| SPDX-FileCopyrightText: © 2020 Open Networking Foundation <support@opennetworking.org> |
| SPDX-License-Identifier: Apache-2.0 |
| |
| Hardware Installation |
| ===================== |
| |
| Hardware installation breaks down into a few steps: |
| |
| 1. `Planning`_ |
| 2. `Inventory`_ |
| 3. `Rackmount of Equipment`_ |
| 4. `Cabling and Network Topology`_ |
| 5. `Management Switch Bootstrap`_ |
| 6. `Management Server Bootstrap`_ |
| 7. `Server Software Bootstrap`_ |
| |
| Installation of the fabric switch hardware is covered in :ref:`OS Installation |
| - Switches <switch-install>`. |
| |
| Installation of the radio hardware is covered in :ref:`eNB Installation |
| <enb-installation>`. |
| |
| Planning |
| -------- |
| The planning of the network topology and devices, and required cabling |
| |
| Once planning is complete, equipment is ordered to match the plan. |
| |
| Network Cable Plan |
| """""""""""""""""" |
| |
| If a 2x2 TOST fabric is used it should be configured as a :doc:`Single-Stage |
| Leaf-Spine <trellis:supported-topology>`. |
| |
| - The links between each leaf and spine switch must be made up of two separate |
| cables. |
| |
| - Each compute server is dual-homed via a separate cable to two different leaf |
| switches (as in the "paired switches" diagrams). |
| |
| If only a single P4 switch is used, the :doc:`Simple |
| <trellis:supported-topology>` topology is used, with two connections from each |
| compute server to the single switch |
| |
| Additionally a non-fabric switch is required to provide a set of management |
| networks. This management switch is configured with multiple VLANs to separate |
| the management plane, fabric, and the out-of-band and lights out management |
| connections on the equipment. |
| |
| Device Naming |
| """"""""""""" |
| |
| Site Design and Bookkeeping |
| """"""""""""""""""""""""""" |
| |
| The following items need to be added to `NetBox |
| <https://netbox.readthedocs.io/en/stable>`_ to describe each edge site: |
| |
| 1. Add a Site for the edge (if one doesn't already exist), which has the |
| physical location and contact information for the edge. |
| |
| 2. Add Racks to the Site (if they don't already exist) |
| |
| 3. Add a Tenant for the edge (who owns/manages it), assigned to the ``Pronto`` |
| or ``Aether`` Tenant Group. |
| |
| 4. Add a VRF (Routing Table) for the edge site. |
| |
| 5. Add a VLAN Group to the edge site, which groups the site's VLANs and |
| prevents duplication. |
| |
| 6. Add VLANs for the edge site. These should be assigned a VLAN Group, the |
| Site, and Tenant. |
| |
| There can be multiple of the same VLAN in NetBox (VLANs are layer 2, and |
| local to the site), but not within the VLAN group. |
| |
| The minimal list of VLANs: |
| |
| * ADMIN 1 |
| * UPLINK 10 |
| * MGMT 800 |
| * FAB 801 |
| |
| If you have multiple deployments at a site using the same management server, |
| add additional VLANs incremented by 10 for the MGMT/FAB - for example: |
| |
| * DEVMGMT 810 |
| * DEVFAB 801 |
| |
| 7. Add IP Prefixes for the site. This should have the Tenant and VRF assigned. |
| |
| All edge IP prefixes fit into a ``/22`` sized block. |
| |
| The description of the Prefix contains the DNS suffix for all Devices that |
| have IP addresses within this Prefix. The full DNS names are generated by |
| combining the first ``<devname>`` component of the Device names with this |
| suffix. |
| |
| An examples using the ``10.0.0.0/22`` block. There are 4 edge |
| prefixes, with the following purposes: |
| |
| * ``10.0.0.0/25`` |
| |
| * Has the Server BMC/LOM and Management Switch |
| * Assign the ADMIN 1 VLAN |
| * Set the description to ``admin.<deployment>.<site>.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * ``10.0.0.128/25`` |
| |
| * Has the Server Management plane, Fabric Switch Management/BMC |
| * Assign MGMT 800 VLAN |
| * Set the description to ``<deployment>.<site>.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * ``10.0.1.0/25`` |
| |
| * IP addresses of the qsfp0 port of the Compute Nodes to Fabric switches, devices |
| connected to the Fabric like the eNB |
| * Assign FAB 801 VLAN |
| * Set the description to ``fab1.<deployment>.<site>.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * ``10.0.1.128/25`` |
| |
| * IP addresses of the qsfp1 port of the Compute Nodes to fabric switches |
| * Assign FAB 801 VLAN |
| * Set the description to ``fab2.<deployment>.<site>.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| Additionally, these edge prefixes are used for Kubernetes but don't need to |
| be created in NetBox: |
| |
| * ``10.0.2.0/24`` |
| |
| * Kubernetes Pod IP's |
| |
| * ``10.0.3.0/24`` |
| |
| * Kubernetes Cluster IP's |
| |
| 8. Add Devices to the site, for each piece of equipment. These are named with a |
| scheme similar to the DNS names used for the pod, given in this format:: |
| |
| <devname>.<deployment>.<site> |
| |
| Examples:: |
| |
| mgmtserver1.ops1.tucson |
| node1.stage1.menlo |
| |
| Note that these names are transformed into DNS names using the Prefixes, and |
| may have additional components - ``admin`` or ``fabric`` may be added after |
| the ``<devname>`` for devices on those networks. |
| |
| Set the following fields when creating a device: |
| |
| * Site |
| * Tenant |
| * Rack & Rack Position |
| * Serial number |
| |
| If a specific Device Type doesn't exist for the device, it must be created, |
| which is detailed in the NetBox documentation, or ask the OPs team for help. |
| |
| 9. Add Services to the management server: |
| |
| * name: ``dns`` |
| protocol: UDP |
| port: 53 |
| |
| * name: ``tftp`` |
| protocol: UDP |
| port: 69 |
| |
| These are used by the DHCP and DNS config to know which servers offer a |
| dns service and tftp. |
| |
| 10. Set the MAC address for the physical interfaces on the device. |
| |
| You may also need to add physical network interfaces if aren't already |
| created by the Device Type. An example would be if additional add-in |
| network cards were installed. |
| |
| 11. Add any virtual interfaces to the Devices. When creating a virtual |
| interface, it should have it's ``label`` field set to the physical network |
| interface that it is assigned |
| |
| These are needed are two cases for the Pronto deployment: |
| |
| 1. On the Management Server, there should bet (at least) two VLAN |
| interfaces created attached to the ``eno2`` network port, which |
| are used to provide connectivity to the management plane and fabric. |
| These should be named ``<name of vlan><vlan ID>``, so the MGMT 800 VLAN |
| would become a virtual interface named ``mgmt800``, with the label |
| ``eno2``. |
| |
| 2. On the Fabric switches, the ``eth0`` port is shared between the OpenBMC |
| interface and the ONIE/ONL installation. Add a ``bmc`` virtual |
| interface with a label of ``eth0`` on each fabric switch, and check the |
| ``OOB Management`` checkbox. |
| |
| 12. Create IP addresses for the physical and virtual interfaces. These should |
| have the Tenant and VRF set. |
| |
| The Management Server should always have the first IP address in each |
| range, and they should be incremental, in this order. Examples are given as |
| if there was a single instance of each device - adding additional devices |
| would increment the later IP addresses. |
| |
| * Management Server |
| |
| * ``eno1`` - site provided public IP address, or blank if DHCP |
| provided |
| |
| * ``eno2`` - 10.0.0.1/25 (first of ADMIN) - set as primary IP |
| * ``bmc`` - 10.0.0.2/25 (next of ADMIN) |
| * ``mgmt800`` - 10.0.0.129/25 (first of MGMT) |
| * ``fab801`` - 10.0.1.1/25 (first of FAB) |
| |
| * Management Switch |
| |
| * ``gbe1`` - 10.0.0.3/25 (next of ADMIN) - set as primary IP |
| |
| * Fabric Switch |
| |
| * ``eth0`` - 10.0.0.130/25 (next of MGMT), set as primary IP |
| * ``bmc`` - 10.0.0.131/25 |
| |
| * Compute Server |
| |
| * ``eth0`` - 10.0.0.132/25 (next of MGMT), set as primary IP |
| * ``bmc`` - 10.0.0.4/25 (next of ADMIN) |
| * ``qsfp0`` - 10.0.1.2/25 (next of FAB) |
| * ``qsfp1`` - 10.0.1.3/25 |
| |
| * Other Fabric devices (eNB, etc.) |
| |
| * ``eth0`` or other primary interface - 10.0.1.4/25 (next of FAB) |
| |
| 13. Add DHCP ranges to the IP Prefixes for IP's that aren't reserved. These are |
| done like any other IP Address, but with the ``Status`` field is set to |
| ``DHCP``, and they'll consume the entire range of IP addresses given in the |
| CIDR mask. |
| |
| For example ``10.0.0.32/27`` as a DHCP block would take up 1/4 of the ADMIN |
| prefix. |
| |
| 14. Add Cables between physical interfaces on the devices |
| |
| TODO: Explain the cabling topology |
| |
| Hardware |
| """""""" |
| |
| Fabric Switches |
| ''''''''''''''' |
| |
| Pronto currently uses fabric switches based on the Intel (was Barefoot) Tofino |
| chipset. There are multiple variants of this switching chipset, with different |
| speeds and capabilities. |
| |
| The specific hardware models in use in Pronto: |
| |
| * `EdgeCore Wedge100BF-32X |
| <https://www.edge-core.com/productsInfo.php?cls=1&cls2=180&cls3=181&id=335>`_ |
| - a "Dual Pipe" chipset variant, used for the Spine switches |
| |
| * `EdgeCore Wedge100BF-32QS |
| <https://www.edge-core.com/productsInfo.php?cls=1&cls2=180&cls3=181&id=770>`_ |
| - a "Quad Pipe" chipset variant, used for the Leaf switches |
| |
| Compute Servers |
| |
| These servers run Kubernetes and edge applications. |
| |
| The requirements for these servers: |
| |
| * AMD64 (aka x86-64) architecture |
| * Sufficient resources to run Kubernetes |
| * Two 40GbE or 100GbE Ethernet connections to the fabric switches |
| * One management 1GbE port |
| |
| The specific hardware models in use in Pronto: |
| |
| * `Supermicro 6019U-TRTP2 |
| <https://www.supermicro.com/en/products/system/1U/6019/SYS-6019U-TRTP2.cfm>`_ |
| 1U server |
| |
| * `Supermicro 6029U-TR4 |
| <https://www.supermicro.com/en/products/system/2U/6029/SYS-6029U-TR4.cfm>`_ |
| 2U server |
| |
| These servers are configured with: |
| |
| * 2x `Intel Xeon 5220R CPUs |
| <https://ark.intel.com/content/www/us/en/ark/products/199354/intel-xeon-gold-5220r-processor-35-75m-cache-2-20-ghz.html>`_, |
| each with 24 cores, 48 threads |
| * 384GB of DDR4 Memory, made up with 12x 16GB ECC DIMMs |
| * 2TB of nVME Flash Storage |
| * 2x 6TB SATA Disk storage |
| * 2x 40GbE ports using an XL710QDA2 NIC |
| |
| The 1U servers additionally have: |
| |
| - 2x 1GbE copper network ports |
| - 2x 10GbE SFP+ network ports |
| |
| The 2U servers have: |
| |
| - 4x 1GbE copper network ports |
| |
| Management Server |
| ''''''''''''''''' |
| |
| One management server is required, which must have at least two 1GbE network |
| ports, and runs a variety of network services to support the edge. |
| |
| The model used in Pronto is a `Supermicro 5019D-FTN4 |
| <https://www.supermicro.com/en/Aplus/system/Embedded/AS-5019D-FTN4.cfm>`_ |
| |
| Which is configured with: |
| |
| * AMD Epyc 3251 CPU with 8 cores, 16 threads |
| * 32GB of DDR4 memory, in 2x 16GB ECC DIMMs |
| * 1TB of nVME Flash storage |
| * 4x 1GbE copper network ports |
| |
| Management Switch |
| ''''''''''''''''' |
| |
| This switch connects the configuration interfaces and management networks on |
| all the servers and switches together. |
| |
| In the Pronto deployment this hardware is a `HP/Aruba 2540 Series JL356A |
| <https://www.arubanetworks.com/products/switches/access/2540-series/>`_. |
| |
| Inventory |
| --------- |
| |
| Once equipment arrives, any device needs to be recorded in inventory if it: |
| |
| 1. Connects to the network (has a MAC address) |
| 2. Has a serial number |
| 3. Isn't a subcomponent (disk, add-in card, linecard, etc.) of a larger device. |
| |
| The following information should be recorded for every device: |
| |
| - Manufacturer |
| - Model |
| - Serial Number |
| - MAC address (for the primary and any management/BMC/IPMI interfaces) |
| |
| This information should be be added to the corresponding Devices ONF NetBox |
| instance. The accuracy of this information is very important as it is used in |
| bootstrapping the systems. |
| |
| Once inventory has been completed, let the Infra team know, and the pxeboot |
| configuration will be generated to have the OS preseed files corresponding to the |
| new servers based on their serial numbers. |
| |
| Rackmount of Equipment |
| ---------------------- |
| |
| Most of the Pronto equipment is in a 19" rackmount form factor. |
| |
| Guidelines for mounting this equipment: |
| |
| - The EdgeCore Wedge Switches have a front-to-back (aka "port-to-power") fan |
| configuration, so hot air exhaust is out the back of the switch near the |
| power inlets, away from the 32 QSFP network ports on the front of the switch. |
| |
| - The full-depth 1U and 2U Supermicro servers also have front-to-back airflow |
| but have most of their ports on the rear of the device. |
| |
| - Airflow through the rack should be in one direction to avoid heat being |
| pulled from one device into another. This means that to connect the QSFP |
| network ports from the servers to the switches, cabling should be routed |
| through the rack from front (switch) to back (server). |
| |
| - The short-depth management HP Switch and 1U Supermicro servers should be |
| mounted to the rear of the rack. They both don't generate an appreciable |
| amount of heat, so the airflow direction isn't a significant factor in |
| racking them. |
| |
| Cabling and Network Topology |
| ---------------------------- |
| |
| TODO: Add diagrams of network here, and cabling plan |
| |
| Management Switch Bootstrap |
| --------------------------- |
| |
| TODO: Add instructions for bootstrapping management switch, from document that |
| has the linked config file. |
| |
| Server Software Bootstrap |
| ------------------------- |
| |
| Management Server Bootstrap |
| """"""""""""""""""""""""""" |
| |
| The management server is bootstrapped into a customized version of the standard |
| Ubuntu 18.04 OS installer. |
| |
| The `iPXE boot firmware <https://ipxe.org/>`_. is used to start this process |
| and is built using the steps detailed in the `ipxe-build |
| <https://gerrit.opencord.org/plugins/gitiles/ipxe-build>`_. repo, which |
| generates both USB and PXE chainloadable boot images. |
| |
| Once a system has been started using these images started, these images will |
| download a customized script from an external webserver to continue the boot |
| process. This iPXE to webserver connection is secured with mutual TLS |
| authentication, enforced by the nginx webserver. |
| |
| The iPXE scripts are created by the `pxeboot |
| <https://gerrit.opencord.org/plugins/gitiles/ansible/role/pxeboot>`_ role, |
| which creates both a boot menu, downloads the appropriate binaries for |
| bootstrapping an OS installation, and creates per-node installation preseed files. |
| |
| The preseed files contain configuration steps to install the OS from the |
| upstream Ubuntu repos, as well as customization of packages and creating the |
| ``onfadmin`` user. |
| |
| TODO: convert instructions for bootstrapping the management server with iPXE here. |
| |
| Once the OS is installed on the management server, Ansible is used to remotely |
| install software on the management server. |
| |
| To checkout the ONF ansible repo and enter the virtualenv with the tooling:: |
| |
| mkdir infra |
| cd infra |
| repo init -u ssh://<your gerrit username>@gerrit.opencord.org:29418/infra-manifest |
| repo sync |
| cd ansible |
| make galaxy |
| source venv_onfansible/bin/activate |
| |
| Obtain the ``undionly.kpxe`` iPXE artifact for bootstrapping the compute |
| servers, and put it in the ``files`` directory. |
| |
| Next, create an inventory file to access the NetBox API. An example is given |
| in ``inventory/example-netbox.yml`` - duplicate this file and modify it. Fill |
| in the ``api_endpoint`` address and ``token`` with an API key you get out of |
| the NetBox instance. List the IP Prefixes used by the site in the |
| ``ip_prefixes`` list. |
| |
| Next, run the ``scripts/netbox_edgeconfig.py`` to generate a host_vars file for |
| the management server. Assuming that the management server in the edge is |
| named ``mgmtserver1.stage1.menlo``, you'd run:: |
| |
| python scripts/netbox_edgeconfig.py inventory/my-netbox.yml > inventory/host_vars/mgmtserver1.stage1.menlo.yml |
| |
| One manual change needs to be made to this output - edit the |
| ``inventory/host_vars/mgmtserver1.stage1.menlo.yml`` file and add the following |
| to the bottom of the file, replacing the IP addresses with the ones that the |
| management server is configured with on each VLAN. This configures the `netplan |
| <https://netplan.io>`_ on the management server, and will be automated away |
| soon:: |
| |
| # added manually |
| netprep_netplan: |
| ethernets: |
| eno2: |
| addresses: |
| - 10.0.0.1/25 |
| vlans: |
| mgmt800: |
| id: 800 |
| link: eno2 |
| addresses: |
| - 10.0.0.129/25 |
| fabr801: |
| id: 801 |
| link: eno2 |
| addresses: |
| - 10.0.1.1/25 |
| |
| Create an inventory file for the management server in |
| ``inventory/menlo-staging.ini`` which contains:: |
| |
| [mgmt] |
| mgmtserver1.stage1.menlo ansible_host=<public ip address> ansible_user="onfadmin" ansible_become_password=<password> |
| |
| Then, to configure a management server, run:: |
| |
| ansible-playbook -i inventory/menlo-staging.ini playbooks/aethermgmt-playbook.yml |
| |
| This installs software with the following functionality: |
| |
| - VLANs on second Ethernet port to provide connectivity to the rest of the pod. |
| - Firewall with NAT for routing traffic |
| - DHCP and TFTP for bootstrapping servers and switches |
| - DNS for host naming and identification |
| - HTTP server for serving files used for bootstrapping switches |
| |
| Compute Server Bootstrap |
| """""""""""""""""""""""" |
| |
| Once the management server has finished installation, it will be set to offer |
| the same iPXE bootstrap file to the computer. |
| |
| Each node will be booted, and when iPXE loads select the ``Ubuntu 18.04 |
| Installer (fully automatic)`` option. |
| |
| The nodes can be controlled remotely via their BMC management interfaces - if |
| the BMC is at ``10.0.0.3`` a remote user can SSH into them with:: |
| |
| ssh -L 2443:10.0.0.3:443 onfadmin@<mgmt server ip> |
| |
| And then use their web browser to access the BMC at:: |
| |
| https://localhost:2443 |
| |
| The default BMC credentials for the Pronto nodes are:: |
| |
| login: ADMIN |
| password: Admin123 |
| |
| Once these nodes are brought up, the installation can continue. |