| SPDX-FileCopyrightText: © 2020 Open Networking Foundation <support@opennetworking.org> |
| SPDX-License-Identifier: Apache-2.0 |
| |
| ============= |
| Bootstrapping |
| ============= |
| |
| OS Installation - Switches |
| ========================== |
| |
| .. note:: |
| |
| This part will be done automatically once we have a DHCP and HTTP server set up in the infrastructure. |
| For now, we need to download and install the ONL image manually. |
| |
| Install ONL with Docker |
| ----------------------- |
| First, enter **ONIE rescue mode**. |
| |
| Set up IP and route |
| ^^^^^^^^^^^^^^^^^^^ |
| .. code-block:: console |
| |
| # ip addr add 10.92.1.81/24 dev eth0 |
| # ip route add default via 10.92.1.1 |
| |
| - `10.92.1.81/24` should be replaced by the actual IP and subnet of the ONL. |
| - `10.92.1.1` should be replaced by the actual default gateway. |
| |
| Download and install ONL |
| ^^^^^^^^^^^^^^^^^^^^^^^^ |
| |
| .. code-block:: console |
| |
| # wget https://github.com/opennetworkinglab/OpenNetworkLinux/releases/download/v1.3.2/ONL-onf-ONLPv2_ONL-OS_2020-10-09.1741-f7428f2_AMD64_INSTALLED_INSTALLER |
| # sh ONL-onf-ONLPv2_ONL-OS_2020-10-09.1741-f7428f2_AMD64_INSTALLED_INSTALLER |
| |
| The switch will reboot automatically once the installer is done. |
| |
| .. note:: |
| |
| Alternatively, we can `scp` the ONL installer into ONIE manually. |
| |
| Setup BMC for remote console access |
| ----------------------------------- |
| Log in to the BMC from ONL by |
| |
| .. code-block:: console |
| |
| # ssh root@192.168.0.1 # pass: 0penBmc |
| |
| on `usb0` interface. |
| |
| Once you are in the BMC, run the following commands to setup IP and route (or offer a fixed IP with DHCP) |
| |
| .. code-block:: console |
| |
| # ip addr add 10.92.1.85/24 dev eth0 |
| # ip route add default via 10.92.1.1 |
| |
| - `10.92.1.85/24` should be replaced by the actual IP and subnet of the BMC. |
| Note that it should be different from the ONL IP. |
| - `10.92.1.1` should be replaced by the actual default gateway. |
| |
| BMC uses the same ethernet port as ONL management so you should give it an IP address in the same subnet. |
| BMC address will preserve during ONL reboot, but won’t be preserved during power outage. |
| |
| To log in to ONL console from BMC, run |
| |
| .. code-block:: console |
| |
| # /usr/local/bin/sol.sh |
| |
| If `sol.sh` is unresponsive, please try to restart the mainboard with |
| |
| .. code-block:: console |
| |
| # wedge_power.sh restart |
| |
| Setup network and host name for ONL |
| ----------------------------------- |
| |
| .. code-block:: console |
| |
| # hostnamectl set-hostname <host-name> |
| |
| # vim.tiny /etc/hosts # update accordingly |
| # cat /etc/hosts # example |
| 127.0.0.1 localhost |
| 10.92.1.81 menlo-staging-spine-1 |
| |
| # vim.tiny /etc/network/interfaces.d/ma1 # update accordingly |
| # cat /etc/network/interfaces.d/ma1 # example |
| auto ma1 |
| iface ma1 inet static |
| address 10.92.1.81 |
| netmask 255.255.255.0 |
| gateway 10.92.1.1 |
| dns-nameservers 8.8.8.8 |