pod name
+${RESTART_POD_NAME} radius
+${timeout} 60s
+${of_id} 0
+${logical_id} 0
+${has_dataplane} False
+${external_libs} True
+${teardown_device} False
+${scripts} ../../scripts
+
+*** Test Cases ***
+Adding the same OLT before and after enabling the device
+ [Documentation] Create OLT, Create the same OLT again and Check for the Error message
+ [Tags] VOL-2405 VOL-2406 AddSameOLT notready
+ [Setup] None
+ [Teardown] None
+ ${olt_device_id}= Create Device ${olt_ip} ${OLT_PORT}
+ Set Suite Variable ${olt_device_id}
+ Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN
+ ... ${EMPTY} ${olt_device_id}
+ ${rc} ${output}= Run and Return Rc and Output
+ ... ${VOLTCTL_CONFIG}; voltctl device create -t openolt -H ${olt_ip}:${OLT_PORT}
+ Should Not Be Equal As Integers ${rc} 0
+ Should Contain ${output} Device is already pre-provisioned
+ #Enable the created OLT device
+ Enable Device ${olt_device_id}
+ Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
+ ... ${olt_serial_number}
+ ${rc} ${output}= Run and Return Rc and Output
+ ... ${VOLTCTL_CONFIG}; voltctl device create -t openolt -H ${olt_ip}:${OLT_PORT}
+ Should Not Be Equal As Integers ${rc} 0
+ Log ${output}
+ Should Contain ${output} Device is already pre-provisioned
+ Log "This OLT is added already and enabled"