T19 - 10k and 20k ONU Ranging

Test Objective

  • Purpose of this test is to verify ONU can range with 10km and 20 KM distance

Test Configuration

  • Test Setup is as shown in earlier sections

Test Procedure

  • Register the ONU with the OLT across a 10KM fiber spool
  • Activate the OLT and ONU using VOLTHA
  • Confirm OLT and ONU have the oper_status of ACTIVE in VOLTHA
  • Register the ONU with the OLT across a 20KM fiber spool
  • Activate the OLT and ONU using VOLTHA
  • Confirm OLT and ONU have the oper_status of ACTIVE in VOLTHA
  • Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA and send traffic

Pass / Fail Criteria

  • OLT can range the ONU successfully with 10 KM distance
  • OLT can range the ONU successfully with 20 KM distance
  • Traffic flows successfully with 20 KM distance without any drops