M21 - 2000 byte Frames

Test Objective

  • Purpose of this test is to verify OLT and ONU can accept and forward traffic when frame size of 2000 bytes

Test Configuration

  • Test Setup as shown in Section – 7
  • Maple OLT and ONU is activated using VOLTHA
  • Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA

Test Procedure

  • Send data/unicast traffic with frame size of 2000 Bytes in upstream and downstream direction

Pass / Fail Criteria

  • OLT & ONU can accept and forward frames of size 2000 Bytes successfully