T25 - Traffic Recovers After ONU Reset (Best Effort)

Test Objective

  • Purpose of this test is to verify reset/reboot of ONU is able to recover the traffic on the ONU

Test Configuration

  • Test Setup as shown in Section – 7
  • Tibit OLT and ONU is activated using VOLTHA
  • Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA

Test Procedure

  • Now manually reset /reboot the ONU
  • Verify whether ONU ranges and traffic is restored successfully

Pass / Fail Criteria

  • Traffic should stop flowing when ONU is restarted
  • After ONU is up, traffic restores automatically on the ONU