M19 - 10k and 20k ONU Ranging
Test Objective
- Purpose of this test is to verify ONU can range with 10km and 20 KM distance
Test Configuration
- Test Setup as shown in Section – 7
Test Procedure
- Place the ONU Using 10KM fiber pool, Activate the OLT and ONU using VOLTHA
- Place the ONU Using 20KM fiber pool, Activate the OLT and ONU using VOLTHA
- Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA and send traffic
Pass / Fail Criteria
- OLT can range the ONU successfully with 10 KM distance
- OLT can range the ONU successfully with 20 KM distance
- Traffic flows successfully with 20 KM distance without any drops