M17 - Spirent - Verify IPv4 Unicast Streams Downstream

Test Objective

  • Purpose of this test is to verify OLT and ONU can handle double tagged traffic

Test Configuration

  • Test Setup as shown in Section – 7
  • Maple OLT and ONU is activated using VOLTHA
  • Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA

Test Procedure

  • On Spirent, configure double tagged traffic in downstream direction (1025,1025)
  • On Spirent, send untagged traffic in upstream direction
  • On the both ports capture traffic and verify the stream

Pass / Fail Criteria

  • Upstream:
    • configure on the Spirent side to send traffic with NO vlan
    • OLT and ONT will add 1025 ,1025 respectively (i.e. 1025,1025)
  • Downstream:
    • configure on the Spirent side to send traffic with 1025,1025
    • OLT will strip the 1025 and send traffic to corresponding ONT ( i.e. 1025 to ONT)