T19 - 10k and 20k ONU Ranging
Test Objective
- Purpose of this test is to verify ONU can range with 10km and 20 KM distance
Test Configuration
- Test Setup is as shown in earlier sections
Test Procedure
- Register the ONU with the OLT across a 10KM fiber spool
- Activate the OLT and ONU using VOLTHA
- Confirm OLT and ONU have the oper_status of
ACTIVE
in VOLTHA - Register the ONU with the OLT across a 20KM fiber spool
- Activate the OLT and ONU using VOLTHA
- Confirm OLT and ONU have the oper_status of
ACTIVE
in VOLTHA - Provision HSIA/unicast service on the OLT and connected ONU from VOLTHA and send traffic
Pass / Fail Criteria
- OLT can range the ONU successfully with 10 KM distance
- OLT can range the ONU successfully with 20 KM distance
- Traffic flows successfully with 20 KM distance without any drops