| .. |
| SPDX-FileCopyrightText: © 2020 Open Networking Foundation <support@opennetworking.org> |
| SPDX-License-Identifier: Apache-2.0 |
| |
| Site Planning |
| ============= |
| |
| Planning an edge site generally happens in three phases: |
| |
| 1. A BoM of equipment is defined, then purchased. |
| |
| 2. The equipment is delivered and inventoried. This usually is done by the edge |
| site, and involves collecting information like the serial numbers, MAC |
| addresses and other details about the specific pieces of equipment being |
| installed. |
| |
| 3. ONF Staff enters this information into Netbox, which is used to generate |
| configuration for the edge site and document the configuration. |
| |
| This document describes the 3rd phase, and exists primarily as a reference for |
| ONF Staff. |
| |
| Site Design in Netbox |
| --------------------- |
| |
| The Aether project uses Netbox as source of truth, and the automation script |
| uses the Netbox API to create input files for Ansible Playbooks which are used |
| to configure each site. |
| |
| Once the hardware has been ordered, the installation can be planned. The |
| following information needs to be added to `NetBox |
| <https://netbox.readthedocs.io/en/stable>`_ to describe each edge site: |
| |
| .. note:: |
| The **bold** words represent the models in Netbox. |
| |
| 1. Add a **Site** for the edge (if one doesn't already exist), which has the |
| physical location and contact information for the Aether Edge. |
| |
| 2. Add equipment Racks to the Site (if they don't already exist). |
| |
| 3. Add a **Tenant** for the edge (who owns/manages it), assigned to the ``Pronto`` |
| or ``Aether`` Tenant Group. |
| |
| 4. Add a **VRF** (Routing Table) for the edge site. This is usually just the name |
| of the site. Make sure that ``Enforce unique space`` is checked, so that IP |
| addresses within the VRF are forced to be unique, and that the Tenant Group |
| and Tenant are set. |
| |
| 5. Add a **VLAN Group** to the edge site, which groups the site's VLANs and |
| requires that they have a unique VLAN number. |
| |
| 6. Add **VLANs** for the edge site. These VLAN objects should be assigned a VLAN |
| Group, a Site, and a Tenant. |
| |
| There can be multiple of the same VLAN in NetBox (VLANs are layer 2, and |
| local to the site), but not within the VLAN group. |
| |
| The minimal list of VLANs: |
| |
| * ADMIN 1 |
| * UPLINK 10 |
| * MGMT 800 |
| * FAB 801 |
| |
| If you have multiple deployments at a site using the same management router, |
| add additional VLANs incremented by 10 for the MGMT/FAB - for example, you |
| can create the VLANs for development server as follows: |
| |
| * DEVMGMT 810 |
| * DEVFAB 801 |
| |
| 7. Add IP **Prefixes** for the site. This should have the Tenant and VRF assigned. |
| |
| All IP prefixes of Aether Edge will fit into a ``/22`` sized block. |
| |
| The Prefix description field is used to create DNS names for IP addresses in the Prefix. |
| The DNS A records for each IP address start with the name of the Device, and end with |
| the Prefix description. |
| |
| For example, if we have a management router named ``mgmtserver`` in **Prefix** |
| ``prod1.menlo.aetherproject.net``, and the management router's DNS name will be |
| ``mgmtserver.prod1.menlo.aetherproject.net``. |
| |
| Here is an example using the ``10.0.0.0/22`` block. Let's name our deployment |
| as "prod1", and name our site as "menlo". Then we define 4 **Prefixes** |
| with different purposes. |
| |
| .. note:: |
| NOTE: You should replace the **prod1** and **menlo** to your deployment name and |
| site name. |
| .. |
| |
| * ADMIN Prefix - ``10.0.0.0/25`` (for Lights-out management) |
| |
| * Has the Server BMC/LOM and Management Switch |
| * Assign with the ADMIN 1 VLAN |
| * Set the description to ``admin.prod1.menlo.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * MGMT Prefix - ``10.0.0.128/25`` (for infrastructure control plane) |
| |
| * Has the Server Management plane, Fabric Switch Management/BMC |
| * Assign with MGMT 800 VLAN |
| * Set the description to ``prod1.menlo.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * FABRIC1 Prefix - ``10.0.1.0/25`` |
| |
| * Compute Nodes' qsfp0 port which connects to Fabric switches, |
| and other devices (eNB, ...) connect to the Fabric switches. |
| * Assign with FAB 801 VLAN |
| * Set the description to ``fab1.prod1.menlo.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| * FABRIC2 Prefix - ``10.0.1.128/25`` |
| |
| * Compute Nodes' qsfp1 port which connects to Fabric switches |
| * Assign FAB 801 VLAN |
| * Set the description to ``fab2.prod1.menlo.aetherproject.net`` (or |
| ``prontoproject.net``). |
| |
| And we will have an additional parent prefix includes 2 FABRIC Prefix. |
| |
| * ``10.0.1.0/24`` |
| |
| * This is used to configure the correct routes, DNS, and TFTP servers |
| provided by DHCP to the equipment that is connected to the fabric |
| leaf switch that the management router (which provides those |
| services) is not connected to. |
| |
| Additionally, these edge prefixes are used for Kubernetes but don't need to |
| be created in NetBox: |
| |
| * ``10.0.2.0/24`` |
| |
| * Kubernetes Pod IP's |
| |
| * ``10.0.3.0/24`` |
| |
| * Kubernetes Cluster IP's |
| |
| 8. Add **Devices** to the site, for each piece of equipment. These are named with a |
| scheme similar to the DNS names used for the pod, given in this format:: |
| |
| <devname>.<deployment>.<site> |
| |
| Examples:: |
| |
| mgmtserver1.ops1.tucson |
| node1.stage1.menlo |
| |
| Note that these names are transformed into DNS names using the Prefixes, and |
| may have additional components - ``admin`` or ``fabric`` may be added after |
| the ``<devname>`` for devices on those networks. |
| |
| Set the following fields when creating a device: |
| |
| * Site |
| * Tenant |
| * Rack & Rack Position |
| * Serial number |
| |
| If a specific Device Type doesn't exist for the device, it must be created, |
| which is detailed in the NetBox documentation, or ask the OPs team for help. |
| |
| See `Rackmount of Equipment`_ below for guidance on how equipment should be |
| mounted in the Rack. |
| |
| 9. Add **Service** to the management router: |
| |
| * name: ``dns`` |
| protocol: UDP |
| port: 53 |
| |
| * name: ``tftp`` |
| protocol: UDP |
| port: 69 |
| |
| These are used by the DHCP and DNS config to know which servers offer |
| DNS or TFTP service. |
| |
| 10. Set the MAC address for the physical interfaces on the device. |
| |
| You may also need to add physical network interfaces if they aren't already |
| created by the Device Type. An example would be if additional add-in |
| network cards were installed. |
| |
| 11. Add any virtual interfaces to the **Devices**. When creating a virtual |
| interface, it should have it's ``label`` field set to the name of the |
| physical interface that it is assigned |
| |
| These are needed for two cases of the Pronto deployment: |
| |
| 1. On the management router, there should bet (at least) two VLAN |
| interfaces created attached to the ``eno2`` network port, which |
| are used to provide connectivity to the management plane and fabric. |
| These interfaces should be named ``<name of vlan><vlan ID>``, so the |
| MGMT 800 VLAN would become a virtual interface named ``mgmt800``, with |
| the label ``eno2``. |
| |
| 2. On the Fabric switches, the ``eth0`` port is shared between the OpenBMC |
| interface and the ONIE/ONL installation. Add a ``bmc`` virtual |
| interface with a label of ``eth0`` on each fabric switch, and have the |
| ``OOB Management`` checkbox checked. |
| |
| 12. Create **IP addresses** for the physical and virtual interfaces. These should |
| have the Tenant and VRF set. |
| |
| The management router should always have the first IP address in each |
| range, and they should be incremental, in this order. Examples are given as |
| if there was a single instance of each device - adding additional devices |
| would increment the later IP addresses. |
| |
| * management router |
| |
| * ``eno1`` - site provided public IP address, or blank if DHCP |
| provided |
| |
| * ``eno2`` - 10.0.0.1/25 (first of ADMIN) - set as primary IP |
| * ``bmc`` - 10.0.0.2/25 (next of ADMIN) |
| * ``mgmt800`` - 10.0.0.129/25 (first of MGMT) |
| * ``fab801`` - 10.0.1.1/25 (first of FAB) |
| |
| * Management Switch |
| |
| * ``gbe1`` - 10.0.0.3/25 (next of ADMIN) - set as primary IP |
| |
| * Fabric Switch |
| |
| * ``eth0`` - 10.0.0.130/25 (next of MGMT), set as primary IP |
| * ``bmc`` - 10.0.0.131/25 |
| |
| * Compute Server |
| |
| * ``eth0`` - 10.0.0.132/25 (next of MGMT), set as primary IP |
| * ``bmc`` - 10.0.0.4/25 (next of ADMIN) |
| * ``qsfp0`` - 10.0.1.2/25 (next of FAB) |
| * ``qsfp1`` - 10.0.1.3/25 |
| |
| * Other Fabric devices (eNB, etc.) |
| |
| * ``eth0`` or other primary interface - 10.0.1.4/25 (next of FAB) |
| |
| 13. Add **IP address** to the **Prefix** to represent reserved DHCP ranges. |
| We use a single IP address which ``Status`` is set to ``DHCP`` to stand |
| for the DHCP range, the DHCP server will consume the entire range of IP |
| address in the CIDR mask (includes first and last IP addresses). |
| |
| For example, IP ``10.0.0.32/27`` with ``DHCP`` status in Prefix |
| ``10.0.0.0/25``, the IP will be a DHCP block, and allocate IP address from |
| ``10.0.0.32`` to ``10.0.0.63``. |
| |
| 14. Add **IP address** to the **Prefix** to represent route IP reservations for |
| both Fabric prefixes. These are IP addresses used by ONOS to route traffic |
| to the other leaf, and have the following attributes: |
| |
| - Have the last usable address in range (in the ``/25`` fabric examples |
| above, these would be ``10.0.1.126/25`` and ``10.0.1.254/25``) |
| |
| - Have a ``Status`` of ``Reserved``, and the VRF, Tenant Group, and Tenant |
| set. |
| |
| - The Description must start with the word ``router``, such as: ``router |
| for leaf1 Fabric`` |
| |
| - A custom field named ``RFC3442 Routes`` is set to the CIDR IP address of |
| the opposite leaf - if the leaf's prefix is ``10.0.1.0/25`` and the |
| router IP is ``10.0.1.126/25`` then ``RFC3442 Routes`` should be set to |
| ``10.0.1.128\25`` (and the reverse - on ``10.0.1.254/25`` the ``RFC3442 |
| Routes`` would be set to be ``10.0.1.0/25``). This creates an `RFC3442 |
| Classless Static Route Option <https://datatracker.ietf.org/doc/html/rfc3442>`_ |
| for the subnet in DHCP. |
| |
| 15. Add Cables between physical interfaces on the devices |
| |
| The topology needs to match the logical diagram presented in the |
| :ref:`Production Environments <edge_deployment/overview:Production |
| Environments>`. Note that many of the management interfaces need to be |
| located either on the MGMT or ADMIN VLANs, and the management switch is |
| used to provide that separation. |
| |
| Rackmount of Equipment |
| ---------------------- |
| |
| Most of the switch and server equipment used for Aether is available in the 19" |
| rackmount form factor, but care needs to be taken in mounting this equipment to |
| ensure proper airflow. Please follow these guidelines: |
| |
| - The EdgeCore Wedge Switches have a front-to-back (aka "port-to-power") fan |
| configuration, so hot air exhaust is out the back of the switch near the |
| power inlets, away from the 32 QSFP network ports on the front of the switch. |
| |
| - The full-depth servers (such as the 1U and 2U Supermicro servers used in |
| Pronto) also have front-to-back airflow but have most of their ports on the |
| rear of the device. |
| |
| - Airflow through the rack should be in one direction to avoid heat being |
| pulled from one device into another. This means that to connect the QSFP |
| network ports from the servers to the switches, cabling should be routed |
| through the rack from front (switch) to back (server). Empty rack spaces |
| should be reserved for this purpose. |
| |
| - The short-depth management switches and management routers should be mounted |
| on the rear of the rack. They don't generate an appreciable amount of heat, |
| so the airflow direction isn't a significant factor in racking them. |
| |
| Inventory |
| --------- |
| |
| Once equipment arrives, any device needs to be recorded in inventory if it: |
| |
| 1. Connects to the network (has a MAC address) |
| 2. Has a serial number |
| 3. Isn't a subcomponent (disk, add-in card, linecard, etc.) of a larger device. |
| |
| The following information should be recorded for every device: |
| |
| - Manufacturer |
| - Model |
| - Serial Number |
| - MAC address (for the primary and any management/BMC/IPMI interfaces) |
| |
| This information should be be added to the corresponding Devices within the ONF |
| NetBox instance. The accuracy of this information is very important as it is |
| used in bootstrapping the compute systems, which is currently done by Serial |
| Number, as reported to iPXE by SMBIOS. |
| |
| Once inventory has been completed, let the Infra team know, and the pxeboot |
| configuration will be generated to have the OS preseed files corresponding to the |
| new servers based on their serial numbers. |