M26 - Traffic Recovers After OLT Reset (Best Effort)
Test Objective
- Purpose of this test is to verify reset/reboot of ONU is able to recover the traffic on the ONU
Test Configuration
- Test Setup as shown in Section – 7
- Maple OLT and ONU is activated using VOLTHA
- Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA
Test Procedure
- Now reset /reboot the OLT
- Verify OLT is up, ONU ranges and traffic is restored successfully
Pass / Fail Criteria
- When OLT is up, ONU ranges back and traffic restores automatically on the ONU