[VOL-2824] DT Workflow: Verify Subscriber Access Flows Added For ONUs
Change-Id: Id70a9bb8769344f80da6007417f331d0eda4dba6
diff --git a/libraries/onos.robot b/libraries/onos.robot
index 921ca50..dc30c9a 100644
--- a/libraries/onos.robot
+++ b/libraries/onos.robot
@@ -65,6 +65,27 @@
Should Be True ${matched} No match for ${onu_serial_number} found
[Return] ${onu_port}
+Get NNI Port in ONOS
+ [Arguments] ${olt_of_id}
+ [Documentation] Retrieves NNI port for the OLT in ONOS
+ ${resp}= Get Request ONOS onos/v1/devices/${olt_of_id}/ports
+ ${jsondata}= To Json ${resp.content}
+ Should Not Be Empty ${jsondata['ports']}
+ ${length}= Get Length ${jsondata['ports']}
+ @{ports}= Create List
+ ${matched}= Set Variable False
+ FOR ${INDEX} IN RANGE 0 ${length}
+ ${value}= Get From List ${jsondata['ports']} ${INDEX}
+ ${annotations}= Get From Dictionary ${value} annotations
+ ${nni_port}= Get From Dictionary ${value} port
+ ${nniPortName}= Catenate SEPARATOR= nni- ${nni_port}
+ ${portName}= Get From Dictionary ${annotations} portName
+ ${matched}= Set Variable If '${portName}' == '${nniPortName}' True False
+ Exit For Loop If ${matched}
+ END
+ Should Be True ${matched} No match for NNI found for ${olt_of_id}
+ [Return] ${nni_port}
+
Get FabricSwitch in ONOS
[Documentation] Returns of_id of the Fabric Switch in ONOS
${resp}= Get Request ONOS onos/v1/devices
@@ -82,6 +103,39 @@
Should Be True ${matched} No fabric switch found
[Return] ${of_id}
+Verify Subscriber Access Flows Added for ONU DT
+ [Arguments] ${ip} ${port} ${onu_port} ${nni_port} ${s_tag}
+ [Documentation] Verifies if the Subscriber Access Flows are added in ONOS for the ONU
+ # Verify upstream table=0 flow
+ ${upstream_flow_0_added}= Execute ONOS CLI Command ${ip} ${port}
+ ... flows -s -f ADDED | grep IN_PORT:${onu_port} | grep VLAN_VID:Any | grep transition=TABLE:1
+ Should Not Be Empty ${upstream_flow_0_added}
+ # Verify upstream table=1 flow
+ ${flow_vlan_push_cmd}= Catenate SEPARATOR=
+ ... flows -s -f ADDED | grep IN_PORT:${onu_port} | grep VLAN_VID:Any |
+ ... grep VLAN_PUSH | grep VLAN_ID:${s_tag} | grep OUTPUT:${nni_port}
+ ${upstream_flow_1_added}= Execute ONOS CLI Command ${ip} ${port}
+ ... ${flow_vlan_push_cmd}
+ Should Not Be Empty ${upstream_flow_1_added}
+ # Verify downstream table=0 flow
+ ${flow_vlan_pop_cmd}= Catenate SEPARATOR=
+ ... flows -s -f ADDED | grep IN_PORT:${nni_port} | grep VLAN_VID:${s_tag} |
+ ... grep VLAN_POP | grep transition=TABLE:1
+ ${downstream_flow_0_added}= Execute ONOS CLI Command ${ip} ${port}
+ ... ${flow_vlan_pop_cmd}
+ Should Not Be Empty ${downstream_flow_0_added}
+ # Verify downstream table=1 flow
+ ${downstream_flow_1_added}= Execute ONOS CLI Command ${ip} ${port}
+ ... flows -s -f ADDED | grep IN_PORT:${nni_port} | grep VLAN_VID:Any | grep OUTPUT:${onu_port}
+ Should Not Be Empty ${downstream_flow_1_added}
+
+Verify Subscriber Access Flows Added Count DT
+ [Arguments] ${ip} ${port} ${expected_flows}
+ [Documentation] Matches for total number of subscriber access flows added for all onus
+ ${access_flows_added}= Execute ONOS CLI Command ${ip} ${port}
+ ... flows -s -f ADDED | grep -v deviceId | grep -v ETH_TYPE:lldp | wc -l
+ Should Be Equal As Integers ${access_flows_added} ${expected_flows}
+
Verify Eapol Flows Added
[Arguments] ${ip} ${port} ${expected_flows}
[Documentation] Matches for number of eapol flows based on number of onus
diff --git a/libraries/utils.robot b/libraries/utils.robot
index e2cb049..4b98f51 100644
--- a/libraries/utils.robot
+++ b/libraries/utils.robot
@@ -200,6 +200,9 @@
... and avoids duplication of code.
${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS ${olt_serial_number}
Set Global Variable ${of_id}
+ ${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
+ ... Get NNI Port in ONOS ${of_id}
+ Set Global Variable ${nni_port}
FOR ${I} IN RANGE 0 ${num_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
@@ -212,11 +215,15 @@
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
... Execute ONOS CLI Command ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... ${nni_port} ${src['s_tag']}
# Verify ONU state in voltha
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
... ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=omci-flows-pushed
- # TODO: Yet to Verify on the Physical POD
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure Validate DHCP and Ping True
... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
@@ -225,7 +232,12 @@
Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
Run Keyword and Ignore Error Collect Logs
END
- # Verify VOLTHA Flows (TODO: Add verification for ONOS Flows)
+ # Verify ONOS Flows
+ # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
+ ${onos_flows_count}= Evaluate 4 * ${num_onus}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onos_flows_count}
+ # Verify VOLTHA Flows
# Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP
${olt_flows}= Evaluate 2 * ${num_onus} + 1
# Number of per ONU Flows equals 2 (one each for downstream and upstream)
diff --git a/tests/data/bbsim-kind-dt.yaml b/tests/data/bbsim-kind-dt.yaml
index 71affaf..c301af8 100644
--- a/tests/data/bbsim-kind-dt.yaml
+++ b/tests/data/bbsim-kind-dt.yaml
@@ -34,7 +34,10 @@
hosts:
src:
- - onu: 'BBSM00000001'
+ -
+ onu: 'BBSM00000001'
+ c_tag: '4096'
+ s_tag: '900'
dst:
- ip: null
diff --git a/tests/dt-workflow/Voltha_DT_PODTests.robot b/tests/dt-workflow/Voltha_DT_PODTests.robot
index 2fd1549..54d4631 100644
--- a/tests/dt-workflow/Voltha_DT_PODTests.robot
+++ b/tests/dt-workflow/Voltha_DT_PODTests.robot
@@ -93,11 +93,16 @@
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Sleep 10s
- # TODO: Yet to Verify on the Physical POD
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
+ # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
+ ${onos_flows_count}= Evaluate 4 * ( ${num_onus} - 1 )
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
+ ... ${onos_flows_count}
# Verify VOLTHA flows for OLT equals twice the number of ONUS (minus ONU under test) + 1 for LLDP
${olt_flows}= Evaluate 2 * ( ${num_onus} - 1 ) + 1
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows}
@@ -118,10 +123,14 @@
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
Sleep 10s
+ # Verify subscriber access flows are added for the ONU port
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added For ONU DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
+ ... ${nni_port} ${src['s_tag']}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=omci-flows-pushed
- # TODO: Yet to Verify on the Physical POD
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
@@ -129,7 +138,12 @@
Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
Run Keyword and Ignore Error Collect Logs
END
- # Verify VOLTHA Flows (TODO: Add verification for ONOS Flows)
+ # Verify ONOS Flows
+ # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
+ ${onos_flows_count}= Evaluate 4 * ${num_onus}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onos_flows_count}
+ # Verify VOLTHA Flows
# Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP
${olt_flows}= Evaluate 2 * ${num_onus} + 1
# Number of per ONU Flows equals 2 (one each for downstream and upstream)
@@ -165,7 +179,7 @@
... REACHABLE ${src['onu']} onu=True onu_reason=omci-admin-lock
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
- # TODO: Yet to Verify on the Physical POD
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
@@ -177,7 +191,7 @@
... REACHABLE ${src['onu']} onu=True onu_reason=onu-reenabled
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
- # TODO: Yet to Verify on the Physical POD
+ # TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
@@ -204,7 +218,12 @@
... ${olt_serial_number}
# Validate ONUs
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONUs After OLT Disable
- # Verify VOLTHA Flows (TODO: Add verification for ONOS Flows)
+ # Verify ONOS Flows
+ # Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
+ ${onos_flows_count}= Evaluate 4 * ${num_onus}
+ Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
+ ... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onos_flows_count}
+ # Verify VOLTHA Flows
# Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP
${olt_flows}= Evaluate 2 * ${num_onus} + 1
# Number of per ONU Flows equals 2 (one each for downstream and upstream)